Door Board Overview
The CAPXM has a combination of access control inputs/outputs on the Door Board that work in conjunction to control up to 2
access points.
See page 17 for wiring diagram.
INPUT/OUTPUT
USED FOR
Relay Output 1
Gated Operator, Door Strikes, Maglocks, Lights (for control-only power to be provided by external
power supply), Alarm Shunt
Relay Output 2
Wiegand Output 1
Standard 26-bit, 30-bit Wiegand, HID 37-bit with Facility Code, Transcore 37-bit, 32-bit MiFare
Wiegand Output 2
Supervised Input 1
Closed Door Sensor (Supervised EOL or unsupervised), Closed Limit Gate Sensor (Supervised EOL
or unsupervised), Open Limit Gate Sensor (Supervised EOL or unsupervised)
Supervised Input 2
NOTE:
Only the 26-bit Wiegand protocol is compatible in UL installations.
DOOR BOARD
Door 1
Door 2
PRIMARY
RELAY
AUXILIARY
RELAY
WIEGAND
OUTPUT
WIEGAND
INPUT
WIEGAND
INPUT
REQUEST
TO EXIT
PRIMARY
RELAY
AUXILIARY
RELAY
STATUS
REQUEST
TO EXIT
STATUS