201004 - 7500W WIRELESS REMOTE START GENERATOR
OPERATION
24
NOTICE
Keep choke in “CHOKE” position for only 1 pull of the recoil
cord. After first pull, move choke to “RUN” position for up to
3 pulls of the recoil cord. Too much choke leads to spark plug
fouling/engine flooding due to lack of incoming air. This will
cause the engine not to start.
NOTICE
For gasoline restarts with hot engine in hot ambient
temperature > 86°F (30°C),
keep choke in 75% of the
“CHOKE” position for only 1 pull of the recoil cord. After first
pull, move choke to “RUN” position for up to 3 pulls of the
recoil cord. Too much choke leads to spark plug fouling/engine
flooding due to lack of incoming air. This will cause the engine
not to start.
NOTICE
For gasoline starting in cold ambient temperature < 59°F
(15°C),
the choke must be in 100% of “CHOKE” position
for manual start procedures. Do not over-choke. As soon as
engine starts, gradually move the choke lever to the “RUN”
position over a 2-5 second duration.
NOTICE
For Wireless and Electric Start only:
A safety feature is
provided which delays the electrical power availability during
starting mode. The delay lasts for approximately 15 seconds.
The delay is provided to prevent damage to the generator
if electrical loads are inadvertently turned on during engine
startup.
NOTICE
If the engine starts but does not continue to run make certain
that the generator is on a flat, level surface. This engine is
equipped with a low oil sensor that will prevent the engine
from running when the oil level falls below a critical threshold.
battery
NOTICE
When the battery switch is in the “ON” position, the switch
will light up if the battery is sending out a charge. If the switch
does not light up while in the “ON” position, check that the
battery connection is still good.
NOTICE
The supplied 12V battery does re-charge while the engine
is running and the battery switch is turned ON, but it is also
recommended that the battery be fully charged at least once
per month or maintained with a trickle charger or battery
maintainer (not included).
Connecting Electrical Loads
Let the engine stabilize and warm up for a few minutes after
starting.
Plug in and turn on the desired 120 or 240 (if applicable) Volt AC
single phase, 60 Hz electrical loads.
–
DO NOT connect 3-phase loads to the generator.
–
DO NOT overload the generator.
WARNING
Always remember to plug your appliances directly into the
generator and do not plug the generator power cord into any
electrical outlet or connect to the circuit breaker panel in your
home. Connecting a generator to your home’s electric utility
company’s power lines, or to another power source, called
‘backfeeding’ is a dangerous practice that is illegal in many
states and municipalities.
This action if done incorrectly could damage your generator,
appliances and could cause serious injury or death to you
or a utility worker when attempting to restore power during
an outage occurrence in the neighborhood who may then
unexpectedly encounter high voltage on the utility line and
suffer a fatal shock.
Whether injuries occur or not, if installed incorrectly and not to
applicable laws and codes, you may be subject to fines or the
utility company may disconnect your home power should this
practice be found in your home.
If the generator will be connected to a building electrical
system, those connections must isolate the generator power
from the utility power. You are responsible for ensuring your
generator’s electricity does not backfeed into the electric
utility power lines. These connections must comply with all
applicable laws and codes – Consult your local utility company
or a qualified electrician to properly install this connection.