Wiegand Output
DOOR BOARD
Third Party Access System
Wiegand Input
(This Device/Reader Must
be Listed to UL 294.)
Data-0
Ground
Data-1
Disconnect power BEFORE making electrical connections.
The CAPXM offers a Wiegand output capable of 26-bit transmission of the
following data:
• Success Call with access granted by the resident. The CAPXM will provide a myQ
®
Business™ specified facility code followed by the
Directory Code of the resident that granted access.
And/Or
• Successful access through Entry Code. The CAPXM will provide a myQ
®
Business™ specified facility code followed by the
successful Entry Code.
And/Or
• Successful access with a Wiegand credential. The CAPXM will pass along the successful credential Facility Code and ID.
PRE-INSTALL
NETWORK
INSTALL
ACCESS CONTROL
INTRODUCTION
INTRODUCTION
PRE-INSTALL
NETWORK
INSTALL
ACCESS CONTROL
INTRODUCTION
PRE-INSTALL
NETWORK
INSTALL
ACCESS CONTROL
INTRODUCTION
PRE-INSTALL
NETWORK
INSTALL
ACCESS CONTROL
INTRODUCTION
PRE-INSTALL
NETWORK
INSTALL
ACCESS CONTROL
Postal Lock
1. Remove the wing nut and plug. Discard the
wing nut and plug.
2. Remove 4 mounting nuts from studs.
3. Install postal lock using 4 nuts.
4. Cut the factory installed wire tie from the
postal lock switch.
5. The postal lock switch is wired from the
factory.