background image

16

1

Connect Internet

The CAPXM can connect to the Internet with a wired connection or with Wi-Fi

®

 (wireless). See page 10 for Internet 

requirements.

 

Make sure you are in the Admin Mode before you connect to the Internet. If you are not in Admin 

Mode, flip switch #1 to the ON position on the Control Board, press the Network tab on the CAPXM display, and 

press the “Change Network Settings” button. Follow the instructions according to your application. 

PRE-INSTALL

NETWORK

INSTALL

ACCESS CONTROL

INTRODUCTION

INTRODUCTION

PRE-INSTALL

NETWORK

INSTALL

ACCESS CONTROL

INTRODUCTION

PRE-INSTALL

NETWORK

INSTALL

ACCESS CONTROL

INTRODUCTION

PRE-INSTALL

NETWORK

INSTALL

ACCESS CONTROL

INTRODUCTION

PRE-INSTALL

NETWORK

INSTALL

ACCESS CONTROL

On the display, select each tab in Admin Mode to validate setup (network, 

inputs, outputs, etc.). Once you have validated the setup, exit Admin Mode.

Validate Setup

2

OPTION 1

 

Wired Connection

The Local Area Network (LAN) port is a 10/100 Ethernet interface with an RJ45 jack for connecting the CAPXM to a hub, switch, or router in 

order for it to gain connectivity to the Internet. Use a straight, (i.e., non-crossover) Cat5e, or Cat6 cable to connect to a local hub, switch or 

router. This type of cable is referred to as an Ethernet cable in this manual. 
1.   Connect an Ethernet cable from the hub, switch, or router to the 

LAN port on the Control Board. When connected properly, the 

green and amber LED on the Ethernet port of the control board will 

light/flicker (the control board is located on the back of the CAPXM 

display). If the green LED is not lit, check the connections on the 

CAPXM and the Ethernet hub. 

2.   On the display, select 

Wired Network

 if dynamic configuration 

(DHCP) is desired or select 

Manual Setup

 for a static IP address.

OPTION 2

 

Connect through Wi-Fi

®

 (Wireless)

1.  On the display select 

Wi-Fi

®

 Network

.

2.   Select the network the CAPXM will use.
3.  Enter the password for the network.
4. Select 

Login

.

Additional compatibility considerations: 
•  When checking signal strength in CAPXM admin mode, we 

recommend at least two bars.

•  If two bars are not available, relocate the router, the antenna or use accessory WFAEXT (Wi-Fi

®

 Antenna Extension Kit – 15') to 

move the CAPXM antenna higher up or to a location resulting in two or more bars.

•  If using a Wi-Fi

®

 signal strength tool or app, a continuous Wi-Fi

®

 signal strength connection 

of at least -65 dBm (numbers closer to zero are stronger strength) at the CAPXM must be 

guaranteed to ensure an acceptable connection to the local network.

•  Hidden network SSIDs are not supported. The network must be selectable from the CAPXM 

display.

•  Wi-Fi

®

 networks requiring secondary authentication are not supported (E.g. Hotels and airport Wi-Fi

®

).

LAN on 

Control Board

Modem

Router/Switch

Ethernet Cable

(325 feet [99.1 m] maximum)

Admin

-30 to -67

dBm

GOOD

-66 to -85

dBm

POSSIBLE

 -86

dBm

POOR

-30 to -67

dBm

GOOD

-66 to -85

dBm

POSSIBLE

 -86

dBm

POOR

-30 to -67

dBm

GOOD

-66 to -85

dBm

POSSIBLE

 -86

dBm

POOR

Summary of Contents for myQ Business CAPXM

Page 1: ...1 myQ Business Smart Video Intercom M INSTALLATION MANUAL Model CAPXM...

Page 2: ...ress push buttons may not be legal Single action exits may be required ALWAYS obtain proper permits and approvals in writing BEFORE installing equipment DO NOT INSTALL THE SYSTEM IN THE FAIL SECURE MO...

Page 3: ...7 Tools Needed 7 Dimensions 8 System Specifications 8 Wire Specifications 9 Internet Requirements 10 PRE INSTALL 1 Setup a myQ Business Account 11 INSTALL 2 Remove Knockouts 12 Mount the CAPXM 13 Ins...

