background image

 

 

MAINTENANCE 

The  following  maintenance  operations  are  to  be  performed 
solely  by  trained  personnel,  able  to  perform  the  specified 
operations  safely.  When  possible,  the  machine  should  be 
powered off, the power cord unplugged and the compressed 
air supply disconnected. 

Warning! After powering off the machine, some of its inner parts 
remain live for several minutes (power capacitors). Wait at least 
5  minutes  before  performing  maintenance  inside  the  Vulcan 
ADU. 

 

ORDINARY MAINTENANCE 

GENERAL INFORMATION 

  Check the cleanliness of the heating tool's contact surfaces. If 

necessary, clean it with a soft cloth. 

  Check  the  cleanliness  of  the  infrared  lamp  glass  and,  if 

necessary, clean it with isopropyl alcohol and a soft cloth. 

  Keep  the  machine  clean.  Do  not  use  water  jets  to  clean  the 

machine  as  they  could  penetrate  inside.  Also  avoid  using 
strong  solvents,  thinners  or  gasoline  that  could  damage  the 
paint or the machine's plastic parts.  

  Clean  the  control  unit's  screen  using  a  dry  soft  cloth;  do  not 

use  water,  solvents,  alcohol  or  abrasive  cloths.  Limit  the 
exposure of the control panel to direct sunlight. 

 

ELECTRICAL CIRCUIT 

  You  should  frequently  check  the  condition  of  the  power  cord, 

the  plug  and  the  heating  tool  connecting  cables.  Replace  the 
power cord if you notice any cracks, cuts, scrapes, etc. 

  Make  sure  the  machine  is  connected  to  the  protective 

conductor and that the ground wire, both inside the power cord 
and the heating tool connecting cable, is not interrupted. 

  Periodically check the ground efficiency of the system. 

 

COOLING CIRCUIT 

  Keep  the  water  level  in  the  chiller 

within  the  “normal”  water 

level. 

  Clean  the  chiller  heat  exchanger,  Item  CHH5480,  using 

compressed air, on a regular basis. 

  Check that  slag/waste of any kind does not deposit inside the 

tank and hoses, otherwise remove and wash properly. 

WARNING:  do  not  keep  the  machine  in  places  where  the 
coolant could FREEZE. 

If you have to store the machine in a place where the aforesaid 
risk subsists, be sure to use an appropriate amount of antifreeze 
otherwise empty the cooling circuit completely. 
 

EXTRAORDINARY MAINTENANCE 

Only  specialized  technicians  are  allowed  to  perform 
interventions inside the machine. 

The  machine  is  equipped  with  a  thermostatic  safety  device.  If  it 
overheats, the following message is displayed: 

TEMP 

Do not power off the machine but let it cool down. This message 
clears automatically once the machine has cooled.  

The control unit's internal memory is powered by a lithium battery 
type  CR2032.  Replace  the  battery  in  case  of  a  memory 
malfunction.  Perform  the  replacement  after  unplugging  the 
power cord and be sure to use only a similar battery. 

 

 

 

 

 

 

 

 

Summary of Contents for Vulcan ADU CHH5402

Page 1: ...TROLLEY ITEM CHH5404 GENERATOR ITEM CHH5402 CHILLER ITEM CHH5403 ITEM CHH5408 ITEM CHH5409 CHIEF Automotive Technologies 996 Industrial Drive Madison IN 47250 Phone 800 445 9262 Fax 866 275 0173 EMAIL salesorders chiefautomotive com DOCUMENT NUMBER IN20784 EDITION 09 29 2016 ...

Page 2: ...ES 4 OPTIONS 4 TECHNICAL SPECIFICATIONS 4 GENERAL DESCRIPTION 5 SAFETY REQUIREMENTS 5 INSTALLATION 6 ASSEMBLY 6 COOLING SYSTEM 6 ELECTRIC INSTALLATION 6 WORK 7 PRELIMINARY CHECKS 7 PROGRAMMING 7 PROCESS 8 DESCRIPTION 8 MAINTENANCE 9 ORDINARY MAINTENANCE 9 EXTRAORDINARY MAINTENANCE 9 SERVICE AND WARRANTY 10 DISPOSAL 10 ...

Page 3: ...facturer Any changes even though slight are prohibited because they may compromise machine safety and shall void the machine s EC certification The purpose of this machine consists in repair work at car body shops using infrared heating to remove the panels glued to the inside of a motor vehicle This machine is not suitable for production work CHIEF Automotive Technologies is not responsible for a...

Page 4: ...IP21 IP21 IP21 Chiller cooling system capacity l Generator weight Chiller cooling lbs Kg 57 26 57 26 57 26 57 26 Lamp weight Lamp art CHH5408 lbs Kg 7 3 7 3 7 3 7 3 CONNECTION DATA Power cable Length Core section m mm2 10 6 10 6 10 6 10 6 Required distribution system cables extension cords Total L 15 m Total L 30 m mm2 mm2 6 10 6 10 6 10 6 10 Required line protection Plug Delayed fuses aM A A 32 3...

Page 5: ...TALLATION chapter Experienced personnel should carry out the job The machine should be adjusted solely by personnel authorized to do so Since machine adjustments affect operational safety whoever performs said adjustments must possess the required skill Carefully follow the instructions provided in the WORK paragraph It is forbidden for more than one person to work on this machine at a time Prohib...

Page 6: ...o 3 COOLING SYSTEM In order to cool the machine adequately it is equipped with a chiller that maintains the water in the cooling circuit at a temperature of 68 F This machine cannot be used if connected to a heat exchanger Fill the tank using only a mixture of water and antifreeze liquid for car radiators The antifreeze liquid is necessary for its anti corrosive properties Use only antifreeze liqu...

Page 7: ...he Vulcan ADU will modulate power so that the object to be heated will not exceed the temperature set on the control unit The profile mode generates a temperature profile that varies over time and contains 5 different temperature values at the most Heating that varies according to a thermal profile is useful to reduce paint drying time or the polymerization time of structural adhesives Drying or a...

Page 8: ...the process the display shows the temperature values reached by the surface to be heated and the power and set point temperature used To avoid performing low quality work it is advisable to adhere to the following recommendations The glass of the lamp must always be clean When the process is finished power off the machine unplug the electrical plug and shut off the compressed air supply Store the ...

Page 9: ...ecting cables Replace the power cord if you notice any cracks cuts scrapes etc Make sure the machine is connected to the protective conductor and that the ground wire both inside the power cord and the heating tool connecting cable is not interrupted Periodically check the ground efficiency of the system COOLING CIRCUIT Keep the water level in the chiller within the normal water level Clean the ch...

Page 10: ...th your fingers Since the bulb should not be touched with your fingers used clean gloves during this operation but if you mistakenly touch the lamps before installing them be sure to clean them using isopropyl alcohol 12 Reconnect the electrical connection cables of the infrared lamp by shortening them as required 13 Refit the latch no 8 14 Refit the two no 5 Allen screws of latch no 8 15 Refit th...

Page 11: ...11 TECHNICAL DOCUMENTATION DRAWINGS AND TABLES Fig 1 Dimensions ...

Page 12: ...12 ...

Page 13: ...13 ...

Page 14: ...14 ...

Page 15: ...15 Fig 2 Trolley assembly ...

Page 16: ...16 Fig 3 Replacing the glass and or lamp ...

Page 17: ...17 Fig 4 Control unit assembly ...

Page 18: ...18 ...

Page 19: ...19 Fig 4 Wiring Diagram ...

Page 20: ...20 ...

Page 21: ...21 ...

Page 22: ...22 Chief Automotive Technologies 999 industrial Drive madison IN 47250 Phone 800 445 9262 Fax 866 275 0173 EMAIL salesorders chiefautomotive com ...

Reviews: