background image

15

ENABLE TELCO MODE

Enter the command tone: 

 

 

0

 

7

PROGRAMMING 

>> FROM THE TELEPHONE

ENABLE INTERCOM MODE

Enter the command tone: 

 

 

0

 

3

ADJUST “PICK UP” RING COUNT

1. Enter the command tone: 

 

 

1

 

0

2. Enter the ring count: 

2

 through 

5

ENABLE ALTERNATE DTMF PROGRAMMING

This feature changes the first programming digit from 

 to 

#

Enter the command tone: 

 

 

1

 

3

DISABLE ALTERNATE DTMF PROGRAMMING

Enter the command tone: 

#

 

 

1

 

6

ENABLE STANDARD (LONG) RING TONE

Enter the command tone: 

 

 

1

 

4

ENABLE ALTERNATE (DUAL) RING TONE (DEFAULT)

Enter the command tone: 

 

 

1

 

5

ERASE THE CALL FORWARDING NUMBER

Enter the command tone: 

 

 

#

 

8

ENABLE CALL FORWARDING

Enter the command tone: 

 

 

0

 

1

DISABLE CALL FORWARDING

Enter the command tone: 

 

 

0

 

2

VERIFY CALL FORWARDING NUMBER (VIA CALLER ID)

Enter the command tone: 

 

 

0

 

6

Hang up the phone - Wait for the ring.

TELEPHONE PROGRAMMING

CALL FORWARD PROGRAMMING

Up to a 14 Digit Telco Number

ENTER CALL FORWARDING TELEPHONE NUMBER

Enter the command tone:  

 

#

   

#

Summary of Contents for LiftMaster TAC1

Page 1: ...Installation and Programming Manual 8 9 7 0 2 3 1 5 6 4 The Chamberlain Group 845 Larch Ave Elmhurst IL 60126 1196 www liftmaster com TAC1 Telephone Entry System ...

Page 2: ...ing a Gate Operator and a Door Strike Lock 8 Wiring a Gate Operator and a Maglock 8 Wiring a Door Strike Lock 9 Wiring a Maglock 9 Earth Ground Rod 10 Power Wiring 10 Plug the Transformer into the Outlet 11 Mount the Unit 11 Set the Master Code 11 TESTING 12 Test the Gate Door Relay 12 Test the Telephone Connections 12 PROGRAMMING 13 19 From the TAC1 Keypad 13 Code Setup and Code Operation 14 From...

Page 3: ...eded 2 Conductor Cable See device specifications for wire size From the Earth ground to processor board 12 AWG copper wire PVC insulated or 12 AWG copper wire uninsulated Belden 9912 Belden 8011 Residence and Telco phone lines 24 AWG twisted pair telephone wire Shielded Belden 9502 From the Processor Board 24 AWG twisted pair telephone wire Shielded Belden 9502 Between Processor Boards on multiple...

Page 4: ...Input Telephone input connection from Telco service provider 4 Relay 1 Output Form C primary control relay 12 Relay 1 Primary Output Status LED 13 Relay 2 Secondary Output Status LED 10 Voice Data Send Status LED 9 Status LED 11 Power Status LED 8 Choose the mounting location for the unit Remove the back panel and attach the unit to a solid surface or post hardware not provided INSTALLATION MOUNT ...

Page 5: ... black or yellow wires they have been replaced by white blue blue white white orange and orange white If the wire is primarily orange with white stripes then that color is orange white Refer to the table below The NID labels will most likely have the old coloring scheme on them and most telephone wiring components you can purchase will still reflect the original colors NOTE If the unit will be con...

Page 6: ...ommunication between the unit and the resident s phones PHONE LINE TIP RING TIP RING Ring Ring Ring Ring Tip Telco Entrance Box Demarcation Point Telco Tip Tip Tip Ringer Equivalence Number REN 5 INSTALLATION WIRING THE UNIT WITH A TELCO LINE AND WIRING THE UNIT WITHOUT A TELCO LINE Never run data wires and high voltage wires in the same conduit The high voltage wires may interfere with the data w...

Page 7: ...out configuring Relays 1 and 2 The Auto Call feature will enable the unit to contact the resident when a driveway sensor or any device that provides a contact closure is activated WIRING AN AUTO CALL SENSOR INSTALLATION WIRING A GATE OPERATOR NORMALLY OPEN AND WIRING AN AUTO CALL SENSOR AU TO CA LL EX IT 2 CO M EX IT 1 HOUSE TELCO Notes about wire connectors terminal blocks Wire connectors can be ...

Page 8: ... for information about configuring Relays 1 and 2 AU TO CA LL EX IT 2 CO M EX IT 1 HOUSE TELCO Notes about wire connectors terminal blocks Wire connectors can be removed to simplify wiring DO NOT overload wire connectors Use ONLY one wire per hole INSTALLATION WIRING A GATE OPERATOR NORMALLY OPEN A DOOR STRIKE LOCK NORMALLY OPEN AND WIRING A GATE OPERATOR NORMALLY OPEN A MAGLOCK NORMALLY CLOSED NO...

