13
Invisible Light Beam
Protection Area
Sensor
Sensor
Safety Reversing Sensor
Bell Wire
Bell Wire
Motor unit
Safety Reversing Sensor
Power Door Lock
Quick-Connect Terminals
WHT/BLK
WHT
Sensor
Connections
To Power
Door Lock
To CableTension Monitor
To Door Control
dry contact
Connect Wire to
Quick-Connect
Terminals
com
no
MAX height
150mm (6”)
MIN height
50mm (2”)
MOUNTING AND WIRING THE SAFETY
REVERSING SENSORS
•
Run the wires from both safety reversing sensors to the
operator. Use insulated staples to secure wire to wall
and ceiling.
• Strip 11mm (7/16") of insulation from each set of wires.
Separate white and white/black wires sufficiently to
connect to the operator quick-connect terminals: white to
white and white/black to grey (Figure 6).
TROUBLESHOOTING THE SAFETY
REVERSING SENSORS
1. If the
sending eye indicator LEDs are both blinking
after installation, check for:
• Electric power to the operator.
• A short in the white or white/black wires. These can
occur at staples, or at operator connections.
• Incorrect wiring between safety reversing sensors and
operator.
• A broken wire.
2. If the sending eye indicator light
glows steadily but the
receiving eye indicator light doesn't:
• Check alignment.
• Check for an open wire to the
receiving eye.
3. If the
receiving eye indicator light is dim, realign
either sensor.
NOTE:
When the invisible beam path is obstructed or
misaligned while the door is closing, the door will reverse.
If the door is already open, it will not close.
and 10 clicks will sound.) See page 19.