background image

3

The same type of device shall not be used for both entrapment 
protection means. Use of a single device to cover both the opening 
and closing directions is in accordance with the requirement; 
however, a single device is not required to cover both directions.
This operator is provided with Type A. The installer is required to 
install additional entrapment protection devices in each entrapment 
zone. 

HORIZONTAL SLIDE AND SWING GATE OPERATOR

GATE OPERATOR ENTRAPMENT PROTECTION TYPES

Type A

Inherent (built into the operator) entrapment 

protection system

Type B1

Non-contact sensors such as photoelectric sensors

Type B2

Contact sensors such as edge sensors

SAFETY

UL325 ENTRAPMENT PROTECTION REQUIREMENTS

This vehicular gate/door operator must be installed with at least two independent entrapment protection means as specified in the table below.

To reduce the risk of SEVERE INJURY or DEATH:
•   READ AND FOLLOW ALL INSTRUCTIONS.
•   NEVER let children operate or play with gate/door controls. Keep 

remote controls away from children.

•   ALWAYS keep people and objects away from the gate/door. NO ONE 

SHOULD CROSS THE PATH OF THE MOVING GATE/DOOR.

•   Test the gate/door operator monthly. The gate/door MUST reverse 

on contact with a rigid object or reverse when an object activates the 
non-contact sensors. After adjusting the force or the limit of travel, 
retest the gate/door operator. Failure to adjust and retest the 
operator properly can increase the risk of severe INJURY or DEATH.

•   Use the emergency release ONLY when the gate/door is closed. Use 

caution when using this release when the gate/door is open. Weak or 
broken springs may cause the gate/door to fall rapidly, causing 
severe INJURY or DEATH. 

•   KEEP GATES/DOORS PROPERLY OPERATING AND BALANCED. 

Read the gate/door manufacturer's owner’s manual. An improperly 
operating or balanced gate/door could cause severe INJURY or 
DEATH. Have a qualified service person make repairs to gate/door 
hardware. Have trained gate/door systems technician make repairs 
to cables, spring assemblies, and other hardware.

•   The entrance is for vehicles ONLY. Pedestrians MUST use separate 

entrance.

•   SAVE THESE INSTRUCTIONS.

USAGE CLASS

IMPORTANT SAFETY INFORMATION

CLASS I – RESIDENTIAL VEHICULAR GATE 
OPERATOR

A vehicular gate operator (or system) intended for use in garages or 
parking areas associated with a residence of one-to four single families.

CLASS II – COMMERCIAL/GENERAL ACCESS 
VEHICULAR GATE OPERATOR

A vehicular gate operator (or system) intended for use in a commercial 
location or building such as a multi-family housing unit (five or more 
single family units), hotel, garages, retail store, or other buildings 
accessible by or servicing the general public.

CLASS III – INDUSTRIAL/LIMITED ACCESS 
VEHICULAR GATE OPERATOR

A vehicular gate operator (or system) intended for use in an industrial 
location or building such as a factory or loading dock area or other 
locations not accessible by or intended to service the general public.

CLASS IV– RESTRICTED ACCESS VEHICULAR GATE 
OPERATOR

A vehicular gate operator (or system) intended for use in a guarded 
industrial location or building such as an airport security area or other 
restricted access locations not servicing the general public, in which 
unauthorized access is prevented via supervision by security personnel.

Summary of Contents for HCTDCU

Page 1: ... 8 feet 2 4 m above the floor This model is intended for use in Class II III and IV vehicular trolley gate or commercial door applications Visit LiftMaster com to locate a professional installing dealer in your area This gate door operator is compatible with MyQ and Security 2 0 accessories Register your operator to receive updates and offers from LiftMaster Take a photo of the camera icon includi...

Page 2: ...ORMATION 4 GATE CONSTRUCTION INFORMATION 5 INTRODUCTION 6 CARTON INVENTORY 6 OPERATOR SPECIFICATIONS 7 OVERVIEW OF TYPICAL INSTALLATION 8 INSTALLATION 9 IMPORTANT SAFETY INFORMATION 9 CONNECT RAIL TO OPERATOR 10 INSTALL VENTED PLUG 11 DETERMINE LOCATION FOR OPERATOR 11 MOUNT THE OPERATOR 12 INSTALL ENTRAPMENT PROTECTION 13 WIRING 15 POWER WIRING 15 CONNECT BATTERIES 16 ADJUSTMENT 17 LIMIT AND FORC...

Page 3: ...on when using this release when the gate door is open Weak or broken springs may cause the gate door to fall rapidly causing severe INJURY or DEATH KEEP GATES DOORS PROPERLY OPERATING AND BALANCED Read the gate door manufacturer s owner s manual An improperly operating or balanced gate door could cause severe INJURY or DEATH Have a qualified service person make repairs to gate door hardware Have t...

Page 4: ... under around or through the gate to operate the controls Outdoor or easily accessible controls shall have a security feature to prevent unauthorized use Exception Emergency access controls only accessible by authorized personnel e g fire police may be placed at any location in the line of sight of the gate 9 The Stop and or Reset if provided separately must be located in the line of sight of the ...

Page 5: ...NFORMATION Vehicular gates should be installed in accordance with ASTM F2200 Standard Specification for Automated Vehicular Gate Construction For a copy contact ASTM directly at 610 832 9585 or www astm org 3 1 4 A positive stop shall be required to limit travel to the designed fully open position 3 2 Class IV vehicular vertical lift gates shall be designed constructed and installed in accordance ...

Page 6: ...VENTORY NOT SHOWN Documentation Packet HCTDCU Motor Unit 8 Foot 2 4 m Rail HCT08 10 Foot 3 1 m Rail HCT10 12 Foot 3 7 m Rail HCT12 Battery 12 Vdc 7AH 2 Warning Signs 2 and Warranty Card LiftMaster Photoelectric Sensors CPSUN4G ...

Page 7: ...erator length 10 foot 3 1 m gate 13 75 foot 4 2 m operator length 12 foot 3 7 m gate 15 75 foot 4 8 m operator length Maximum Gate Door Weight 700 lbs 317 5 kg Maximum Gate Door Width sectional and one piece 22 ft 6 7 m Travel Speed Default 8 inches 20 3 cm per second Fast 11 inches 27 9 cm per second open speed only Maximum Daily Cycle Rate Continuous Maximum Duty Cycle Continuous Operating Tempe...

Page 8: ...or obstruction exists at either the opening or closing direction Care shall be exercised to reduce the risk of nuisance tripping such as when a vehicle trips the sensor while the gate door is still moving Make sure the door opens and closes smoothly Door should stay in the open position when springs are properly balanced Make sure the gate opens and closes smoothly Gate should stay in the open pos...

Page 9: ...through the openings anywhere in the gate door 8 Entrapment protection devices MUST be installed to protect anyone who may come near a moving gate door Upon completion of installation test entrapment protection device 9 Too much force on gate door will interfere with proper operation of safety reversal system NEVER increase force beyond minimum amount required to move gate door NEVER use force adj...

Page 10: ...Tighten cap screws on key holes 5 Cut the cable tie on the chain and position the trolley within 3 feet 9 m of the end of the rail 6 Wrap the chain around the sprocket 7 Adjust the chain tension with the turnbuckle so that the chain hangs no more than 1 4 64 cm from the top of the rail Tighten the hex nut to secure the chain 8 Reattach the chain guard to the chassis 9 Close the cover and attach wi...

Page 11: ... mark the center point on the ceiling STEP 2 INSTALL VENTED PLUG 1 Remove the dome plug from the operator chassis 2 Remove the solid plug in the gear reducer and replace it with the vented plug provided in bag with manual 3 Tighten the vented plug with a socket or Allen wrench 4 Re insert the dome plug Vented Plug Dome Plug ...

Page 12: ...ader bracket is in the center of the opening Bolt or weld the header bracket to the wall 2 Lift the operator and align with center mark on ceiling Have someone hold the operator in place or use a post as a temporary support Bolt the operator to the ceiling A support post is not part of the operator Use only for installation 3 Bolt or weld arm to gate door Door Arm Arm Brackets not provided Flush M...

Reviews: