background image

2-en

I

NTRODUCTION

Safety symbol review and signal word review  . . . . . . . . . . . . . . . . . . . . .
Planning   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Preparing your door  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tools  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Carton inventory  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hardware inventory  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

ASSEMBLY

Attach the collar to the motor unit  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Attach mounting bracket to the motor unit  . . . . . . . . . . . . . . . . . . . . . . . .

INSTALLATION 

Installation safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Position the operator  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Attach the emergency release rope and handle  . . . . . . . . . . . . . . . . . . .
Install the power door lock  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Attach the cable tension monitor (Required)  . . . . . . . . . . . . . . . . . . . . . .
Electrical requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Install the wireless wall control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Auxiliary inputs  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mount the EverCharge unit (SPU) (not provided)  . . . . . . . . . . . . . . . . . .
Install The Protector System

®

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

ADJUSTMENT

Program the travel limits
Setting the force
Test cable tension monitor
Test power door lock

Test the safety reversal system  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Test The Protector System

®

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

To open door manually . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

OPERATION 

Operation safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using your door operator  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Care of your operator  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using the remote control  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Diagnostics chart  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Replacing the battery  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PROGRAMMING

To add or reprogram a hand-held remote control  . . . . . . . . . . . . . . . . . .
To erase all codes from motor unit memory . . . . . . . . . . . . . . . . . . . . . . .
To program wireless keypads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TROUBLESHOOTING  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

REPAIR PARTS 

Installation parts  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Motor unit assembly parts  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TECHNICAL DATA

WARRANTY

TABLE OF CONTENTS

Planning

Survey the area to see if any of the conditions below apply to your
installation. Additional materials may be required. You may find it helpful
to refer back to this page as you proceed with the installation of your
operator.

Depending on your requirements, there are several installation steps
which may call for materials or hardware not included in the carton.

This operator is compatible with:

• Doors that use a torsion bar, springs and a door no more than 4,2m

high.

• 80mm - 178mm drums , 

NOT TO BE USED

on tapered drums over

152mm.

• High lift and standard lift sectional doors up to 4,2m high.

• Doors up to 5.5m wide.

• Doors up to 16m2

• 25mm (1”) torsion bar only.

• Review or inspect proposed installation area. Opener can be installed

on left or right side of door. Select the side that meets the
requirements listed below.

• Must have minimum of 64mm between the  wall and the center of the

torsion bar.

• Must have minimum of 76mm between the ceiling and the center of

torsion bar.

• Must have minimum of 205mm between the side  wall (or obstruction)

and the end of torsion bar.

• The torsion bar must extend at least 25mm to 100mm past the

bearing plate.

• An electric outlet is required within 1m of the installation area. If outlet

does not exist, contact a qualified electrician.

• Depending upon building’s construction, extension brackets or wood

blocks may be needed to install safety reversing sensors.

• A model CM475 EverCharge

TM

Standby Power Unit (SPU) is strongly

recommended if there is no access door to the building, as this
operator cannot be used in conjunction with an external emergency
release mechanism.

• Any gap between the floor and the bottom of the door must not

exceed 5mm. Otherwise the safety reversal system may not work
properly.

• Cannot be used with reversed drums (see picture         ).

NOTE:

Inspect the torsion bar while the door is raised and lowered. It is

important that there is no noticeable movement up and down or left and
right. If this type of movement is not corrected, life of this operator will be
greatly reduced.

1

2

2

Install The

 Rain Cover

  

. . . . 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of Contents for LM3800TXSA

Page 1: ...Garage Door Operator Model LM3800TXSA Chamberlain GmbH Alfred Nobel Strasse 4 D66793 Saarwellingen www liftmaster eu info liftmaster eu Optional Accessory Available en ar LM3800TXSA...

Page 2: ...oor balanced Do not let the garage door opener compensate for a binding or sticking garage door Sticking or binding doors must be repaired Garage doors door springs cables pulleys brackets and their h...

Page 3: ...uded in the carton This operator is compatible with Doors that use a torsion bar springs and a door no more than 4 2m high 80mm 178mm drums NOT TO BE USED on tapered drums over 152mm High lift and sta...

Page 4: ...w 8x1 2x Self Tapping Screw 10 32 4x Wall Anchor 6x Handle 1x Rope 1x Insulated Staples 20x Bracket 2x Bit 1x Bell Wire 093B0867 5 6 ASSEMBLY STEP 1 Attach the Collar to the Motor Unit To avoid instal...

Page 5: ...erator by sliding the collar over the torsion bar until pilot holes align with bracket Securely tighten collar screws that attach to the torsion bar to 16Nm 19Nm of torque Securely tighten both set sc...

Page 6: ...h conduit cut to proper length and strip insulation Attach with wire nuts not provided Properly secure wire under plastic ties so that wire does not come in contact with moving parts Reinstall the cov...

Page 7: ...parate refer to FLA230 manual Connection of Door in Door Switch 16200LM optional accessory Prevents operator from starting if door in door is open See drawing for wiring Additional material is require...

Page 8: ...ld be protruding through the track Operate the door in the open direction The power door lock should retract before the door begins to move Operate the door in the down direction When the door reaches...

Page 9: ...d aligned 1 If open the door will close If closed it will open 2 If closing the door will stop 3 If opening the door will stop 4 If the door has been stopped in a partially open position it will close...

Page 10: ...ensor Short travel 150 200mm Unplug unit to reset Try to operate motor unit check diagnostic code If it is still flashing 5 times and motor unit moves 150 200mm 6 8 The unit s APE Absolute Positioning...

Page 11: ...f not move the position of the mounting bracket 15 Power lock makes noise when operating Call Chamberlain Liftmaster dealer for replacement power lock TROUBLESHOOTING 1 The operator doesn t operate fr...

Page 12: ...oise level 57dB Travel Rate 24rpm down 36rpm up Safety Personal Push button and automatic stop in down direction Push button and automatic stop in up direction Electronic Automatic force adjustment El...

Page 13: ...ar E1702 2 3 50 TheProtector System 40 400 1 5...

Page 14: ...2 ar EverCharge Protector System Protector System 4 2 80 178 152 4 2 5 5 16 2 25 1 64 76 205 25 100 1 CM475 EverChargeTM SPU 5 2 2 1...

Page 15: ...3 ar 1 2 3 2 1 1 16 19 8 1 480LM LM3800A 14 10 x1 7 8 6 x 1 2 8 x1 2 10 32 4 6 1 1 20 2 1 3 4 6 5 9 9a 6 093B0867...

Page 16: ...4 ar 1 2 3 4 5 1 8 6 7 8 1 5 9 10 11 50 1 2 1 2 3 1 5 2 1 2 3 4 25 1 8 4 16 19 3 5 1 2 3 8 4 5 6 3 11 10 12 13 14 15...

Page 17: ...5 ar 22 1 3 7 6 o 4 90 22 1 1 6 128 LM 1 5 3800 128 LM 128 LM 2 25 1 2 8 2 1 5 5 3 5 16 3 4 5 6 5 1 2 6 1 4 4 1 2 3 4 5 32 6 5 1 2 16 17 18 19 20 21...

Page 18: ...LA230 16200 LM 7 Evercharge SPU CM475 1 SPU 80 2 SPU SPU SPU SPU 2 SPU SPU 3 CM475 SPU 4 5 6 16 1 7 1 7 2 50 8 Protector System 400 40 Protector System 400 The Protector System The Protector System ar...

Page 19: ...7 ar 2 1 2 LED 3 LED 3 3 9 5 50 1 2 1 4 x 2 4 1 2 50 1 2 1 4 x 2 3 4 4 32 30 31...

Page 20: ...6 100 64 128 LM 1 2 3 4 5 6 7 Chamberlain Protector System IR Chamberlain Protector System IR 5 78 LM LED 1 10 45 3 4 3 5 1 2 5 ar 8 33 34 35...

Page 21: ...LED 3 4 LED 5 RPM 9 30 60 LED RPM 150 200 5 150 200 6 8 APE Chamberlain 1 LED 30 2 LED 30 3 30 LED 4 LED 5 LED ar 9 36 37 38...

Page 22: ...LED 6 9 1 2 LED LED LED LED 3 4 5 6 7 4 9 2 8 LED 4 2 9 LED 5 10 11 12 EverCharge 20 13 1 2 1 14 15 Chamberlain Liftmaster www liftmaster eu ar 10...

Page 23: ...9747 E 4 78 LM 5 770 EV The Protector System 6 FLA1 LED 7 16200 LM 230 240 50 40 145 5 10 57 24 36 4 2 14 5 5 16 11 64 433 92 Chamberlain Protector System ar 11 39 40 41 220 240 Volt 50 60Hz E53349 1...

Page 24: ...114A4864B...