15
CHARGER SETTINGS
Setting Parameters
During the initial installation, the setting parameters must be set by
the manufacturer, operating partner, or service partner. Changes
may only be made by trained personnel.
To access settings window:
1) Touch the ChargeTronix Logo
2) Provide the password. Password will be shared with the
authorized representative.
3)
Select ‘system settings’
PARAMETER
VALUE
TIME ZONE
UTC+HH:MM
PSM QUANTITY
1
POWER OUT MODE
1
OCCUPLIED PLUG
1
PSM MAX VOLTAGE
1000
PSM MAX CURRENT
300
PSM MID VOLTAGE
200
PSM MID CURRENT
80
PSM MIN VOLTAGE
150
PSM MIN CURRENT
1
PMAX
20000
CCS NETWORK 1
ETH1
INSYS PLC MAC 1
00:00:00:00
TIME
2020-08-20
T20:46:25
.
S.NO
PARAMETERS
VALUE
REMARKS
1
NETWORK
ETH
Ethernet - DO NOT CHANGE
2
NETCFGFILE
/etc/network/interfaces
Path - DO NOT CHANGE
3
WLAN CONF
/home/guest/wpa_supplicant.conf
Path - DO NOT CHANGE
4
DEVICE IP
192.168.2.5
IP Address of Device
5
DEVICE GATEWAY
192.168.2.1
IP Address of Gateway
6
DEVICE NET MASK
255.255.255.0
IP Address of Mask
7
SERVICE URL
ws://localhost:8080/ocpp/
OCPP Server URL
8
DEVICE ID
1020180520001001
Device ID (alphanumeric)
9
CHARGE POINT VENDOR
ChargeTronix
Charger OEM - DO NOT CHANGE
10
CHARGE POINT MODEL
DC
Charger Type - DO NOT CHANGE
11
ADPATH
./pic
Path - DO NOT CHANGE
12
QRCODE NAME
NA
13
LANG
en
Path - DO NOT CHANGE
14
MODE
offline/record/upload/debug
Path - DO NOT CHANGE
15
CHARGING PIC
/img/charging_tata.jpg
Path - DO NOT CHANGE
16
IDLE PIC
/img/standby.jpg
Path - DO NOT CHANGE
17
LCM
1cm=/dev/tty54
Path - DO NOT CHANGE
18
LCM ENCODE TYPE
UNICODE
Encode - DO NOT CHANGE
19
LCM PASSWORD
123456
Password for Access
20
RFID
RFID0=/dev/ttyS1
Path - DO NOT CHANGE
21
PLUG1
GBTDC1:2=/dev/ttyS0
Path - DO NOT CHANGE
22
PLUG2
GBTDC2:2=/dev/ttyS0
Path - DO NOT CHANGE
23
DC1QRCODE NAME
NA
24
RFID ORIGINAL NUMBER
0
NA