To reduce risk of injury, everyone using, installing, 
repairing, maintaining, changing accessories on, or 
working near this tool must read and understand 
these instructions before performing any such task.

The goal of Chicago Pneumatic is to produce tools that help you work safely and 
efficiently. The most important safety device for this or any tool is YOU. Your 
care and good judgment are the best protection against injury. All possible 
hazards cannot be covered here, but we have tried to highlight some of the 
important ones.

We, Chicago Pneumatic Tool Company, 1800 Overview Drive, Rock Hill, SC 29730 USA, 
declare under our sole responsibility that the product to which this declaration relates, is in 
conformity with the requirements of the Council Directive of June 1998 on the approximation 
of the laws of the Member States relating to machinery (98/37/EC).

Machine Name

 CP6110 Series Impact Wrenches

Machine Type

 Assembly Power Tool for Threaded Fasteners - No other use is 

permitted.

Serial No.

 Tools with No. 98000B or higher

Technical Data

1"Sq. Dr. 
Bolt size 1" Grade 5
Air pressure 90 psi (6.2 bar)
Torque range 1250-1900 ft.-lb. (1695-2576 Nm)

Harmonized Standards Applied

EN292

National Standards Applied

 ISO 8662-7, Pneurop PN8NTC1.2

Name And Position Of Issuer

 W.A. LeNeveu, President, Chicago Pneumatic Tool 

Company

Signature Of Issuer
Place And Date Of Issue

Rock Hill, SC 29730 USA, January 1998

Air Supply Requirements

1. Supply tool with 90 psig (6.2 bar) of clean, dry air. Higher pressure drastically 

reduces tool life.

2. Connect tool to air line using pipe, hose, and fitting sizes shown in the diagram on 

page 12.

Lubrication

1. Use an air line lubricator with SAE #10 oil, adjusted to two (2) drops per minute. If 

an air line lubricator cannot be used, add air motor oil to the inlet once a day.

2. Check clutch oil once each month. Use 2.0 oz. (59 ml) of SAE #30 oil or 

equivalent.

Operation

The intended use of this impact wrench is with impact rated sockets operating 
upon threaded fasteners. To operate, pull trigger on handle. To operate in forward 
rotation, rotate reverse valve located next to the trigger to position F. To operate 
in reverse, rotate to position R.

Noise & Vibration Declaration*

2

Vibration value 10.1 m/s , re. ISO 8662-7.

Maintenance

1. Disassemble and inspect air motor and impacting clutch every three (3) months if 

the tool is used every day. Replace damaged or worn parts.

2. High wear parts are underlined in the parts list. 
3. To keep downtime to a minimum, the following service kit is recommended: 

C155947 Tune-Up Kit

*These declared values were obtained by laboratory type testing in compliance with the stated standards and are not 

adequate for use in risk assessments. Values measured in individual work places may be higher than the declared 
values. The actual exposure values and risk of harm experienced by an individual user are unique and depend upon the 
way the user works, the workpiece and the workstation design, as well as upon the exposure time and the physical 
condition of the user. We, Chicago Pneumatic, cannot be held liable for the consequences of using the declared values, 
instead of values reflecting the actual exposure, in an individual risk assessment in a work place situation over which we 
have no control.

Sound pressure level 100 dB(A) in accordance with Pneurop PN8NTC1.2.  For 
sound power, add 10 dB(A).

Model "B" 

C155529  Rev. D

CP6110 Series 

Impact Wrench

Projectile Hazards

Always wear impact-resistant eye and face protection when involved with or 
near the operation, repair or maintenance of the tool or changing 
accessories on the tool. 
Be sure all others in the area are wearing impact-resistant eye and face 
protection.
Even small projectiles can injure eyes and cause blindness.
Do not use hand sockets. Use only impact wrench sockets in good condition.
Sockets in poor condition or hand sockets used with impact wrenches can 
shatter.
Always use the simplest hook-up possible. Long, springy extension bars and 
adapters absorb impact power and could break. Use deep sockets wherever 
possible.
Never operate the tool off of the work. It may run too fast and cause the 
accessory to be thrown off the tool.

Workplace Hazards

Slip/Trip/Fall is a major cause of serious injury or death. Beware of excess 
hose left on the walking or work surface.
High sound levels can cause permanent hearing loss. Use hearing 
protection as recommended by your employer or OSHA regulation (see 29 
CFR part 1910).
Maintain a balanced body position and secure footing.
Be in control of the throttle at all times. Do not get caught between the tool 
and the work.
Repetitive work motions, awkward positions and exposure to vibration can 
be harmful to hands and arms. If numbness, tingling, pain or whitening of the 
skin occurs, stop using the tool and consult a physician.
Avoid inhaling dust or handling debris from work process that can be harmful 
to your health.  Proper breathing protection must be worn when working with 
materials which produce airborne particles.
Proceed with care in unfamiliar surroundings. Be aware of potential hazards 
created by your work activity. This tool is not insulated for coming into 
contact with electric power sources.

Additional Safety Topics

This tool and its accessories must not be modified.
This tool is not recommended for use in explosive atmospheres.
Operators and maintenance personnel must be physically able to handle the 
bulk, weight and power of the tool.
For tools using the pin and O-ring socket retention system, use the O-ring to 
securely retain the socket pin.

For Additional Safety Information Consult:

Your employer union and/or trade association.
US Department of Labor (OSHA); Council of the European Communities 
and/or local codes.
“Safety Code For Portable Air Tools” (B186.1) available from: American 
National Standards Institute, Inc., 11 W. 42nd Street, New York, NY  10036, 
USA.
“Safety Requirement For Hand-Held Non-Electric Power Tools” available 
from: European Committee for Standardization, Rue de Stassart 36, 1050 
Brussels, Belgium.

Air Supply And Connection Hazards

Air under pressure can cause severe injury.
Always shut off air supply, drain hose of air pressure and disconnect tool 
from air supply when not in use, before changing accessories or when 
making repairs.
Never direct air at yourself or anyone else.
Whipping hoses can cause serious injury. Always check for damaged or 
loose hoses and fittings.
Do not use quick disconnect couplings at tool. See instructions for correct 
set-up.
Whenever universal twist couplings are used, lock pins must be installed.
Do not exceed maximum air pressure of 90 psi (6.2 bar) or as stated on tool 
nameplate.

Entanglement Hazards

Keep away from rotating drive.
Do not wear jewelry or loose clothing.
Choking can occur if neckwear is not kept away from tool and accessories.
Scalping can occur if hair is not kept away from tool and accessories.
Avoid direct contact with accessories during and after use. Gloves will 
reduce the risk of cuts or burns.
Use only proper accessory retainers (see parts list). Use deep sockets 
wherever possible.

Limited Warranty:   The "Products" of the Chicago Pneumatic  Tool Company ("CP") are warranted to  be 
free from defects in material and workmanship  for one year from the date of  purchase.  This Warranty
applies only to Products purchased new from  CP or its authorized dealers.   Of course, this Warranty 
does not apply to products which have  been abused, misused, modified, or repaired by  someone other 
than CP or its Authorized Service  Representatives.  If  a CP Product proves defective in  material or 
workmanship within one year after purchase,  return it to any CP Factory  Service Center or Authorized 
Service Center for CP tools, transportation  prepaid, enclosing your name and address, adequate  proof 
of date of purchase, and a short  description of the defect.   CP will, at its option, repair or  replace defective 
Products free of charge.   Repairs or replacements are warranted as described  above for the remainder 
of the original warranty period.   CP's sole liability and your exclusive  remedy under this Warranty is 
limited to repair or replacement of the  defective Product.

(There Are No Other Warranties Expressed

Or Implied And CP Shall Not Be Liable For Incidental, Consequential, Or Special Damages, Or
Any Other Damages, Costs Or Expenses Excepting Only The Cost Or Expense Of Repair Or
Replacement As Described Above.)

Summary of Contents for CP6110 Series

Page 1: ...f the work It may run too fast and cause the accessory to be thrown off the tool Workplace Hazards Slip Trip Fall is a major cause of serious injury or death Beware of excess hose left on the walking or work surface High sound levels can cause permanent hearing loss Use hearing protection as recommended by your employer or OSHA regulation see 29 CFR part 1910 Maintain a balanced body position and ...

Page 2: ...ado de herramientas CP con el transporte pagado e incluya su nombre y dirección una prueba adecuada de la fecha de compra y una breve descripción del defecto CP reparará o sustituirá según su criterio los Productos defectuosos sin cargos Las reparaciones o sustituciones tal como se describen arriba se garantizan por el tiempo que resta de la garantía original La única responsabilidad de CP y su co...

Page 3: ... ou remplacera gratuitement à sa discrétion les produits défectueux Les réparations ou produits de remplacement seront garantis comme décrit ci dessus pour le reste de la durée de la garantie d origine La seule responsabilité de CP et vos seules prétentions dans le cadre de la présente Garantie se limitent à la réparation ou au remplacement du produit défectueux Il n existe aucune autre garantie i...

Page 4: ... nome e indirizzo allegando un adeguato documento indicante la data d acquisto e una breve descrizione del difetto rilevato CP effettuerà a propria discrezione la riparazione o la sostituzione gratuita dei prodotti difettosi Eventuali riparazioni o sostituzioni sono garantite per il resto del periodo di garanzia originario La responsabilità esclusiva di CP e la garanzia sono limitate alla riparazi...

Page 5: ...igt ovan för den återstående tiden av den ursprungliga garantin CP s ansvarsskyldighet och ersättning enligt denna garanti begränsas till reparation eller ersättning av den felaktiga produkten Inga andra garantier uttryckliga eller underförstådda gäller och CP är inte heller ansvarsskyldig för obetydliga fel följdskador eller särskilda skador eller andra skador kostnaderellerutgifter utomkostnadfö...

Page 6: ...inaus werden keinerlei ausdrücklichen oder stillschweigenden Garantien gewährt CP übernimmt über die oben beschriebenen Instandsetzungs oder Ersatzleistungen hinaus keine Haftungfürmittelbare unmittelbareodersonstigeFolgeschäden oder kosten BEACHTEN Sie zusätzlich folgende Sicherheitshinweise Sicherheitsbestimmungen des Arbeitgebers der Arbeitnehmervertretung und der Berufsgenossenschaften Bestimm...

Page 7: ...ito A CP em sua discrição irá reparar ou substituir os Produtos defeituosos sem custo Osreparosouassubstituiçõessãogarantidas comodescritoacimaparaorestantedo períododegarantia original A única responsabilidade CP e seu único remédio sob esta Garantia está limitada ao reparo ou reposição do Produto defeituoso Não existem outras garantias expressas ou implícitas e a CP não será responsável por dano...

Page 8: ... eller bytte det defekte produktet uten omkostninger for kunden CPs eneste forpliktelse og kundens eneste krav i henhold til denne garantien er at det defekte produktet blir reparert eller byttet Ingen andre uttrykte eller underforståtte garantier gis ogCPfraskriversegethvertansvarfor tilfeldigeskader følgeskader skadersomskyldesspesielle omstendigheter eller andre typer ødeleggelser kostnader og ...

Page 9: ...ankoopdatum en een korte beschrijving van het mankement CP zal naareigengoeddunken defecteproductengratisrepareren ofvervangen Reparatiesofvervangingenzijn slechts gegarandeerd zoals hierboven beschreven voor de rest van de oorspronkelijke garantieperiode De enige aansprakelijkheid van CP en uw enige verhaal op grond van deze garantie zijn beperkt tot reparatie of vervanging van het defecte produc...

Page 10: ...P fragten forudbetalt sammen med navn og adresse fyldestgørende bevis på købsdatoen og en kort beskrivelse af defekten CP vil efter eget valg reparere eller udskifte defekte produkter uden beregning Reparerede eller udskiftede produkter er kun garanteret som beskrevet ovenfor og kun for resten af den oprindelige garantiperiode CPs eneste ansvar og dit eneste retsmiddel under denne garanti er begræ...

Page 11: ...oko korjaa tai vaihtaa vialliset tuotteet veloituksetta oman harkintansa mukaan Korjauksista tai vaihdossa toimitetuista tuotteista annetaan takuu ainoastaan alkuperäisestä takuusta jäljellä olevaksi ajaksi CP n ainoa vastuu ja ostajan ainoa korvausvaatimus tämän takuun aikana on rajoitettu tässä mainittuun viallisen tuotteen korjaukseen tai vaihtamiseen Mitään muita ilmaistuja tai oletettuja taku...

Page 12: ...ult 199 route de Clisson F 44230 Saint Sébastien sur Loire France Fax 33 0240802000 Telephone 33 0240802000 INDIA Industrial Construction FRANCE Industrial Construction see United States MEXICO Industrial Construction Alliance Tools S A PTY Ltd Saiigna Street Hughes Business Park Witfield X30 Boksburg South Africa Telephone 27 118219300 UNITED STATES Industrial Construction Power Tools Australia L...

Page 13: ...HANDLE MOTOR HOUSING CLUTCH SHANK Finding information using your Catalog Code Letter Example CP 6110 PASED 85 155 103 157 1 42 158 23 56 25 24 3 2 5 7 4 6 26 28 8 46 45 16 18 9 14 MODEL A HANDLE Discontinued 16 17 83 136 23 26 25 24 28 27 106 65 94 58 95 67 69 41 70 14 42 84 66 68 111 107 15 13 29 16 46 62 45 4 1 2 3 7 5 9 10 109 59 110 61 108 8 60 105 90 151 150 114 115 105C 107 106 105B 102 98 1...

Page 14: ... P089109 CA144007 C134724 C134691 Bushing Air Inlet Screen Air Spring Seat Valve Ball 562 in dia Ring Retaining Spacer Valve Pin Push Outside Trigger Pin Push Inside Trigger Link Trigger Trigger Inside Pin Roll 156 x 1 in 1 3 4 2 2 1 8 2 1 4 2 1 2 2 5 8 Bushing Air Inlet Screen Air Spring Retainer O Rong Valve Throttle O Ring 012 Pin Push Bushing Throttle Valve Bushing Incl Index No 42 Trigger Out...

Reviews: