8

20000706

NOTE: The BFC36 fireplace should be operated only 

with the doors closed.

MD706-7

Glass Door Position

1/20/99

BR, BC, BCMH, TF, TL, SHR, ODSHR

TSH, SR, ODSR, SC and WMC SERIES

STR, TST, and CVR SERIES

BFC36

CR SERIES 

RIGHT

RIGHT

RIGHT

WRONG

CLOSED

OPEN

CLOSED

OPEN

CLOSED

OPEN

CLOSED

EWF36

CLOSED

OPEN

Optional Spark Screen

RIGHT

WRONG

CLOSED

OPEN

Optional Spark Screen

EWF30

  

6. Operating Glass Door
WARNING: Use only glass doors approved by CFM 
Corporation for use with your particular fireplace.

If your fireplace is equipped with glass doors, start the 
fire and leave the doors fully open. AFTER the fire is 
well started, then the doors may be closed. We rec-
ommend for the most efficient use of glass doors on 
all models of CFM Corporation fireplaces, except for 
models BFC, EWF and WMC Series, that doors must 
be fully open when firing at a ‘moderate’ to ‘hot’ rate. 
Firing at a ‘low’ to ‘moderate’ rate or allowing fire to die 
out, doors should be closed. The BFC, EWF and WMC 
Series fireplaces are designed for maximum heat out-
put with doors fully closed at all times.

NOTE: 

The BFC fireplace should be operated only with 

the doors fully closed.

NOTE:

 The EWF fireplace should be operated only 

with the doors fully closed or fully open only when the 
optional spark screen is installed.

WARNING: FIREPLACES EQUIPPED WITH DOORS 
SHOULD BE OPERATED WITH DOORS FULLY 
OPEN OR DOORS FULLY CLOSED. IF DOORS ARE 
LEFT PARTLY OPEN, GAS AND FLAME MAY BE 
DRAWN OUT OF THE FIREPLACE OPENING CRE-
ATING RISKS OF BOTH FIRE AND SMOKE. Refer to 
Figure 9 for correct door positions.

Do not close the glass doors on an excessively hot fire. 
This could remove the temper from the glass, causing 
it to crack into small pieces. The glass must be allowed 
to warm slowly. The tempered glass in the doors will 
withstand a gradual temperature rise to 550° F, which 
is more than a normal fire will create. An excessively 
hot fire can be created by such things as pitch laden 
logs, very dry mill end lumber or large amounts of paper 
or cardboard cartons. Keep the fire well back from the 
doors and never let flames contact the glass.
Breakage may occur if the glass doors are mishandled. 
Always use caution when operating the doors and do 
not slam or force them into position.

To vary the burn rate, adjust the control to the desired 
position in between these extremes; opening the 
primary air control makes the unit burn hotter. Closing 
the control slows the unit down. You may adjust to any 
position you desire.

Fig. 9 

  Top view of glass door operation.    

 

MD706-7

Summary of Contents for TF Series

Page 1: ...oyer à bois BC BCMH BFC BR CR CVR EWF ODSHR ODSR SC SHR SR STR TF TL TSH TST and WMC Series Fireplaces Save This Homeowner s Manual Conservez ce manuel du propriétaire 20000706 2 07 Rev 11 FOYERS SÉRIES BC BCMH BFC BR CR CVR EWF ODSHR ODSR SC SHR SR STR TF TL TSH TST et WMC ...

Page 2: ...tions 9 Maintenance and Care of Fireplace 10 Troubleshooting Guide 11 Accessories 13 Table of Contents Table des Matières Faites connaissance avec votre foyer 16 Mode d emploi de votre foyer 18 Mesures de précaution 23 Entretien et soins du foyer 24 Guide de dépannage 25 Accessoires 27 ...

Page 3: ...t to CFM Corporation In order to validate your warranty it is mandatory that you write the serialization number a series of letters and numbers located below the model number on the warranty card The serial number is stamped into the black plate attached to the inner dome side of the firebox For better understanding of your fireplace familiarize yourself with the following parts and terminologies us...

Page 4: ...our fireplace is equipped with outside air the control lever will be located at the front edge of the left side brick on the BR TF SR ODSR WMC STR and TST Series On the CR Series fireplaces it is located at the lower left or right corner of the air inlet On the SHR ODSHR and TSH Series the control lever is located in the center just above the left side brick Refer to Page 6 for proper operation proc...

Page 5: ...ation is obtained in the least open position When refueling fully open damper before opening glass doors BR BC BCMH TF TL CR SR ODSR and SC Se ries Damper The flue damper is located in the dome area in the middle of the firebox The damper is opened by rotating the lever to the right The damper is closed by pushing the lever to the left and is locked closed by the damper clip located on the dome The ...

Page 6: ...top of the other two forming a crude pyramid Be sure the irregularities of the logs form air spaces between the logs Fig 6 If they do not place a few sticks of kindling between the logs to separate them slightly Additional logs may be added as needed to maintain heat output Logs should be split preferably in quarter sections or smaller pieces Split logs have more burn ing surfaces than whole logs ...

Page 7: ...be drawn into the firebox and expelled up the flue NOTE Never use gasoline gasoline type lantern fuel kerosene charcoal lighter fluid or similar liquids to start or freshen up a fire in this fireplace while it is in use 4 Open Outside Air Damper Your fireplace may be equipped with outside combus tion air To determine refer to Outside Combustion Air on Page 3 If your fireplace has outside air the air damp...

Page 8: ...ace should be operated only with the doors fully closed or fully open only when the optional spark screen is installed WARNING FIREPLACES EQUIPPED WITH DOORS SHOULD BE OPERATED WITH DOORS FULLY OPEN OR DOORS FULLY CLOSED IF DOORS ARE LEFT PARTLY OPEN GAS AND FLAME MAY BE DRAWN OUT OF THE FIREPLACE OPENING CRE ATING RISKS OF BOTH FIRE AND SMOKE Refer to Figure 9 for correct door positions Do not cl...

Page 9: ...y 11 Operation of BFC36 Clean Burning Fireplace The BFC36 fireplaces have been designed specifically to reduce smoke and hydrocarbon emissions however the performance of these fireplaces depends on proper operation In order to reduce emissions use only well seasoned firewood Avoid slow burning smoldering fires and maintain a hot coal bed on which to place new wood High firebox temeratures help to ensure...

Page 10: ...ep the bottom air inlet channel free of obstructions 7 To prevent discoloration on brass finished doors check finish for a protective plastic coating and re move if applicable 8 Do not use abrasive cleaners on glass doors 9 Do not clean while hot Maintenance and Care of Your Fireplace Your fireplace is built to operate trouble free with little need for extensive time consuming maintenance As with any...

Page 11: ... the complete fireplace Replacement Parts Replacement parts for your fireplace can be obtained from your CFM Corporation Dealer For information on replacement parts that are available refer to installation and homeowner s manual provided with each accessory Should you need additional information beyond what your dealer can furnish contact CFM Corporation 410 Admiral Blvd Mississauga Ontario Canada L...

Page 12: ...ing procedure Cold Air Present at Fireplace and Surround Facing If noncombustible materials brick stone marble tile etc are used to finish fireplace face inspect area between fireplace and facing material for gaps If gaps appear area must be sealed with a noncombustible ma terial to prevent cold air from entering the room Intermittent Cold Air Problems If your home is tightly sealed and well insulate...

Page 13: ...8 or S 8 3041130 42GDKBKSR 42GDKDPSR 42GDKSSR SR42A AK MST N A 42GDKBBSR SK8 or S 8 3041130 42GDKBKSR 42GDKDPSR 42GDKSSR ODSR42A AKU1 N A 42GDKBBSR SK8 or S 8 20002230 42GDKBKSR 42GDKDBSR 42GDKSSR 42GDKSSSR STR33 AK MST N A 33GDKBB SK8 only 8 2056100 33GDKBK 33GDKDP 33GDKS STR36 CVR36 AK MST N A 36GDKBB SK8 only 8 2056100 36GDKBK 36GDKDP 36GDKS Woodburning Models Accessories for Woodburning Firepl...

Page 14: ...STD STD S only 8 RSBG36 CR36L CR36R AK MST N A 36GCKBB SK8 only 8 RBGC36L or R BFC36 AK MST FKSX A STD S only 8 RBGBFC36 EWF36A AK MST FK26 STD S only 13 N A EWF30 AK MST FK26 STD SK or S 8 or 13 N A Accessories for Woodburning Fireplaces continued Woodburning Models Outside Air Fan Kit Glass Door Kit Chimney System1 Flue Dia Basket Grate 1 SK 2 WALL SYSTEM W 11 O D CF 2 WALL SYSTEM W 13 1 2 O D S...

Page 15: ...20000706 15 Beaucoup de plaisir avec votre foyer à bois FOYERS SÉRIES BC BCMH BFC BR CR CVR EWF ODSHR ODSR SC SHR SR STR TF TL TSH TST et WMC ...

Page 16: ...vert par cette dernière Remplissez la carte de garantie et postez la à CFM Home Products Pour valider votre garantie vous devez inscrire sur la carte de garantie le numéro de sérialisation série de lettres et de chiffres située sous le numéro de modèle Le numéro de série est estampé sur la plaque noire fixée sur la voûte interne du foyer Pour mieux comprendre votre foyer familiarisez vous avec les ...

Page 17: ...entrer dans ce processus de remplacement naturel Pour maintenir un débit constant d air de combustion il faut de l air extérieur direct Les foyers CFM Corporation sont conçus pour que de l air extérieur puisse alimenter directement la chambre de combustion en air de combustion Le circuit d air nécessite la pose d un conduit allant du foyer à une source d air extérieur lors de l installation initia...

Page 18: ...ubliez pas le registre doit tou jours être complètement ouvert lorsqu il y a un feu Registre WMC Le registre du conduit s ouvre et se ferme grâce à un bouton se trouvant juste en dessous de la grille de sortie du dessus Fig 1 Le registre est réglable et peut être ouvert partiellement du moment que les portes vitrées sont fermées et que la fumée n apparaisse pas dans l aire de combustion Le ren dem...

Page 19: ...er avec grille Prépa rer le feu directement sur la grille Ne soulevez pas le bois Mettez une bonne quantité de papier journal froissé ou tordu sur l âtre sous la grille Laissez dépasser quelques bouts de papier de la zone des bûches pour pouvoir les allumer Disposez sur le papier du bois d allumage bouts de bois de faible diamètre en les croisant Mettez une bûche de grand diamètre sur le bois d al...

Page 20: ...i ci ou des grilles de refoulement de circulation de chaleur Cela est dû à la cuisson de la peinture et à la combustion de l huile recouvrant le métal C est normal et disparaît après les premiers feux Si votre foyer est muni de portes en verre et d un conduit d air extérieur ouvrez les portes et fermez l arrivée d air extérieur Les odeurs et la fumée doivent être attirées dans la chambre de combus...

Page 21: ...n sauf les modèles de série BFC EWF et WMC pour lesquels les portes doivent être complètement ouvertes pour un feu modéré Fermé Ouvert à chaud Pour un feu faible à modéré ou pour l extinction du feu les portes doivent être fermées Les foyers de série BFC EWF et WMC sont conçus pour une chaleur maximum avec les portes complètement fermées en permanence NOTE Le foyer BFC doit fonctionner uniquement ...

Page 22: ...en ajoutant des bûches supplémentaires au besoin Utilisez un tisonnier pour rassembler les bûches en combustion en un groupe serré à l arrière du foyer chaque fois que vous ajoutez de nouvelles bûches Maintenez le lit de braise directement sous les bûches Cela aide à maintenir le feu mais ne laissez pas les cendres trop s accumuler jusqu à nuire à une circulation d air adéquate à travers les bûche...

Page 23: ...eut aussi réduire le tirage La fermeture trop rapide du registre peut arrêter le feu ou désactiver la chambre de combustion Fermez le registre uniquement quand le feu est bien allumé Pour allumer un feu attendez qu il y ait une couche de braise d au moins 3 4 pouces avant de fermer le registre 13 Fonctionnement du EWF30 Le foyer EWF3O répond aux normes d émission établies par la US Environmental P...

Page 24: ...rer Lorsque le bois brûle lentement il produit du goudron des vapeurs organiques et de l humidité qui se com binent pour former de la créosote Les vapeurs de créosote se condensent dans un conduit de cheminée relativement froid d une combustion lente En consé quence le résidu de créosote s accumule sur le doubla ge de cheminée Lorsque cette créosote s enflamme la combustion produit une chaleur inte...

Page 25: ... et fabriqué pour fonctionner sans défaillance En raison de l atmosphère de l environnement résidentiel et de techniques d utilisation inappropriées vous pouvez rencontrer les anomalies suivantes auxquelles vous pouvez remédier vous même Si l anomalie ne peut pas être corrigée communiquez avec votre détaillant CFM Corporation local pour qu il vous aide Problèmes de fumée Il y a de la fumée à l all...

Page 26: ...froid En cas d absence d isolation communiquez avec votre détaillant CFM Corporation pour connaître les bonnes méthodes d isolation Air froid au foyer et au parement de l habillage Si des matériaux incombustibles brique pierre mar bre tuile etc sont utilisés pour finir l avant du foyer vérifiez s il y a un espace dans la zone entre le foyer et le matériau du parement S il y a des espaces la zone doi...

Page 27: ...t CFM Corporation Pour toute information sup plémentaire qui dépasse ce que votre détaillant peut vous fournir communiquez avec CFM Corporation 410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 ATT Service à la clientèle Modèles à Bois Air extÉrieur Nécessaire de ventilateur Nécessaire de porte en verre Système de cheminée Dia Du con duit Grille BC36 BC36i AK MST FK12 36GDKBB SK8 or S 8 po 30301...

Page 28: ...0005762 52SHGDKBK seulement 52SHGDKDP 52SHGDKS WMC36 STD STD STD S SK8 8 RSBG36 WMC42 STD STD STD S 8 RSBG36 CR36L CR36R AK MST S O 36GCKBB SK8 seulement 8 RBGC36L or R BFC36 AK MST FKSX A STD S seulement 8 po RBGBFC36 EWF36 AK MST FK26 STD S seulement 13 po S O EWF30 AK MST FK26 STD SK or S 8 ou 13 po S O Modèles à bois Air extérieur Nécessaire de ventilateur Nécessaire de porte en verre Système ...

Reviews: