1. All models are GRAVITY DRAIN machines equipped with a 2" O.D. hose connection.
2. The maximum flow rate is 15 U.S. gpm/56.8 Lpm.
3. Drain height for all models must not exceed 8-7/8" [225mm] above the finished floor.
4. The drain connection is made to the dishwasher from underneath the machine. An access
hole is provided in the machine base.
NOTE:
DO NOT VENT THE DISHWASHER INTO WALLS, CEILINGS OR ENCLOSED PLACES.
All venting must comply with local codes.
Ventilation Connections
Installation
Drain Connections
Vent Fan Signal Connection
A two point terminal block is provided inside the top-mounted control cabinet to provide
a 120VAC, 1 AMP Max Load signal.
NOTE:
The Vent Fan Signal Connection supplies 120VAC to a control relay (supplied by others) when the
dishwasher is ON and O VAC when the dishwasher is OFF. Power to operate the vent fan
(supplied by others) must be supplied separately.
VENT FAN 120VAC
10