Setup
-6-
COLORado™ Zoom Tour WW User Manual Rev. 05
3. Setup
AC Power
The COLORado™ Zoom Tour WW has an auto-ranging power supply that works with an
input voltage range of 100~240 VAC, 50/60 Hz.
Make sure that you are connecting this product to the proper voltage. To determine the
power requirements for the COLORado™ Zoom Tour WW, refer to the specification label
affixed to the product or the specifications in this manual.
Refer to the
Technical Specifications
chart.
Always connect this product to a protected circuit with an appropriate electrical
ground to avoid the risks of electrocution or fire.
The listed current rating indicates the maximum current draw during normal operation. For
more information, download the document
Sizing Circuit Breakers
from the CHAUVET®
website:
www.chauvetpro.com
.
Never connect this product to a rheostat (variable resistor) or dimmer circuit, even if
the rheostat or dimmer channel serves only as a 0% to 100% switch.
AC Plug
The COLORado™ Zoom Tour WW comes with a power input cord terminated with a
Neutrik® powerCON® A connector on one end and an Edison plug on the other end (US
market). If the power input cord that came with your product has no plug or you need to
change the Edison plug, use the table below to wire the new plug.
Connection
Wire (US)
Wire (Europe)
Screw Color
AC Live
Black
Brown
Yellow or Brass
AC Neutral
White
Blue
Silver
AC Ground
Green/Yellow
Green/Yellow
Green
Power Linking
The COLORado™ Zoom Tour WW supports power linking. You can power link up to nine
(9) products at 120 VAC.
This product comes with a power input cord. This product does not come with a power
linking cable; however, a power linking cable is available as an option.