Page 4: ...NTRODUCTION PRE INSTALL NETWORK INSTALL ACCESS CONTROL CAPXM Overview Smart Video Intercom M Model CAPXM is a cloud based access control solution that includes an integrated video camera enabling adva...

Page 5: ...N PRE INSTALL NETWORK INSTALL ACCESS CONTROL INTRODUCTION PRE INSTALL NETWORK INSTALL ACCESS CONTROL INTRODUCTION PRE INSTALL NETWORK INSTALL ACCESS CONTROL Control Board Overview Power Expansion Wi F...

Page 6: ...1 Gated Operator Door Strikes Maglocks Lights for control only power to be provided by external power supply Alarm Shunt Relay Output 2 Wiegand Output 1 Standard 26 bit 30 bit Wiegand HID 37 bit with...

Page 7: ...ACCESS CONTROL INTRODUCTION INTRODUCTION PRE INSTALL NETWORK INSTALL ACCESS CONTROL INTRODUCTION PRE INSTALL NETWORK INSTALL ACCESS CONTROL INTRODUCTION PRE INSTALL NETWORK INSTALL ACCESS CONTROL INTR...

Page 8: ...n Air Line of Sight to front of panel range will vary depending on obstructions Built in LiftMaster Passport Receiver Security 2 0 Wireless Communication to Gate Operator Up to 750 feet 228 6 m Open A...

Page 9: ...nduits must be UL approved for low and high voltage Refer to the NEC for additional wiring requirements Category 5e cabling is the minimum performance category recommended Wiring shall be in accordanc...

Page 10: ...DERATIONS DO NOT use Wi Fi extender devices These may introduce latency in the connection leading to choppy or loss of reliable video transmission If using a Wi Fi signal strength tool or app a contin...

Page 11: ...ng the information required on the Installation Readiness Survey 2 You will get a welcome email from LiftMaster Accept the invitation and register or login to your account 3 Setup the facility select...

Page 12: ...by laying down a cloth or other protective material 2 Lay the CAPXM face down on the protective material 3 Identify which knockouts need to be removed based on your application 4 Use a center punch t...

Page 13: ...ter the installation is complete Allow 1 8 in 3 175 mm of space between the bottom of CAPXM and the wall if flush mounting CAPXM without the trim kit ADA Compliance When mounting the CAPXM at a pedest...

Page 14: ...Run the wire from the CAPXM to suitable earth ground NOTE Shield connections on boards should not be connected to main earth ground connection Ground wire 12 AWG minimum Earth ground rod Other ground...

Page 15: ...output wires on the power supply Black is negative and red is positive 2 Remove the PWR INPUT terminal block from the Control Board 3 Connect the power supply wires to the PWR INPUT terminal block red...

Page 16: ...l board will light flicker the control board is located on the back of the CAPXM display If the green LED is not lit check the connections on the CAPXM and the Ethernet hub 2 On the display select Wir...

Page 17: ...For AC Power Install a Siemens S10K30MOV Metal Oxide Varistor provided or equivalent REQUEST TO EXIT GROUND STATUS NORMALLY OPEN COMMON COMMON NORMALLY CLOSED NORMALLY CLOSED COMMON OR DOOR 1 or 2 RE...

Page 18: ...ts tab Then select the desired relay on the left hand side 1 through 4 3 Press LEARN button on gate operator Press and release the LEARN button on the primary operator The green XMITTER LED will light...

Page 19: ...nshielded wires should be kept to a minimum to avoid electrical noise RED LED brown GREEN LED orange DATA 1 white DATA 0 green GROUND black 12Vdc red READER OR KEYPAD WIEGAND LIGHT LOAD LINE NEUTRAL I...

Page 20: ...DC 1 Amp max Green White Yellow White The gray blue and brown wires from the RFID Reader are unused Green Black DOOR BOARD Door 1 Door 2 WIEGAND INPUT PRIMARY RELAY AUXILIARY RELAY AUXILIARY RELAY REQ...

Page 21: ...f the resident that granted access And Or Successful access through Entry Code The CAPXM will provide a myQ Business specified facility code followed by the successful Entry Code And Or Successful acc...

Reviews: