36
INFORMATION CONCERNING REPLACEMENTS
8
Replacing the pinions of the dispensing unit
For this operation, proceed as outlined below.
1) Unscrew the nut (
A
), loosen the screw (
E
) and remove
the casing (
B
).
2) Move the tensioner (
C
) and remove the chain (
D
).
CAUTION
The tensioner could move unexpectedly, causing in-
jury to the hands.
Proceed with the utmost caution.
3) Fit the chain on the pinions and the tensioner.
NOTICE
Fit the chain with the joining link positioned as
sho
wn in the figure.
4) Fit the casing (
B
), tighten the nut (
A
) and the screw
(
E
).
Replacing the dispensing unit chain