Linak DESKLINE DL18 IC User Manual Download Page 1

Page 1 of 24

LINAK.COM

/DESKLINE

DL18 IC/DL19 IC system  

User manual

Summary of Contents for DESKLINE DL18 IC

Page 1: ...Page 1 of 24 LINAK COM DESKLINE DL18 IC DL19 IC system User manual ...

Page 2: ...completed machinery 8 Declaration of Conformity 9 Misc on the DESKLINE DL18 IC DL19 IC system 12 Warranty 12 Maintenance 12 ETL marking 13 Description of the DESKLINE DL18 IC DL19 IC system 15 Mounting guidelines for the DESKLINE DL18 IC DL19 IC system 15 Mount the motor housing 15 Mounting the feet 16 Mounting crossbar 17 Mounting the tabletop 17 Placing the monitor 17 Connection 19 Accessories a...

Page 3: ...ctory they undergo full function and quality testing Should you nevertheless experience problems with your LINAK product system you are always welcome to contact your local contact LINAK subsidiaries and some distributors situated all over the world have authorised service centres which are always ready to help you LINAK provides a warranty on all its products This warranty however is subject to c...

Page 4: ... for This User Manual is valid for the following products See the first 3 5 characters on the label Columns 2 lifting columns DL18 IC DL19 IC Power supply SMPS001 SMPS002 or SMPS006 Controls DPA DPB DPH DP1K DPF1K DPG1K ...

Page 5: ... or one of its components It is important for everyone who is to connect install or use the systems to have the necessary information and access to this User Manual Follow the instructions for mounting there is a risk of injury if these instructions are not followed The appliance is not intended for use by young children or infirm persons without supervision If there is visible damage to the produ...

Page 6: ...e builder of the equipment shall ensure that the use of the component complies with relevant standards like the Machine Directive Care must be taken to avoid squeezing of cables as it can cause movement of the system The SMPS001 SMPS002 SMPS006 must not be packed in heat insulating material but must be placed so that it can emit waste heat to the surroundings There are no ventilation holes to cons...

Page 7: ... connection The individual parts must be connected before connecting the control box to the mains See the User Manual for LINAK actuators if necessary During operation If the column makes unusual noise or smells switch off the mains voltage immediately Take care that the cables are not damaged Unplug the mains cable on mobile equipment before moving it The products must only be used in an environm...

Page 8: ...ns with reduced physical sensory or mental abilities must not use the product products unless they are under surveillance or they have been thoroughly instructed in the use of the apparatus by a person who is responsible for the safety of these persons Moreover children must be under surveillance to ensure that they do not play with the product It is the operator s responsibility to ensure that th...

Page 9: ...14 DL15 DL16 DL17 DL19 BASE1 Desk Panels DPA DPB DPH DPF DPG1K DPG1M DPG1B DPG1C DPT DP1 DP1CS DP1K DP1V DP1U RF Controls HB10RF HB20RF RFT RFRL Accessories BA001 SLS Kick Click comply with the following parts of the Machinery Directive 2006 42 EC ANNEX I Essential health and safety requirements relating to the design and construction of machinery 1 5 1 Electricity supply The relevant technical do...

Page 10: ... EN 61000 6 3 2007 EN 55022 2010 Class B complies with Low Voltage Directive 2006 95 EC according to the standards EN 60335 1 2012 complies with RoHS2 Directive 2011 65 EU according to the standard EN 50581 2012 And RF Control RFRL00x HB1xRF3000 HB2xRFx000 RFT000 complies with the Radio Equipment Directive 2014 53 EU EN 300220 2 2006 EN 61000 6 1 2007 EN 61000 6 3 2007 EN 60335 1 2012 EN 62311 200...

Page 11: ...omplies with the EMC Directive 2014 30 EU according to following standards EN 61000 6 1 2007 EN 61000 6 3 2007 complies with Low Voltage Directive 2014 35 EU according to the standard EN 61558 2 16 2009 complies with RoHS2 Directive 2011 65 EU according to the standard EN 50581 2012 This declaration of conformity is issued under the sole responsibility of the manufacturer ...

Page 12: ...m for damage and breaks Inspect the connections cables and plugs and check for correct functioning as well as fixing points Service of double insulated products Class II A Class II or double insulated electrical appliance is one which has been designed in such a way that it does not require a safety electric earth connection US ground The basic requirement is that no single failure can result in d...

Page 13: ...o CSA Std C22 2 No 68 09 ETL Recognized Component mark for Canada and United States C N 4009507 Conforms to UL962 Cert to CSA Std C22 2 No 68 09 ETL Recognized Component mark for Canada and United States ETL marking Due to space limitations the complete ETL marking demands are not represented on the marking plates The full ETL Recognized Component markings are shown here C N 120690 Conforms to UL9...

Page 14: ...pause stated in the data sheets must NOT be exceeded as this will result in a superheating of the motor the brake and the spindle nut Exceeding the duty cycle will result in a dramatic reduction of the service life of the system A typically DL IC system consists of 2 lifting columns DL18 IC DL19 IC Master and Follower Power supply SMPS001 SMPS002 or SMPS006 Desk panel DPA DPB DPH DP1K DPF1K or DPG...

Page 15: ...M top frame and avoid screws to get easy desk assembly Installation Mounting guidelines for the DESKLINE DL18 IC DL19 IC system The motor housing is supplied with six M6 threaded holes for mounting on the top frame 1 Mount motor housing on top frame using six M6 screws with the following specifications Quality Min grade 8 8 Length Max 10 mm plus top frame thickness The bolt must not go further tha...

Page 16: ... 16 mm plus foot thickness for M6 Max 14 mm plus foot thickness for M8 2 Fasten screws thoroughly torque max 10 Nm The holes in the foot must be sufficiently larger than ø6 ø8 to ensure space for the screw heads to be screwed fully into the foot Drawing No SAMLET_SKRUE_BILLED Drawing No SAMLET_SKRUE_BILLED Min 10 mm Max 14 mm Min 10 mm Max 16 mm M8 M6 Min 10 mm Max 14 mm Min 10 mm Max 16 mm M8 M6 ...

Page 17: ...ke sure that you do not pull the bracket off the column when tightening the screws for the assembly The maximum torque for tightening the 2 x M8 screws in the bracket is 15 Nm To avoid damage to the lifting column there must be at least 1 mm space between the ends of the two M8 screws for the mounting bracket and the lifting column surface Screws that are too long will come into contact with the i...

Page 18: ...e monitor Placement of a monitor directly above the motor housing may cause malfunction of the monitor Magnets inside the motor may interrupt the picture on the monitor depending on distance and type of monitor If this is the case the problem may be solved by placing an iron plate tube or another magnetic material somewhat larger than the motor housing between the motor and the tabletop Recommende...

Page 19: ...ed Motor cable Desk panel example SMPS cable 1 Connect the master and follower columns using the motor cable 2 Mount the desk panel onto the desk and connect it to the master column 3 Connect the SMPS to the master column and to the mains ...

Page 20: ...utor or subsidiary Repairs Systems should only be repaired by an authorised LINAK service centre or engineer Systems to be repaired under warranty must be sent to an authorised LINAK service centre Warning By unauthorised opening of the system there is a risk that it may malfunction at a later date Spare parts Please contact your nearest LINAK contact for information on spare parts ...

Page 21: ...stic recycling or combustion Cable scrap or combustion Metal scrap Handset Control Plastic housing Cable PCB board Plastic recycling or combustion Cable scrap or combustion Electronics scrap By now almost all our casted plastic parts are supplied with an interior code for plastic type and fibre content if any Disposal of batteries Details regarding safe disposal of used and leaking batteries Batte...

Page 22: ...Page 22 of 24 Label for DL19 IC Master Labels Label for DL19 IC Follower Label for SMPS001 Label for SMPS002 Label for SMPS006 Label for DL18 IC Master Label for DL18 IC Follower ...

Page 23: ... IC Version Combination code B Built in length mm S Stroke length mm O Outer profile length mm EU DL18xxxxxx500645 645 500 590 DL18 built in length stroke length and outer profile length mm DL18 IC motor housing and profile dimensions mm ...

Page 24: ...Page 24 of 24 DL18 IC Bracket options DL18 motor housing and profile dimensions mm Combination code Bench left Bench right DL18xxLxxSxxxxxx X DL18xxRxxMxxxxxx X Bracket options dimensions in mm ...

Page 25: ...on Combination code B Built in length mm S Stroke length mm O Outer profile length mm EU DL19xxxxxx650560 560 650 498 DL19 built in length stroke length and outer profile length mm DL19 IC motor housing and profile dimensions mm ...

Page 26: ...Page 26 of 24 DL19IC Bracket options DL19 motor housing and profile dimensions mm Combination code Bench left Bench right DL19xxLxxSxxxxxx X DL19xxRxxMxxxxxx X Bracket options dimensions in mm ...

Page 27: ...Page 27 of 24 Sockets IC Master IC Follower Combination code Type DL19xxxxxMxxxxxx IC Master DL19xxxxxSxxxxxx IC Follower Profile designs Standard PLUS ...

Page 28: ...Page 28 of 24 SMPS001 SMPS002 ...

Page 29: ...Page 29 of 24 SMPS006 ...

Page 30: ...nder which LINAK products will be installed used and operated as each individual application is unique The suitability and functionality of the LINAK product and its performance under varying conditions application vibration load humidity temperature frequency etc can only be verified by testing and shall ultimately be the responsibility of the LINAK customer using any LINAK product LINAK shall be...

Page 31: ...ALIA S r l Phone 39 02 48 46 33 66 Fax 39 02 48 46 82 52 www linak it Japan LINAK K K Phone 81 45 533 0802 Fax 81 45 533 0803 www linak jp Malaysia LINAK Actuators Sdn Bhd Phone 60 4 210 6500 Fax 60 4 226 8901 www linak my Netherlands LINAK Actuator Systems B V Phone 31 76 5 42 44 40 www linak nl New Zealand LINAK New Zealand Ltd Phone 64 9580 2071 Fax 64 9580 2072 www linak com au Norway LINAK No...