Page 6
3 Installation and Interconnections
3.1 Wiring – Power & comms
Type : M12 X coded (recommended cable of type 'Harting 09478411002 or
equivalent)
Pin
802.3at Mode A
(2 pairs)
802.3at Mode B
(4 pairs)
Passive PoE
(DC Supply)
(4 pairs)
1
TX+ & DC+
TX+
TX+
2
TX- & DC+
TX-
TX-
3
RX+ & DC-
RX+
RX+
4
RX- & DC-
RX-
RX-
5
DC-
V
Short
Together
6
DC-
V
7
DC+
Supply -V
Short
Together
8
DC+
Supply -V
3.1.1 Changing the power mode of the device
1.
Remove all fourteen screws from the baseplate using a 2.0mm hex driver.
2.
Carefully remove the baseplate from the device to avoid damaging the gasket.
3.
Adjust DIP switch to required settings. See table below.
4.
Change the metal identifying tag on the side of the case to show the correct mode
(DC or PoE).
5.
Re-insert the gasket in the correct position and screw down baseplate using the
same hardware.
3.1.2 Internal DIP Switch Settings for flightDAQ-TL
SW1 SW2 SW3 Mode
OFF OFF OFF Normal operation - PoE Mode
(Default)
ON
ON
ON
Normal operation - DC Mode
ON
OFF -
Hard reset function
OFF ON
-
Factory default function
Summary of Contents for FlightDaq-TL
Page 20: ...Page 19 5 2 The Setup tab Figure 5 21 Main Setup page...
Page 25: ...Page 24 Figure 5 52 Live Data Page Figure 5 53 Live Data Page...
Page 46: ...Page 45 Select an additional Scan List in this case we have chosen 4...
Page 47: ...Page 46 Then disable the secondary and tertiary data streams...