10
INSTALLATION STEP 5
Electrical Requirements
To avoid installation difficulties, do not run the
operator at this time.
To reduce the risk of electric shock, your door operator
has a grounding type plug with a third grounding pin. This
plug will only fit into a grounding type outlet. If the plug
doesn't fit into the outlet you have, contact a qualified
electrician to install the proper outlet.
RIGHT
WRONG
To prevent possible SERIOUS INJURY or DEATH from
electrocution or fire:
• Be sure power is not connected to the operator, and
disconnect power to circuit BEFORE removing cover.
• Door installation and wiring MUST be in compliance
with ALL local electrical and building codes.
• NEVER use an extension cord, 2-wire adapter or
change plug in any way to make it fit outlet. Be sure
the operator is grounded.
• If the supply cord is damaged, it must be replaced by
the manufacturer or itʼs service agent or a similiarly
qualified person in order to avoid harzard.
+
+
GRIFCO
Mount the wireless wall control out of the
reach of children at 1.5m
INSTALLATION STEP 6
Installing the Wireless Wall control (CG128)
Control must be mounted out of the reach of children
at a height of 1.5m with an unobstructed view of the
door.
• Ensure you CG3800 operator is switched off whilst
installing your wireless door control to prevent accidental
activation
• Remove the cover from the CG128.
• Mount CG128 as shown using the screws provided if
mounting into a wall box (not provided).
• If mounting directly on the wall use wall anchors
(provided) to fix unit to the plasterboard wall.
• Replace the cover plate and
affix the warning label
adjacent the wall controller.
Fix the emergency door release label adjacent to the
operator.
To reduce risk of fire, explosion or chemical burn:
• Replace ONLY CR2032 batteries.
• Do NOT recharge, disassemble, heat above 75°C or
incinerate.