Page 9: ...ck AC or DC Power Maglock COM Common NC Normally Closed WIRING A MAGLOCK NORMALLY CLOSED The door strike can be connected to Relay 1 or Relay 2 See the Programming section for information about configuring Relays 1 and 2 The maglock can be connected to Relay 1 or Relay 2 See the Programming section for information about configuring Relays 1 and 2 INSTALLATION WIRING A DOOR STRIKE LOCK NORMALLY OPE...

Page 10: ...Room 1 Conference Rm 2 3 Refer Bus 1 2 3 Conference Room 2 o C p m Ser e v 2 o C p m Serve 1 12 Vac Power included Dedicated Outlet Dedicated 10 Amp Minimum Circuit Breaker TAC 1 NOTE Chamberlain is not responsible for conflicts between the information listed in the above table and the requirements of local building codes The information is for suggested use only Check local building codes before ...

Page 11: ...f the TAC1 The Master Code should not be distributed as a User Code Mount the unit onto the back panel Lock the unit with the key Plug the transformer into the 110 Vac outlet Write down the Master Code and store in a secure location INSTALLATION PLUG THE TRANSFORMER INTO THE OUTLET MOUNT THE UNIT AND SET THE UNIT MASTER CODE 8 9 7 0 2 3 1 5 6 4 SET THE UNIT MASTER CODE NOTE The star button acts as...

Page 12: ... To test Relay 2 have someone answer the telephone and enter 5 Star 5 The TAC1 will disconnect the call as soon as the relay is activated TEST THE TELEPHONE CONNECTIONS TEST GATE DOOR RELAYS TEST RELAY 1 TEST RELAY 2 Enter 4 digit Master Code 1 Key The 1 Key indicates the Relay to be triggered Enter 4 digit Master Code 2 Key The 2 Key indicates the Relay to be triggered NOTE Relay 1 status indicat...

Page 13: ...ime in seconds the relay remains active Default level is 0 5 seconds 1 Enter the Master Code 2 Enter the Program Code 0 2 5 3 Enter the Output Time in seconds Example 0000 0 5 Seconds Minimum 0010 10 Seconds 8000 8000 Seconds Maximum ENABLE TELCO MODE Telco Mode is using the main telephone line for the unit s communications to the house or complex 1 Enter the Master Code 2 Enter the Program Code 0...

Page 14: ...TEMPORARY 1 SHOT USER CODE NUMBER The TAC1 holds 1 temporary User Code 1 Enter the Master Code 2 Enter the Program Code 5 1 The unit will beep 3 Enter the Temporary User Code ENGAGE PARTY MODE RELAY 1 Party Mode will latch relay and trigger corresponding channel 1 Enter the Master Code 2 Enter the Program Code 5 4 To disengage party mode Enter a valid code into the TAC1 keypad or enter 9 into the ...

Page 15: ...RAMMING Enter the command tone 1 6 ENABLE STANDARD LONG RING TONE Enter the command tone 1 4 ENABLE ALTERNATE DUAL RING TONE DEFAULT Enter the command tone 1 5 ERASE THE CALL FORWARDING NUMBER Enter the command tone 8 ENABLE CALL FORWARDING Enter the command tone 0 1 DISABLE CALL FORWARDING Enter the command tone 0 2 VERIFY CALL FORWARDING NUMBER VIA CALLER ID Enter the command tone 0 6 Hang up th...

Page 16: ...Y MODE RELAY 1 Enter the command tone 0 4 To disengage party mode Enter 9 into the local telephone ENABLE DO NOT DISTURB MODE Enter the command tone 1 1 TELEPHONE COMMANDS FROM LOCAL TELEPHONE FROM FORWARDED TELEPHONE 1 Locate the receiver Refer to the gate or door operator manual for information about the location of the learn button 2 Press and release the learn button on the receiver The indica...

Page 17: ...e Level 2 Master Code 4 digits 06 Volume Level 1 Low 2 Medium or 3 High 07 Microphone Sensitivity Level 2 Master Code 4 digits 07 Volume Level 1 Low 2 Medium or 3 High 09 Change the Master Code Master Code 4 digits 09 New Master Code 4 digits 51 Create Temporary 1 Shot Code Master Code 4 digits 51 New Temporary 1 Shot Code 4 digits 52 Enable Vacation Lock Down Mode Disabled Master Code 4 digits 52...

Page 18: ...Telephone Number Up to 14 digits DIRECT COMMANDS FROM THE LOCAL TELEPHONE PROGRAMMING NUMBER DESCRIPTION OF TASK FACTORY SETTING PROGRAMMING PROCEDURE 5 Triggers Relay 2 5 9 Triggers Relay 1 9 04 Enable Party Latched Mode Relay 1 04 05 Disable Party Latched Mode Relay 1 11 Enable Do Not Disturb Mode Disabled 11 12 Disable Do Not Disturb Mode 12 DIRECT COMMANDS FROM THE FORWARDED TELEPHONE PROGRAMM...

Page 19: ...19 TAC1 MASTER CODE Write down the Master Code and store in a secure location ...

Page 20: ...warranty period this product appears to contain a defect covered by this limited warranty call 1 800 528 2806 before dismantling this product Then send this product pre paid and insured to our service center for warranty replacement Products returned to Seller for warranty replacement which upon receipt by Seller are confirmed to be defective and covered by this limited warranty will be replaced a...

Reviews: