Models EV1020, EV1220, EV1520
Installation, Operation and Maintenance
Rev.12/16/2020
EV-IOM-A.doc
11
T9
T5
T4
T6
M
T8
T3
T7
T2
T1
1
2
3
4
5
6
FACTORY WIRED FOR
208−240V
6
4
2
5
3
1
RECONNECTIONS FOR
440−480V
T3
T2
T1
T9
T6
T7
T4
T8
T5
FOR THREE PHASE
M
1
5
4
6
(Normally Open)
M
FIELD
CONECTIONS
Wiring Diagram
FOR SINGLE PHASE
Fig. 7