5.4.2. T1 Jacks

The RJ48 connectors on the rear of the ST1U are for the T1-S, east/secondary T1 and west/primary T1.

Table 2.  RJ-48C T1 Jack Pinouts

Pin #

Use

1

R (RCV from network)

1 2 3 4 5 6 7 8

2

T (RCV from network)

1 2 3 4 5 6 7 8

3

4

R1 (XMIT to network)

5

T1 (XMIT to network)

6

7

8

6.

OPTIONING

This unit comes from the factory with default provisioning, which can be changed through the Network Manage-

ment software (NMS) or the craft terminal interface. See the NMS or craft terminal interface documentation for

procedures. The provisioning options are as follows with the default optioning noted:

Option

Choices

Default

T1 Frame format

Superframe (SF), Extended Superframe (ESF)

ESF

Line Build Out (LBO)

110, 220, 330, 440, 550, 660 ft.  OR  0, 7.5, 15, 22dB 0-110  ft.

T1 Line Code

AMI, B8ZS

B8ZS

T1 Loopback Selection

Line Near End, Line Far End, Payload Far End

None

Remote Control Method

None, Occupy One Channel, Facility Data Link (ESF

Format Only)

Facility Data Link

Bypass (Drop and Re-insert

Only)

Auto Bypass, Forced No Bypass

Auto Bypass

7.

ALARMS

This unit provides for alarm contacts for audible and visual alarms. Access to the alarm contacts is provided on

the 360-80 shelf. Pressing the audible alarm cut-off (ACO) switch on the ST1U clears the secondary alarm indica-

tion for the audible alarm contacts, stopping the audible notice of the alarm (the alarm itself is NOT cleared by

pressing the ACO switch). See the shelf documentation for information on wiring. The unit generates alarm indi-

cations based on the configuration of the PRI T1 alarm registers (Normal, CM2, CM3). See section on network

management for more information.

8.

TECHNICAL ASSISTANCE

If technical assistance is required, contact Charles Industries’ Technical Services Center at:

847-806-8500
847-806-8556 (FAX)
800-607-8500
[email protected] (e-mail)

Summary of Contents for 3608-80 Secondary T1

Page 1: ...subject to change without notice Page 1 of 18 3608 80 Secondary T1 Unit CONTENTS PAGE Part 1 GENERAL 2 Part 2 INSPECTION 3 Part 3 APPLICATION GUIDELINES 4 Part 4 CIRCUIT DESCRIPTION 7 Part 5 INSTALLA...

Page 2: ...ependent T1 loop timing dual T1 mode only Transport Protection switching protection mode only Drop and re insert operation with bypass normal D RI mode only Front panel status LEDs Front panel T1 moni...

Page 3: ...tion Red AR Alarm Status LED Yellow AY Alarm Status LED Loss of frame LOF Alarm Status Loss of signal LOS Alarm Status Power status LED T1 framing selected Line code Trunk processing TP status LED Lin...

Page 4: ...and the T1 of the ST1U to be connected to two different 360 80 ICBs These two T1s run independently of each other and allow the 360 80 system to provide up to 1 5 Mbps to each T1 for a total of over...

Page 5: ...switch to the protection mode See Figure 4 for a typical configuration Note Both T1 S units should be set for the same error threshold 360 80 Primary T1 360 80 T1 Protection T1 S ST1U T1 S ST1U Figure...

Page 6: ...Re Insert 8 channels west and 8 channels east Drop Re Insert 16 channels Terminate 360 80 ICB 360 80 ICB 360 80 ICB A B C West East Site 1 Site 2 8 channels west Figure 6 Drop and Re Insert Applicati...

Page 7: ...lay path for the T1 facility as part of the assembly as shown in Figure 8 When de energized these relays bypass the ICB and connect the WEST primary T1 to the EAST secondary T1 When the ST1U and T1 S...

Page 8: ...des monitor jacks to monitor this T1 The T1 then goes to the EAST TIMING and FRAMING block where the circuit detects either SF or ESF framing A loss of framing signal will cause the AR LED to light an...

Page 9: ...stalled card will be allocated to phantom channels These timeslots must be de allocated before they can be allocated to a channel When a different card is inserted into a chassis slot that had timeslo...

Page 10: ...serted between the channel and the same timeslot of the other T1 Primary Secondary W D I E Time Slot Mode has No Effect on Data in Both Directions Figure 10 Drop at T1 Primary and Secondary for the Sa...

Page 11: ...ass Through because when both primary and secondary timeslot modes are set to broadcast the data passes through the 360 80 Primary Secondary W D I E Controlled by Secondary TS Mode Controlled by Prima...

Page 12: ...no other action is taken Red or yellow alarms detected on the East facility will illuminate the respective AR and or AY LEDs When the red alarm condition no longer exists for approximately 15 seconds...

Page 13: ...tem 6 After the self test is performed check the software provisioning of the unit using either the front panel craft interface on the front of the controller unit or the network management interface...

Page 14: ...ible indications of present alarm conditions it does NOT clear the alarm If a new alarm occurs the audible indication will re enable Table 1 LED Definitions Label Color Indicates that POWER Green The...

Page 15: ...ction Line Near End Line Far End Payload Far End None Remote Control Method None Occupy One Channel Facility Data Link ESF Format Only Facility Data Link Bypass Drop and Re insert Only Auto Bypass For...

Page 16: ...arton in which the replacement was shipped using the pre addressed shipping label provided Call your customer service representative at the telephone number above for more details 9 4 Standard Repair...

Page 17: ...to monitor the secondary T1 signal both transmit and receive without interference Alarm interface and contacts The system provides visual and audible alarm contact clo sure when the channel bank is i...

Page 18: ...3 Physical Specifications Feature U S Metric Height 0 75 inch 1 9 centimeters Width 5 64 inches 14 32 centimeters Depth 9 25 inches 23 49 centimeters Weight 0 64 pound 290 grams Temperature 40 to 149...

Reviews: