26
MI300T 220V
q j
MANUAL mode
This mode is used to select the parameters of the spots by following the instructions of a repair book.
The parameters to set in this mode are:
- Current
- Duration
- Pressure
- Reference of the arm used.
Push the button
for 2 seconds to return to the AUTO mode.
MULTI mode
This mode is used to set precisely the thickness and type of steel for each sheet/panel .
The first element (thickness of sheet 1) is selected. The keys up and down are used to select the setting that
needs to be adjusted, where the keys right and left are used to increase or decrease the value. Highlight the
setting that needs to be adjusted.
The settings that need to be set when using this mode are:
- Thickness of the sheets/panels,
with a range between 0.60 mm and 2.50 mm.
- Type of steel
(coated steel, HLE/THLE steel, UHLE steel, bore steel (BORON)).
When welding a mix of different types of steel, select the strongest one.
- To activate the sheet/panel 3, press the scroll keys ( or ) to highlight sheet/panel 3. Then use they
keys + and - to select the thickness of the sheets/panels.
- Reference of the arm used.
Push the button
for 2 seconds to return to the AUTO mode.
MANUFACTURER
mode
The MANUFACTURER mode is optional; it can be modified using the « Settings» menu.
This mode is used to name a pre-registered spot based on the repair book issued by the manufacturer.
Spot welds programmed by the user can be recalled by selecting USER in the manufacturers list. Welding spots can be programmed using the GYSPOT
software and the welding spots settings module.
Push the button
for 2 seconds to return to the AUTO mode.
ENERGY mode
The ENERGY mode is optional and can be set using the «Settings» menu.
This mode is used to control the energy transmitted during the weld. This mode is not designed to be used
during repairs but for the benefit of manufacturers and quality control organisations conducting tests.
To enable this mode, first perform a weld without a load. Push the button (FIG 2 -11). The message «Do a spot without a load» is displayed on the
screen. Push the button again to calibrate. Once the calibration has been done, the machine displays the last values used in this mode for current
and energy. The use can then modify the welding current, energy and resistance. The duration of the weld will vary based on the time required for
the machine to reach the energy level required. If it is taking too long, the machine will display the error message «maximum duration reached».
Push the button
for 2 seconds to return to the AUTO mode.
EN