Chamberlain LM3800TXSA Manual Download Page 9

8-en

EMERGENCY DOOR RELEASE

ADJUSTMENT STEP 6

To Open the Door Manually

Disengage door lock before proceeding. The door should be fully closed if possible. Pull down on the emergency release handle until a click noise is
heard from the unit and lift the door manually. To reconnect the door to the operator, pull down the emergency release handle straight down a second
time until a click noise is heard from the unit. The door will reconnect on the next UP or DOWN operation.

Test the emergency release:

• Make sure the door is closed.

• Pull the emergency release handle. The door should then be able to be opened manually.

• Return the door to the closed position.

• Pull the emergency handle a second time.

• Reconnect the door to the operator.

To prevent possible SERIOUS INJURY or DEATH from a falling door:

• If possible, use emergency release handle to disengage door ONLY when door is CLOSED. Weak or broken springs or unbalanced door could

result in an open door falling rapidly and/or unexpectedly.

• NEVER use emergency release handle unless the doorway is clear of persons and obstructions.

3

3

Using Your Door Opener

Your operator and hand-held remote control have been factory-set to a
matching code which changes with each use, randomly accessing over
100 billion new codes. Your operator will operate with up to 64 remote
controls and one Keyless Entry System. If you purchase a new remote, 
or if you wish to deactivate any remote, follow the instructions in the

Programming

section.

Activate your operator with any of the following:

The hand-held Remote Control:

Hold top middle button down until the

door starts to move.

The wireless wall control 128LM 

press and hold the large round button

down until the door starts to move.

The Keyless Entry (See Accessories):

If provided with your door

operator, it must be programmed before use. See 

Programming.

When the operator is activated (with the safety reversing sensor
correctly installed and aligned)

1. If open, the door will close. If closed, it will open.

2. If closing, the door will stop.

3. If opening, the door will stop.

4. If the door has been stopped in a partially open position, it will close.

5. If obstructed while closing, the door will reverse. If the obstruction

interrupts the sensor beam, the operator wil click for five seconds.

6. If obstructed while opening, the door will stop.

7. If fully open, the door will not close when the beam is broken. The

sensor has no effect in the opening cycle.

If the sensor is not installed, or is misaligned, the door won’t close from a
hand-held remote. However, you can close the door with the Door
Control, the Outside Keylock, or Keyless Entry, 

if you activate them until

down travel is complete. 

If you release them too soon, the door will

reverse. 

3

5

3

4

Automatic Close Timer Function

Note:

Requires the Chamberlain Protector System (IR-sensors) to be

installed. If Protector System (IR-sensors) is installed only to enable the
timer to close function (first time), install Sensors close to garage door
and wait for 5 minutes. 
A Multi-function Door Control (78LM) is required to enable and disable
the auto-close function.

Enable:

Push and hold lock button on the Multi-function Door Control

until the electric lock toggled twice. At the same time watch the LED light
in the center of the actuator button from the Multi-function Door Control.
1x blink 10 seconds Auto-Close
2x blink 45 seconds Auto-Close
3x blink 2 minutes Auto-Close
4x blink 3 minutes Auto-Close
5x blink OFF Auto-Close 
Factory setting is OFF. Repeat the procedure until the Multi-function Door
Control shows the required number of blinks. 

CARE OF YOUR OPENER

MAINTENANCE SCHEDULE

Once a Month

• Manually operate door. If it is unbalanced or binding, call a trained door

systems technician.

• Check to be sure door opens & closes fully. Adjust limits and/or force if

necessary (see Adjustment Steps 1 and 2).

• Repeat the safety reverse test. Make any necessary adjustments (see

Adjustment Step 5).

Once a Year

• Oil door rollers, bearings and hinges. The operator does not require

additional lubrication. Do not grease the door tracks.

OPERATION 

Summary of Contents for LM3800TXSA

Page 1: ...Garage Door Operator Model LM3800TXSA Chamberlain GmbH Alfred Nobel Strasse 4 D66793 Saarwellingen www liftmaster eu info liftmaster eu Optional Accessory Available en ar LM3800TXSA...

Page 2: ...oor balanced Do not let the garage door opener compensate for a binding or sticking garage door Sticking or binding doors must be repaired Garage doors door springs cables pulleys brackets and their h...

Page 3: ...uded in the carton This operator is compatible with Doors that use a torsion bar springs and a door no more than 4 2m high 80mm 178mm drums NOT TO BE USED on tapered drums over 152mm High lift and sta...

Page 4: ...w 8x1 2x Self Tapping Screw 10 32 4x Wall Anchor 6x Handle 1x Rope 1x Insulated Staples 20x Bracket 2x Bit 1x Bell Wire 093B0867 5 6 ASSEMBLY STEP 1 Attach the Collar to the Motor Unit To avoid instal...

Page 5: ...erator by sliding the collar over the torsion bar until pilot holes align with bracket Securely tighten collar screws that attach to the torsion bar to 16Nm 19Nm of torque Securely tighten both set sc...

Page 6: ...h conduit cut to proper length and strip insulation Attach with wire nuts not provided Properly secure wire under plastic ties so that wire does not come in contact with moving parts Reinstall the cov...

Page 7: ...parate refer to FLA230 manual Connection of Door in Door Switch 16200LM optional accessory Prevents operator from starting if door in door is open See drawing for wiring Additional material is require...

Page 8: ...ld be protruding through the track Operate the door in the open direction The power door lock should retract before the door begins to move Operate the door in the down direction When the door reaches...

Page 9: ...d aligned 1 If open the door will close If closed it will open 2 If closing the door will stop 3 If opening the door will stop 4 If the door has been stopped in a partially open position it will close...

Page 10: ...ensor Short travel 150 200mm Unplug unit to reset Try to operate motor unit check diagnostic code If it is still flashing 5 times and motor unit moves 150 200mm 6 8 The unit s APE Absolute Positioning...

Page 11: ...f not move the position of the mounting bracket 15 Power lock makes noise when operating Call Chamberlain Liftmaster dealer for replacement power lock TROUBLESHOOTING 1 The operator doesn t operate fr...

Page 12: ...oise level 57dB Travel Rate 24rpm down 36rpm up Safety Personal Push button and automatic stop in down direction Push button and automatic stop in up direction Electronic Automatic force adjustment El...

Page 13: ...ar E1702 2 3 50 TheProtector System 40 400 1 5...

Page 14: ...2 ar EverCharge Protector System Protector System 4 2 80 178 152 4 2 5 5 16 2 25 1 64 76 205 25 100 1 CM475 EverChargeTM SPU 5 2 2 1...

Page 15: ...3 ar 1 2 3 2 1 1 16 19 8 1 480LM LM3800A 14 10 x1 7 8 6 x 1 2 8 x1 2 10 32 4 6 1 1 20 2 1 3 4 6 5 9 9a 6 093B0867...

Page 16: ...4 ar 1 2 3 4 5 1 8 6 7 8 1 5 9 10 11 50 1 2 1 2 3 1 5 2 1 2 3 4 25 1 8 4 16 19 3 5 1 2 3 8 4 5 6 3 11 10 12 13 14 15...

Page 17: ...5 ar 22 1 3 7 6 o 4 90 22 1 1 6 128 LM 1 5 3800 128 LM 128 LM 2 25 1 2 8 2 1 5 5 3 5 16 3 4 5 6 5 1 2 6 1 4 4 1 2 3 4 5 32 6 5 1 2 16 17 18 19 20 21...

Page 18: ...LA230 16200 LM 7 Evercharge SPU CM475 1 SPU 80 2 SPU SPU SPU SPU 2 SPU SPU 3 CM475 SPU 4 5 6 16 1 7 1 7 2 50 8 Protector System 400 40 Protector System 400 The Protector System The Protector System ar...

Page 19: ...7 ar 2 1 2 LED 3 LED 3 3 9 5 50 1 2 1 4 x 2 4 1 2 50 1 2 1 4 x 2 3 4 4 32 30 31...

Page 20: ...6 100 64 128 LM 1 2 3 4 5 6 7 Chamberlain Protector System IR Chamberlain Protector System IR 5 78 LM LED 1 10 45 3 4 3 5 1 2 5 ar 8 33 34 35...

Page 21: ...LED 3 4 LED 5 RPM 9 30 60 LED RPM 150 200 5 150 200 6 8 APE Chamberlain 1 LED 30 2 LED 30 3 30 LED 4 LED 5 LED ar 9 36 37 38...

Page 22: ...LED 6 9 1 2 LED LED LED LED 3 4 5 6 7 4 9 2 8 LED 4 2 9 LED 5 10 11 12 EverCharge 20 13 1 2 1 14 15 Chamberlain Liftmaster www liftmaster eu ar 10...

Page 23: ...9747 E 4 78 LM 5 770 EV The Protector System 6 FLA1 LED 7 16200 LM 230 240 50 40 145 5 10 57 24 36 4 2 14 5 5 16 11 64 433 92 Chamberlain Protector System ar 11 39 40 41 220 240 Volt 50 60Hz E53349 1...

Page 24: ...114A4864B...