64
The appliance is equipped with a sensor to monitor the function of the flue (TTB Switch) If the
evacuation of the combustion products is interrupted (caused by lack of flue pull or blockage),
the TTB will operate and shut the appliance off. If for any reason the fire does shut off, allow at
least 5 minutes to elapse before attempting to relight as described in the
“lighting instructions”
section, on pages 65-69. If the appliance repeatedly shuts off after being re-started (as detailed
in the
‘Lighting instructions’ section), a GAS SAFE registered engineer should be contacted to
examine the appliance and installation.
Ventilation
– GB appliances over 7kW (net) requires permanent ventilation and should be
fitted in accordance with BS 5440-2 and must be checked on a regular basis to ensure there is
no obstruction.
The appliance when lit from cold will start off with a blue flame and will gradually turn more
yellow as the flue, and appliance heat up.
Important Notes
The appliance must only to be opened for maintenance.
The appliance must not be operated if the appliance glass is open, broken or has been
removed.
The appliance should always be observed when lighting.
Improper installation, service, maintenance, adjustment or
alterations may cause injury or property damage
Do not disturb or place anything on the fire base as this will affect combustion.
Do not operate the appliance if any part of the appliance is damaged
The appliance must be installed and maintained by a suitably qualified heating
engineer.
Ensure this manual remains with the appliance.