![Ceyear 1465 Series Programming Manual Download Page 112](http://html1.mh-extra.com/html/ceyear/1465-series/1465-series_programming-manual_2584913112.webp)
3 SCPI
3.3 Instrument subsystem command
105
RESet. For setting Trig Mode, see the command ―
:RADio:ARB:TRIGger:TYPE
‖.
Setting format:
[:SOURce]:RADio:ARB:TRIGger:TYPE:SINGle
FREE|TRIGger|RESet
Query format:
[:SOURce]:RADio:ARB:TRIGger:TYPE:SINGle?
Parameter:
<Mode> Discrete data. The mode in which sequence file responds to trigger signal when ARB is in
Single mode,
The values are as follows:
FREE | 0: When Auto mode is selected, sequence is triggered automatically to start
playing after sequence waveform data is downloaded. All trigger
events are ignored during playback
TRIGger | 1: When Trig mode is selected, no current waveform sequence will be
played until a valid trigger event is received. After a valid trigger
event is received, the system starts to play the current waveform
sequence. After the sequence is played, no current waveform
sequence is replayed until a valid trigger event occurs
RESet | 2: When Realtime mode is selected, no modulation source data will be
generated until a valid trigger event is received, with no code
pattern signal generated; after a valid trigger event is received,
the system starts to generate the selected modulation source
data, thereby generating corresponding code pattern data and
signals. After the current source data is generated, the system
will automatically restart to generate the currently set modulation
source data. During the generation process of modulation source
data, if a valid trigger event is received, the system will
immediately abort the modulation source data currently being
generated and restart to generate the set modulation source
data
Example:
[:SOURce]:RADio:ARB:TRIGger:TYPE:SINGle TRIG
When ARB is in Single mode, set the mode in which sequence file responds to trigger signal to Trig.
Reset status:
FREE
Key Entry:
【
Arb
】
—>[Trigger]—>[Trig Mode]—>[Single]
[:SOURce]:RADio:ARB:TRIGger:TYPE:SADVance[:TYPE] <Mode>
Function:
This command sets the mode in which sequence file responses to trigger signal when
ARB is in Wave Segment mode. There are two modes for selection, Single and
Continue. Wave segment play trigger function is not for the entire waveform sequence,
but a single wave segment in the sequence. For setting Trig Mode, see the command
―
:RADio:ARB:TRIGger:TYPE
‖.
Setting format:
[:SOURce]:RADio:ARB:TRIGger:TYPE:SADVance:TYPE
SINGle|CONTinuous
Query format:
[:SOURce]:RADio:ARB:TRIGger:TYPE:SADVance:TYPE?
Summary of Contents for 1465 Series