30
MI300T 220V
q j
12
CAPA voltage
UPMCAPA = 0 V
PASS
No blocking
13
Voltage PM IGBT 1 and 2
UPMIGBT12 = xxx V
PASS or FAIL
Blocking
Problem controlling the power electronics, contact your
dealer.
14
Voltage PM IGBT 3 and 4
UPMIGBT34 = xxx V
PASS or FAIL
Blocking
15
IGBT test result 1
IGBT1 = xxx V
PASS or FAIL
Blocking
16
IGBT test result 2
IGBT2 = xxx V
PASS or FAIL
Blocking
17
IGBT test result 3
IGBT3 = xxx V
PASS or FAIL
Blocking
18
IGBT test result 4
IGBT4 = xxx V
PASS or FAIL
Blocking
Page CHECK n°2
1
Name of the product
CONNEXION TRANSFO
PASS or FAIL
Blocking
Check the connection of the power cable from the gripper to
the generator.
2
Test result primary detec-
tion transfo
DATE/TIME
PASS or FAIL
No blocking
3
Date and time
SHOW-ROOM
ON or OFF
No blocking
4
SHOW-ROOM mode
GGUN WELD SW =
x.xx V
PASS
No blocking
5
Welding trigger, gun
trigger and gun tempera-
ture test
GGUN OPEN SW = x.xx V
PASS or FAIL
Blocking
Check the connection of the power diode temperature sensor.
6
Trigger test on diode ope-
ning and temperature
TRANSFO TEMP = x.xx V
ON or OFF
Blocking
Overheating of the power transformer. Allow the machine to
cool down before starting up again.
7
Transformer primary
temperature
THICKNESS SENSOR =
xx.x mm
PASS
No blocking
8
Position sensor
WELDING VOLTAGE =
x.xx V
PASS
No blocking
9
Welding voltage
BACKUP CELL = x.xx V
PASS or FAIL
No blocking
10
Backup battery voltage
AIR PRESSURE = xx.x
bar si PASS
PASS or FAIL
Blocking
Air pressure sensor from the HS network, contact your dealer.
Network pressure
11
Clamp pressure
GUN PRESSURE = xx.x
bar si PASS
PASS or FAIL
Blocking
Air pressure sensor of the HS gripper, contact your dealer.
Gun presence detection
12
Détection présence pistolet
CONNEXION GUN
ON or OFF
No blocking
SPOT COUNT
A spot count tool keeps count of the different spot weld done using the same cap. If there is no
problem during the welding, the following message is displayed.
The count is displayed at the top left corner of the screen. Press the button
for 2 seconds to
reset the count after changing the caps.
The machine counts the number of points achieved with each arm independently. A warning
message appears on the screen when the limit of the points made by the headings is reached. The
message remains displayed after each point until the counter is reset.
If the caps are not changed after the warning message is displayed and the count is simply reset, they can deteriorate and have a negative
impact on the quality of the weld.
RECORDING FEATURES
The Identification mode is optional and can be activated using the «settings» menu.
If the identification mode is switched off, il suffit de saisir un nom de rapport et de l’activer pour mémoriser les points de soudure effectués.
The log allows to store the parameters of the spots made using the clamp. It is available in all the modes by pressing the 2 buttons
and
.
The user program is available in all modes by pressing the
and
buttons.
EN