Installing the Multi-function Door Control
(78LM Optional Accessory):
Press the white square to open or close the door. Press again to stop the
door while it is moving.
Light Feature:
Press the Light button to turn the opener light on or off. If
you turn it on and then activate the opener, the light will remain on for 2-
1/2 minutes. Press again to turn it off sooner. The Light button will not
control the opener lights when the door is in motion.
Lock Feature:
Prevents operation of the door from portable remote
controls. However, the door will open and close from the Door Control
push button, the Outside Keylock and the Keyless Entry Accessories.
•
To activate:
Press and hold the Lock button for 2 seconds. The push
button light will flash as long as the Lock feature is
on.
•
To turn off:
Press and hold the Lock button again for 2 seconds. The
push button light will stop flashing. The Lock feature will also turn off
whenever the “LEARN” button on the control panel is activated.
22
INSTALLATION STEP 7
Mounting the Evercharge Standby Power Unit
(SPU) (OPTIONAL)
If the optional CM475 Standby power supply unit is part of this installation
it should be installed at this time (1).
• The SPU can be mounted to either the ceiling or a wall within 80cm of
the motor unit (2).
• Position the SPU as desired to a structural support (ceiling joist or wall
stud).
• Attach the SPU to the support using the mounting holes on either side
of the SPU.
• Secure the SPU using the lag screws (2) provided with the SPU unit.
• Connect the SPU cord into the connector on the bottom of the motor
unit (3).
• Follow all instructions included with the CM475 unit to test for proper
operation and testing of the SPU
.
INSTALLATION STEP 8
Install the Protector System™ (optional)
23
The force, as measured on the closing edge of the door, should not
exceed 400 N (40kg). If the closing force is more than 400 N, the
Protector System must be installed.
After opener has been installed and adjusted,
The Protector System™
accessory can be installed. Instructions are included with this accessory.
The Protector System™ provides an additional measure of safety
against a small child being caught under a garage door.
It uses an invisible beam which, when broken by an obstruction, causes
a closing door to open and prevents an open door from closing and is
strongly RECOMMENDED for homeowners with young children.
FLASHING LAMP AND DOOR-IN-DOOR
SWITCH
Connection of Flashing Lamp
(FLA230 optional accessory)
Mount lamp as high and as visible as possible on outside garage wall.
See drawings for wiring. Power supply is separate (refer to FLA230
manual).
Connection of Door-in-Door Switch
(16200LM optional accessory)
Prevents operator from starting if door-in-door is open. See drawing for
wiring. Additional material is required (e.g. spiral cable).
21b
INSTALLATION STEP 8
Install the Protector System™ (optional)
23
INSTALLATION STEP
9
Install the
Rain Cover
(optional)
Position rain cover over the RJO and press down firmly until cover clips
are in place.
2
4
INSTALLATION STEP
9
Install the
Rain Cover
(optional)
Position rain cover over the RJO and press down firmly until cover clips
are in place.
2
4
Program the Travel Limits
Travel limits regulate the points at which the door will stop when
moving up or down. Follow the steps below to set the limits.
NOTE
: Cable Tension Monitor must be installed
To program the travel limits:
Adjust the position of the door by using the black and orange buttons.
Black moves the door UP
(open) and orange moves the door DOWN
(close).
ADJUSTMENT STEP
1
2
5
2
6
2
7
2
8 29
1.
Setting the UP
position:
Press and hold the black button until the
yellow indicator light starts flashing slowly then release.
2.
Push and hold the black button until the door reaches the desired UP
(open) position.
NOTE:
Check to be sure the door opens high enough for your vehicle.
3. Push the remote control or door control. This sets the UP (open) limit
and begins closing the door.
NOTE:
Excessive movement of the motor unit will cause premature
wear. See Troubleshooting section.
4. Immediately when the door begins to move down, press and release
either the black or orange button. This will stop the door.
5.
Setting the DOWN position:
Push and hold the orange button until
the door reaches the desired DOWN (closed) position.
6. Once the door is closed, check for proper pressure on the door (you
should be able to manually push the door down a 1/16 of an inch). If
there appears to be too much pressure on the door, you may toggle
the door back and forth using the black and orange buttons to reach
the desired position.
7. Push the remote control or the door control. This sets the DOWN
(close) limit and should bring the door to the open position.
• If the operator is not stopping exactly where you would like it, repeat
steps 1 through 7 and program the limits again
.
• When the unit stops in both the desired up (open) and down (close)
positions, proceed to
Adjustment Step 2, Setting the Force.
• NEVER learn forces or limits when door is binding or sticking.
Repair door first.
• Incorrect adjustment of the door travel limits will interfere with
proper operation of safety reversal system.
• After ANY adjustments are made, the safety reversal system MUST
be tested. Door MUST reverse on contact with 50mm high object on
floor.
To prevent damage to vehicles, be sure fully open door provides