Installation Instructions

CM6SV65 and 83

9

Status Light Codes

There is a light on the front of the mechanism motor box that
will tell through its pattern of flashes and colors what the
mechanism is doing.

Figure 10

Normal Doors At Rest -

The Status Light will be on steady

green.

Normal Run Motion of Doors

- The Status Light will flash in

groups of 2 green followed  by  a pause. In normal run motion
the doors on a Eubank mechanism have a variable speed. The
doors will start slowly, accelerate to a fast speed, and then slow
down before coming to a stop.

Doors Obstructed

- The Status Light will flash in groups of 3

red followed by a pause. If  the doors meet an obstruction they
will sense the obstruction, stop momentarily, and move in  the
opposite direction for a few seconds. ---- Remove the
obstruction and then activate the doors. They should return to
normal run motion.

Doors Obstructed Both Ways

- The Status Light will flash in

groups of 4 red followed by  a  pause. Similar to Doors
Obstructed but doors are prevented from moving in either
direction. ----  Remove the obstruction and then activate the
doors. They should return to normal run motion.

Travel Too Far

- The Status Light will flash in groups of 5 red

followed by a pause. The  motor  is running but the doors are
not moving. ---- Has the motor box been uncoupled from the
track,  or is the motor box bent, causing it to become uncoupled
from the track?

Power Loss

- The Status Light will be on solid red. ---- There

has been a power loss (due  to  an electrical storm, etc.). When
next activated the doors will move at a slow speed to their full

closed position. If the doors are already closed they will not
move. The Status Light will return to  solid green and the doors
are ready for normal activation.

Optional Control Input Connections

Control Input- 8 position RJ 45 modular phone jack

Discrete control for use with 3rd party control.

Position 8- Open

Position 7- Stop

IR Receiver “Eye” input for Eubank, Inc. supplied external IR
reciever only.

Position 6 - V out

Position 5 - Vcc, 5v

Radio Power for external RF reciever only.

Position 4 - 24 VDC

Sequence control for use with 3rd party control.

Position 3 - Sequence- Open, Stop, Close, Stop

Position 2 - Common

Discrete control for use with 3rd party control.

Position 1 - Close

Control Input on Front of Motor Box

Figure 11

NOTE:

Making a momentary dry contact closure between the

common and the open, closed, stop, or sequence will
activate the system in that mode.

Status Indicator

Control Input

Figure 12

Control Input on Front of Motor Box

Summary of Contents for CM6SV65

Page 1: ...e protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio or television communications However there is no guarantee that the interference will not occur in a particular installation If this equipment does cause...

Page 2: ...ler s responsibility to make sure all components are properly assembled and installed using the instructions provided Read all instructions before using this furnishing DANGER TO REDUCE THE RISK OF ELECTRIC SHOCK ALWAYS unplug this furnishing from the electrical outlet before cleaning WARNING TO REDUCE THE RISK OF BURNS FIRE ELECTRIC SHOCK OR INJURY TO PERSONS Unplug from outlet before putting on ...

Page 3: ...e doors stop reverse run a few seconds and then stop again Auxiliary Controls There is an activator button located on the front of the motor box which will activate the doors Status Light The Status Light on the front of the Motor Box indicates the operating condition of the mechanism In normal operating conditions the status light will be solid green with the doors at rest and will blink a series...

Page 4: ...t to the top and with the notch tight against the back of the track NOTE The counterweight arms should extend 1 4 past the front of the tracks IMPORTANT Use screws of adequate length 4 Attach counterweight cables to the wheel plates 5 Remove thumbnut from stud on wheel plate 6 Slide cable eye over threaded stud on wheel plate 7 Secure cable to the plate with thumbnut 8 Screw the door plates to bac...

Page 5: ...Installation Instructions CM6SV65 and 83 5 Figure 2 ...

Page 6: ...of 12 wide x 3 4 thick flakeboard to 1 1 2 shorter than the length identified in step 3 IMPORTANT The weight of the panel MUST equal the combined weight of the counterweights Attaching and Testing The Counterweights 1 Secure mounting plate to counterweight with screws of adequate length 2 Remove thumbnut from stud on counterweight mounting plate 3 Slide cable eye over stud on the counterweight pla...

Page 7: ... just enough to give line of sight Two an IR sensor extension cord can be used to position the IR sensor in the cabinet near to the other remote controlled units For example near to the VCR or DVD player Install Light Dimmer Module Optional With the dimmer option installed cabinet lighting can be switched on or off or dimmed using the left buttons on the systems remote control To install the optio...

Page 8: ...ocations etc The system will then stop and remember these learned measurements Figure 8 System Controls and Indicators Learn Mode The CM6SV system has no limit switches The system uses an encoder on the motor to collect data and send it to the micro processor s memory The software learns about its environment speed time duration stop points etc during the initial setup of the unit and retains that...

Page 9: ...ar The Status Light will flash in groups of 5 red followed by a pause The motor is running but the doors are not moving Has the motor box been uncoupled from the track or is the motor box bent causing it to become uncoupled from the track Power Loss The Status Light will be on solid red There has been a power loss due to an electrical storm etc When next activated the doors will move at a slow spe...

Page 10: ...18 952 894 6918 Europe A Fellenoord 130 5611 ZB EINDHOVEN The Netherlands P 31 0 40 2668620 F 31 0 40 2668615 Asia Pacific A Room 30I Block D Lily YinDu International Building LuoGang BuJi Town Shenzhen CHINA Post Code 518112 P 86 755 8996 9226 8996 9236 8996 9220 F 86 755 8996 9217 8820 000019 2007 Chief Manufacturing www chiefmfg com 03 07 ...

Reviews: