Section 360-880-202

2

1.

GENERAL

1.1

Document Purpose

This document provides general, installation and testing information for the Secondary T1 Unit (ST1U), shown in

Figure 1. This document covers model number 3608-80.

1.2

Document Status

This document is reprinted to add additional features (”Dual” and “Protection” T1 modes).

1.3

Equipment Function

The ST1U is part of the 360-80 Intelligent Channel Bank (ICB). It combines the functions of a line interface unit

(LIU) and a channel service unit (CSU), allowing direct connections to public T1 networks. The ST1U is a secon-

dary T1 unit for the ICB, providing normal/drop and re-insert (D&RI), dual T1 mode and protection mode when

used with the T1 controller with SNMP (T1-S).

1.4

Equipment Location/Mounting

Mount the ST1U in the secondary (half-size) slot of the 360-80. One T1-S controller unit (issue 2 or later) must be

installed in the primary slot for proper system operation.

Note:

This unit must be mounted in an issue 3 or later 360-80 shelf.

1.5

Equipment Features

This unit provides the following features:

Downstream data blocking or broadcast for dropped timeslots (normal/D&RI mode only).

Independent T1 loop timing (dual T1 mode only).

Transport Protection switching (protection mode only).

Drop and re-insert operation with bypass (normal/D&RI mode only).

Front panel status LEDs.

Front panel T1 monitor jacks.

Time slot assignment on a per-channel basis.

Auto framing and identification (SF or ESF).

Auto line coding and identification (AMI or B8ZS).

Hot unit insertion or extraction.

24-channel T1 multiplexing operation (up to 48 channels in dual T1 or D &RI modes).

Temperature hardened (

40 to +65 C).

Combines the functions of a LIU and a CSU, allowing direct connections to public T1 networks.

Operates in either superframe (SF) or extended superframe (ESF) mode, uses AMI or B8ZS line

coding, & performs all loopback, test & performance monitoring of the T1 interface (local & remote).

UL/CSA listed and FCC verified.

Meets Bellcore 1089, 43801, 62411, 54016, TR-57 and ANSI T1.403 standards for T1.

1.6

Performance History

This unit stores performance history for the last 30 days in 24-hour intervals and over the last 24 hours in 15-min-

ute intervals. This performance history includes failed seconds, errored seconds and severely errored seconds

(per T1M1.3/93-00). The current 15-minute interval can be reset or the current 24-hour interval can be reset.

When the current 24-hour interval is reset all 15-minute intervals within those 24 hours are reset.

Summary of Contents for 3608-80 Secondary T1

Page 1: ...subject to change without notice Page 1 of 18 3608 80 Secondary T1 Unit CONTENTS PAGE Part 1 GENERAL 2 Part 2 INSPECTION 3 Part 3 APPLICATION GUIDELINES 4 Part 4 CIRCUIT DESCRIPTION 7 Part 5 INSTALLA...

Page 2: ...ependent T1 loop timing dual T1 mode only Transport Protection switching protection mode only Drop and re insert operation with bypass normal D RI mode only Front panel status LEDs Front panel T1 moni...

Page 3: ...tion Red AR Alarm Status LED Yellow AY Alarm Status LED Loss of frame LOF Alarm Status Loss of signal LOS Alarm Status Power status LED T1 framing selected Line code Trunk processing TP status LED Lin...

Page 4: ...and the T1 of the ST1U to be connected to two different 360 80 ICBs These two T1s run independently of each other and allow the 360 80 system to provide up to 1 5 Mbps to each T1 for a total of over...

Page 5: ...switch to the protection mode See Figure 4 for a typical configuration Note Both T1 S units should be set for the same error threshold 360 80 Primary T1 360 80 T1 Protection T1 S ST1U T1 S ST1U Figure...

Page 6: ...Re Insert 8 channels west and 8 channels east Drop Re Insert 16 channels Terminate 360 80 ICB 360 80 ICB 360 80 ICB A B C West East Site 1 Site 2 8 channels west Figure 6 Drop and Re Insert Applicati...

Page 7: ...lay path for the T1 facility as part of the assembly as shown in Figure 8 When de energized these relays bypass the ICB and connect the WEST primary T1 to the EAST secondary T1 When the ST1U and T1 S...

Page 8: ...des monitor jacks to monitor this T1 The T1 then goes to the EAST TIMING and FRAMING block where the circuit detects either SF or ESF framing A loss of framing signal will cause the AR LED to light an...

Page 9: ...stalled card will be allocated to phantom channels These timeslots must be de allocated before they can be allocated to a channel When a different card is inserted into a chassis slot that had timeslo...

Page 10: ...serted between the channel and the same timeslot of the other T1 Primary Secondary W D I E Time Slot Mode has No Effect on Data in Both Directions Figure 10 Drop at T1 Primary and Secondary for the Sa...

Page 11: ...ass Through because when both primary and secondary timeslot modes are set to broadcast the data passes through the 360 80 Primary Secondary W D I E Controlled by Secondary TS Mode Controlled by Prima...

Page 12: ...no other action is taken Red or yellow alarms detected on the East facility will illuminate the respective AR and or AY LEDs When the red alarm condition no longer exists for approximately 15 seconds...

Page 13: ...tem 6 After the self test is performed check the software provisioning of the unit using either the front panel craft interface on the front of the controller unit or the network management interface...

Page 14: ...ible indications of present alarm conditions it does NOT clear the alarm If a new alarm occurs the audible indication will re enable Table 1 LED Definitions Label Color Indicates that POWER Green The...

Page 15: ...ction Line Near End Line Far End Payload Far End None Remote Control Method None Occupy One Channel Facility Data Link ESF Format Only Facility Data Link Bypass Drop and Re insert Only Auto Bypass For...

Page 16: ...arton in which the replacement was shipped using the pre addressed shipping label provided Call your customer service representative at the telephone number above for more details 9 4 Standard Repair...

Page 17: ...to monitor the secondary T1 signal both transmit and receive without interference Alarm interface and contacts The system provides visual and audible alarm contact clo sure when the channel bank is i...

Page 18: ...3 Physical Specifications Feature U S Metric Height 0 75 inch 1 9 centimeters Width 5 64 inches 14 32 centimeters Depth 9 25 inches 23 49 centimeters Weight 0 64 pound 290 grams Temperature 40 to 149...

Reviews: