5

ELECTRIC SHOCK can kill.

5.a. The  electrode  and  work  (or  ground)

circuits are electrically “hot” when the
welder is on. Do not touch these “hot”
parts with your bare skin or wet cloth-
ing.  Wear  dry,  hole-free  gloves  to
insulate hands.

5.b. Insulate  yourself  from  work  and  ground  using  dry

insulation. Make certain the insulation is large enough
to  cover  your  full  area  of  physical  contact  with  work
and ground.

In  addition  to  the  normal  safety  precautions,  if
welding  must  be  performed  under  electrically
hazardous conditions (in damp locations or while
wearing wet clothing; on metal structures such as
floors,  gratings  or  scaffolds;  when  in  cramped
positions  such  as  sitting,  kneeling  or  lying,  if
there  is  a  high  risk  of  unavoidable  or  accidental
contact with the workpiece or ground) use the fol-
lowing equipment:

• Semiautomatic  DC  Constant  Voltage  (Wire)

Welder.

• DC Manual (Stick) Welder.
• AC Welder with Reduced Voltage Control.

5.c. In semiautomatic or automatic wire welding, the elec-

trode,  electrode  reel,  welding  head,  nozzle  or  semi-
automatic welding gun are also electrically “hot”.

5.d. Always be sure the work cable makes a good electrical connection

with the metal being welded. The connection should be as close as
possible to the area being welded.

5.e. Ground the work or metal to be welded to a good electrical (earth)

ground.

5.f.

Maintain the electrode holder, work clamp, welding cable and weld-
ing machine in good, safe operating condition. Replace damaged
insulation.

5.g. Never dip the electrode in water for cooling.

5.h. Never  simultaneously  touch  electrically  “hot”  parts  of  electrode

holders  connected  to  two  welders  because  voltage  between  the
two can be the total of the open circuit voltage of both welders.

5.i.

When working above floor level, use a safety belt to protect your-
self from a fall should you get a shock.

5.j.

Also see Items 4.c. and 1.

El ELECTROCHOQUE
puede causar la muerte.

5.a. Los  circuitos  del  electrodo  y  pieza  de
trabajo (o tierra) están eléctricamente “vivos”
cuando  la  soldadora  está  encendida.  No

tocar esas piezas “vivas” con la piel desnuda o ropa mojada.
Usar guantes secos sin agujeros para aislar las manos.

5.b. Aislarse de la pieza de trabajo y tierra usando aislante

seco. Asegurarse que el aislante sea lo suficientemente
grande para cubrir toda el área de contacto físico con
la pieza de trabajo y el suelo.

Además de las medidas de seguridad normales, si es
necesario soldar en condiciones eléctricamente peli-
grosas (en lugares húmedos o mientras se está usan-
do  ropa  mojada;  en  las  estructuras  metálicas  tales
como suelos, emparrillados o andamios; estando en
posiciones apretujadas tales como sentado, arrodilla-
do o acostado, si existe un gran riesgo de que ocurra
contacto inevitable o accidental con la pieza de traba-
jo o tierra, usar el equipo siguiente:

• Soldadora (de alambre) de voltaje constante

CD semiautomática.

• Soldadora (de varilla) manual CD.
• Soldadora CA con control de voltaje reducido.

5.c.

En la soldadura con alambre semiautomática o automática, el elec-
trodo, carrete del electrodo, cabezal soldador, boquilla o pistola para
soldar semiautomática también están eléctricamente “vivas”.

5.d.

Siempre asegurar que el cable de trabajo tenga una buena conexión
eléctrica con el metal que se está soldando. La conexión debe ser lo
más cerca posible del área que se va a soldar.

5.e.

Conectar la pieza de trabajo o metal que se va a soldar a una buena
tierra eléctrica.

5.f.

Mantener el portaelectrodo, pinza de trabajo, cable de la soldadora y
la soldadora en condiciones de trabajo buenas y seguras. Cambiar el
aislante si está dañado.

5.g. Nunca sumergir el electrodo en agua para enfriarlo.

5.h.

Nunca tocar simultáneamente la piezas eléctricamente “vivas” de los
portaelectrodos conectados a dos soldadoras porque el voltaje entre
los dos puede ser el total del voltaje de circuito abierto de ambas sol-
dadoras.

5.i.

Cuando  se  trabaje  sobre  el  nivel  del  suelo,  usar  un  cinturón  de
seguridad para protegerse de una caída si llegara a ocurrir electro-
choque.

5.j.

Ver también las partidas 4.c. y 1.

LES  CHOCS  ÉLECTRIQUES
peuvent être mortels.

5.a.    Les  circuits  de  l'électrode  et  de  retour  (ou
masse)  sont  sous  tension  quand  la  source  de
courant est en marche.  Ne pas toucher ces pièces

sous tension les mains nues ou si l'on porte des vêtements mouillés.
Porter des gants isolants secs et ne comportant pas de trous.  

5.b.  S'isoler de la pièce et de la terre en utilisant un moyen d'isolation

sec.  S'assurer que l'isolation est de dimensions suffisantes pour
couvrir entièrement la zone de contact physique avec la pièce et
la terre.

En  plus  des  consignes  de  sécurité  normales,  si  l'on  doit
effectuer le soudage dans des conditions dangereuses au
point  de  vue  électrique  (dans  les  endroits  humides  ou  si
l'on  porte  des  vêtements  mouillés;  sur  les  constructions
métalliques  comme  les  sols,  les  grilles  ou  les
échafaudages;  dans  une  mauvaise  position  par  exemple
assis, à genoux ou couché, il y a un risque élevé de contact
inévitable ou accidentel avec la pièce ou la terre) utiliser le
matériel suivant :

• Source  de  courant  (fil)  à  tension  constante  c.c.  semi-

automatique.

• Source de courant (électrode enrobée) manuelle c.c.
• Source de courant c.a. à tension réduite.

5.c.  En soudage semi-automatique ou automatique, le fil, le dévidoir,

la  tête  de  soudage,  la  buse  ou  le  pistolet  de  soudage  semi-
automatique sont également sous tension.

5.d.  Toujours s'assurer que le câble de retour est bien connecté au

métal  soudé.    Le  point  de  connexion  devrait  être  le  plus  près
possible de la zone soudée.

5.e.  Raccorder la pièce ou le métal à souder à une bonne prise de

terre.

5.f.  Tenir  le  porte-électrode,  le  connecteur  de  pièce,  le  câble  de

soudage et l'appareil de soudage dans un bon état de fonction-
nement.  Remplacer l'isolation endommagée.

5.g.  Ne jamais tremper l'électrode dans l'eau pour la refroidir.

5.h.  Ne  jamais  toucher  simultanément  les  pièces  sous  tension  des

porte-électrodes  connectés  à  deux  sources  de  courant  de
soudage parce que la tension entre les deux peut correspondre
à la tension à vide totale des deux appareils.

5.i.  Quand on travaille au-dessus du niveau du sol, utiliser une cein-

ture  de  sécurité  pour  se  protéger  contre  les  chutes  en  cas  de
choc.

5.j.  Voir également les points 4.c. et 1.

MAR95

MAR95

MAR95

SAFETY

SEGURIDAD

SÉCURITÉ

Summary of Contents for Wire Feed 255

Page 1: ...S HABER LEIDO ESTE MANUAL Y LAS MEDIDAS DE SEGURIDAD QUE CONTIENE Y lo más importante piense antes de actuar y tenga mucho cuidado La sécurité dépend de vous Le matériel de soudage et de coupage à l arc Century est conçu et construit en tenant compte de la sécurité Toutefois la sécurité en général peut être accrue grâce à une bonne installation et à la plus grande prudence de votre part NE PAS INS...

Page 2: ... ENFANTS LES PERSONNES QUI PORTENT UN STIM ULATEUR CARDIAQUE DEVRAIENT CONSULTER LEUR MÉDECIN AVANT D UTILISER L APPAREIL Prendre connaissance des caractéristiques de sécurité suivantes Pour obtenir des renseignements supplémentaires sur la sécurité on recommande vivement d acheter un exemplaire de la norme Z49 1 de l ANSI auprès de l American Welding Society P O Box 351040 Miami Floride 33135 ou ...

Page 3: ...r al mínimo la exposición a los cam pos EMF del circuito de soldadura 3 d 1 Pasar los cables del electrodo y de trabajo jun tos Atarlos con cinta siempre que sea posible 3 d 2 Nunca enrollarse el cable del electrodo alrede dor del cuerpo 3 d 3 No colocar el cuerpo entre los cables del elec trodo y de trabajo Si el cable del electrodo está en el lado derecho el cable de trabajo también debe estar e...

Page 4: ... f Las chispas y salpicaduras son lanzadas por el arco de la soldadura Usar vestimenta protectora libre de aceite tales como guantes de cuero camisa gruesa pantalones sin bastillas zapatos de caña alta y un gorro Ponerse tapones en los oídos cuando se suelde fuera de posición o en lugares confinados Siempre usar gafas protectoras con escudos laterales cuando se esté en un área de soldadura 4 g Con...

Page 5: ...ezal soldador boquilla o pistola para soldar semiautomática también están eléctricamente vivas 5 d Siempre asegurar que el cable de trabajo tenga una buena conexión eléctrica con el metal que se está soldando La conexión debe ser lo más cerca posible del área que se va a soldar 5 e Conectar la pieza de trabajo o metal que se va a soldar a una buena tierra eléctrica 5 f Mantener el portaelectrodo p...

Page 6: ...asegurar que está dentro de los límites OSHA PEL y ACGIH TLV permisibles 6 c No soldar en lugares cerca de una fuente de vapores de hidrocarburos clorados provenientes de las operaciones de desengrase limpieza o pulverización El calor y los rayos del arco puede reaccionar con los vapores de solventes para formar fosgeno un gas altamente tóxico y otros productos irritantes 6 d Los gases protectores...

Page 7: ...ón utilizados Todas las mangueras rácores etc deben ser adecuados para la aplicación y estar en buenas condiciones 7 b Mantener siempre las botellas en posición vertical sujetas firmemente con una cadena a la parte inferior del carro o a un soporte fijo 7 c Las botellas de gas deben estar ubicadas Lejos de las áreas donde puedan ser golpeados o estén sujetos a daño físico A una distancia segura de...

Page 8: ...abajo 20 60 100 Amperes 255 Amps 150 Amps 120 Amps Voltios en Amperes Nominales 26 8 Volts 21 5 Volts 20 0 Volts Rango de corriente de soldadura Continuo 30 255 Amps Voltaje Máximo de Circuito Abierto 47 Volts Rango de Voltaje de Soldadura 15 5 26 8 Volts Corriente de Entrada a Salida Nominal de 150 Amp 24 2 Amps Corriente de Entrada a Salida Nominal de 255 Amp 56 Amps Voltaje de Entrada Frecuenci...

Page 9: ...aux ou autres applicables L interrupteur d alimentation de la WIRE FEED 255 doit être sur OFF arrêt quand on monte le câble de retour et le pistolet et quand on raccorde d autres équipements DÉBALLAGE DE LA WIRE FEED 255 Couper le cerclage et soulever le carton Couper le cerclage qui retient la machine à la palette Enlever la mousse et le matériau d emballage ondulé Détacher le ruban adhésif qui r...

Page 10: ...be reached by the plug on the input cable attached to the welder Mount with the grounding terminal at the top to allow the power cable to hang down without bending 3 Using the instructions in Figure A 1 have a qualified electrician connect the receptacle or cable to the input power lines and the system ground per the U S National Electrical Code and any applicable local codes For long runs over 10...

Page 11: ...fil est employée Placer l interrupteur d alimentation de la machine sur O off avant d installer le pistolet et le câble OUTPUT POLARITY CONNECTIONS The welder as shipped from the factory is connected for electrode positive polarity This is the normal polarity for GMAW process If negative polarity is required interchange the connection of the two cables located in the wire drive compartment near th...

Page 12: ...necteur de Déclenchement de Pistolet du pistolet et du câble au Réceptacle de accouplement en dehors du compartiment situé à gauche de ouverture sur le panneau avant Assurez vous que les rainures de clavette sont alignés insérez et serrez le circlip FIGURA A 2 1 Étirer le câble bien droit 2 Dévissez la Vis de Main sur l embout avant d unité d entraînement compartiment d alimentation de fil d intér...

Page 13: ...su lugar para asegurar el cilindro a la parte trasera de la soldadora 2 Quite la cubierta del cilindro Inspeccione las válvulas del cilindro para verificar que las llaves no estén dañadas que haya suciedad polvo aceite o grasa Quite el polvo o la suciedad con un pedazo de tela limpia NO CONECTE EL REGULADOR SI HAY ACEITE GRASA O ALGUN DAÑO Informe a su proveedor de gas lo anterior El aceite o la g...

Page 14: ...ercas 6 Antes de abrir la válvula del cilindro gire la perilla de ajuste del regulador en dirección opuesta a las manecillas del reloj hasta que se libere la tensión del resorte de ajuste 7 Párese a un lado abra lentamente la válvula del cilindro solo una fracción de giro Cuando el indicador de presión del cilindro deje de moverse abra totalmente la válvula Nunca se pare directamente enfrente o at...

Page 15: ...rode les mains nues ou si l on porte des vêtements mouillés S isoler de la pièce et de la terre Toujours porter des gants isolants secs LES FUMÉES ET LES GAZ peuvent être dangereux Tenir la tête en dehors des fumées Utiliser un système de ventilation ou d extraction pour évacuer les fumées de la zone de travail LES ÉTINCELLES DE SOUDAGE peuvent provoquer un incendie ou une explosion Tenir les mati...

Page 16: ...a de entrada una pistola Magnum 250L GMAW y cable de 12 pies 3 7 m con tobera rociado fija un cable de energía de 10 pies 3 1 m con enchufe y cable de trabajo de 10 pies 3 1 m con pinza y adaptadores del carrete para carrete 2 y 3 de par en par 8 PROCESOS RECOMENDADOS Y EQUIPO El WIRE FEED 255 se recomienda para los procesos de GMAW usando 10 a 44 libras 4 5 a 20 kilogramos 2 51m m Carretes de la ...

Page 17: ...ontrol de Velocidad de Alambre Controla la veloci dad de alimentación de alambre de 50 700 pulgadas por minuto 1 2 17 8 m min La velocidad del alambre cambiará si los cambios se realizan en el control del voltaje RODILLO IMPULSOR DE ALAMBRE Los rodillos impulsores instalados con la WIRE FEED 255 tienen dos surcos uno para el electrodo de acero sólido del alambre del 035 0 9mm y él graneó el surco ...

Page 18: ... 5 Alimente manualmente el alambre del carrete del alambre sobre el surco del rodillo impulsor y a través de la guía de alambre y entonces en el buje de cobre amarillo del montaje del arma y de cable 6 Coloque el brazo de presión de nuevo ajustable a su posición original para aplicar la presión Ajuste la presión como necesaria FIGURA B 2 CARGA DEL CARRETE DE ALAMBRE Para montar bobinas de 10 a 44 ...

Page 19: ...para el calibre y el tipo de alambre que se está utilizando Consulte la Tabla C 1 en la sección de Accesorios 1 Gire el o el carrete hasta que esté accesible el extremo libre del electrodo 2 Al tiempo que sostiene de manera segura el electrodo corte el extremo doblado y enderece los primeros 152 mm 6 Corte los primeros 25 mm 1 Si el electrodo no se encuentra adecuadamente enderezado no podrá alime...

Page 20: ... ejercen en el alambre El ajuste apropiado de ambos brazo de presión da el mejor funcionamiento de la soldadura Fije el brazo de presión como sigue Véase la Figura B 4 Los alambres de aluminio entre 1 y 3 Quitaron el corazón a los alambres entre 3 y 4 El acero alambres inoxidables entre 4 y 5 RÉGLAGE DE LA PRESSION DU GALET MENÉ La DÉCHARGE ÉLECTRIQUE peut tuer La puissance d entrée AU LOIN à la s...

Page 21: ...imadamente 10 mm 3 8 del extremo de la punta de contacto 4 Si se va a utilizar soldadura con gas active suministro de gas y establezca la proporción de flujo que se requiere por lo regular es de 25 35 CFH 12 16 litros min 5 Cuando se utiliza un electrodo Innershield la tobera de gas puede retirarse del aislamiento del extremo de la antorcha y reemplazarse por una tobera de operación sin gas Esta d...

Page 22: ... de manejo de la antorcha a No retuerza o jale el cable sobre esquinas afiladas b Mantenga el cable del electrodo en la posición más recta posible al realizar la soldadura o carga del electrodo a través del cable c No permita que ruedas o aparatos pasen sobre los cables d Mantenga limpio el cable siguiendo las instrucciones de mantenimiento e Utilice únicamente electrodos limpios y sin óxido f Ree...

Page 23: ...uit breaker F2 WELDING THERMAL OVERLOAD PROTECTION The WIRE FEED 255 has built in thremal LED on the front panel and protective thermostats that respond to excessive temperature The yellow thermal LED lights up Also the thermostats open the wire feed and welder output circuits if the machine exceeds the maximum safe operating temperature because of a frequent overload or high ambient temperature p...

Page 24: ... is rated at 200 amps 60 duty cycle or 250 amps 40 duty and is equipped with the integrated connector twist lock trigger connector fixed nozzle and insulator and includes a liner diffuser and contact tips for the wire sizes specified ENSAMBLES DE ANTORCHA MAGNUM GMAW Y CABLES El montaje del arma y de cable de la botella doble 250L se utiliza con el WIRE FEED 255 Esta unidad es clasificada a 200 am...

Page 25: ...lo interruptor entre el uso de la máquina con su alimentador y antorcha o la antorcha Spool Gun para la misma polaridad de soldadura con diferentes procesos de alambre y gas Este pistola no requiere los adaptadores externos y se puede instalar directamente a la máquina Véase la Figura C 1 FIGURA C 1 FIGURE C 1 MAGNUM 100SG Couper toute alimentation d entrée de la machine WIRE FEED 255 avant de com...

Page 26: ...acer tierra y permanecen energizados varios segundos después de que se libera el gatillo de la pistola 1 Operación con la WIRE FEED 255 a ENCIENDA la energía de alimentación de la WIRE FEED 255 b Al ajustar el control de voltaje se aumentará o disminuirá su voltaje de soldadura c Al ajustar el control de velocidad de alambre en la máquina incrementará o disminuirá la velocidad de alimentación de a...

Page 27: ...an motors have sealed ball bearings which require no service DRIVE ROLLS AND GUIDE PLATES After every coil of wire inspect the wire drive mechanism Clean it as necessary by blowing with low pressure compressed air Do not use solvents for cleaning the idle roll because it may wash the lubricant out of the bearing All drive rolls are stamped with the wire sizes they will feed If a wire size other th...

Page 28: ...mm extended for the short circuiting transfer process and 12 3 2 mm recessed for spray transfer GUN TUBES AND NOZZLES a Replace worn contact tips as required b Remove spatter from inside of gas nozzle and from tip after each 10 minutes of arc time or as required GUN CABLE CLEANING To help prevent feeding problems clean cable liner after using approximately 300 pounds 136 kg of electrode Remove the...

Page 29: ... TRIMMING INSTRUCTIONS FOR MAGNUM 250L 1 Remove the gas nozzle and nozzle insulator if used to locate the set screw in the gas diffuser which is used to hold the old liner in place Loosen the set screw with a 5 64 2 0 mm Allen wrench 2 Remove the gas diffuser from the gun tube 3 Lay the gun and cable out straight on a flat surface Loosen the set screw located in the brass connec tor at the feeder ...

Page 30: ... antorcha 6 Con el difusor del gas sin istalar en el tubo de la antorcha asegúrese que el cable esté en posición recta y luego recorte la guía a la longitud Quite cualquier acumulación en el extremo de la guía 7 Atornille el difusor de gas al extremo del tubo de la antorcha y ajuste de manera segura Asegúrese que el difusor de gas sea el correcto para el tamaño de la guía que se utiliza véase Figu...

Page 31: ... il s agissait d un filetage à droite jusqu à ce qu elles atteignent un arrêt Puis tirer sur les viroles pour les sortir du pistolet S il est difficile de tourner les viroles placer la poignée du pis tolet dans un angle placer un tournevis contre la par tie en saillie de la virole et donner un bon coup sur le tournevis pour que la virole dépasse une nervure de verrouillage interne DESENSAMBLE DEL ...

Page 32: ...dor de líneas Revêtement KP42 25 15 KP42 25 15 KP42 4045 15 KP42 4045 15 Nozzle Inyector Bec KP22 50 KP22 50 KP23 50F KP1947 1 Insulator Aislador Isolateur KP32 KP32 x x Gun Pistola Pistolet Magnum 250L Contact Tip Extremidad del contacto Bout de contact KP14 25 KP14 30 KP14 35 KP14 45 Diffuser Difusor Diffuseur KP52 23 KP52 23 KP52FN KP52 Drive Roll Rodillo impulsor Pain d entraînement KP2855 1 K...

Page 33: ...na para ayudarle a localizar y a reparar posibles averías de la máquina Si por cualquier razón usted no entiende los procesos de prueba o no está en la posibilidad de realizar las pruebas reparaciones con seguridad contacte a su Taller DE Lincoln Autorizó la Facilidad del Servicio LASF para la ayuda técnica de la localización de averías antes de usted proceda Para el ayuda en la localización de un...

Page 34: ...l que falla Repare o reemplace 2 Si el problema persiste con el arma nuevo entonces el problema entro de la WIRE FEED 255 TROUBLESHOOTING LOCALIZACIÓN DE AVERíAS DÉPANNAGE Dommages physiques ou électriques impor tants évidents 1 Communiquer avec le service après vente agréé Lincoln local Le fil ne se dévide pas et il n y a pas de tension à vide quand on appuie sur la gâchette du pis tolet Les affi...

Page 35: ...adecuadopara el proceso que se está utilizando La sortie de la machine est faible Les soudures sont froides le cordon de soudure est arrondi ou bombé ou révèle un mauvais mouillage de la tôle 1 Vérifier la tension d entrée S assurer que la tension d entrée correspond à celle de la plaque signalétique et reconnecter la con figuration du panneau 2 S assurer que les réglages de vitesse de dévidage du...

Page 36: ...trucción en la línea de suministro de gas 3 El ensamble del cable de la antorcha puede fallar Verifique o reemplace 4 Si el solenoide de gas no funciona cuando el gatillo de la antorcha se jala el problema se encuentra dentro de la WIRE FEED 255 5 Asegúrese de que la pistola entre hasta el fondo en el montaje de la antorcha y esté bien colocada TROUBLESHOOTING LOCALIZACIÓN DE AVERíAS DÉPANNAGE Mau...

Page 37: ... que el arma está empujado hasta el final en el montaje del arma y asentado correcta mente 8 Compruebe que el pistola está empujado hasta el final en el montaje del pistola y asentado cor rectamente Engraissé pauvre avec l électrode qui est collée ou ruine éteint 1 Assurez vous dont les ajustements pour la vitesse et le voltage du fil corrects pour le processus qui est utilisé 2 Blinder du gaz il ...

Page 38: ...S27985 25 MOTOR CIRCUIT BREAKER WFS POT POT DE WFS POTE DE WFS CONTROL BOARD TABLERO DE CONTROL TABLEAU DE COMMANDE 230V 60Hz FAN MOTOR MOTEUR DE VENTILATEUR MOTOR DE VENTILADOR CONTACTOR ENROULEMENT DE CONJONCTEUR BOBINA DEL CONTACTOR COIL 230V 60Hz GAS SOLENOID SOLÉNOÏDE DE GAZ SOLENOIDE DEL GAS TERMÓSTATOS THERMOSTATS THERMOSTATS MOTOR MOTEUR MOTOR 110 F1 X1 2 X1 1 X3 4 X3 6 X3 2 X3 1 X3 14 X2 ...

Page 39: ...39 28 32 9 84 32 45 30 20 32 70 16 81 30 21 12 15 DIMENSION PRINT CENTURY WIRE FEED 255 IMPRESION DE LAS DIMENSIONES CENTURY WIRE FEED 255 COPIE DE DIMENSION CENTURY WIRE FEED 255 ...

Page 40: ...to Impreso de Control Circuit imprimé de Assemblée S27985 17 Fan Ventilador Ventilateur S27985 18 Twistlock Cable Assembly Asamblea de cable Cerradura de la torcedura Câble équipé de Serrure de torsion S27985 19 Output Stud Fastening Cap Salida del perno sujete Cubierta Rendement de goujon Chapeau d attache S25351 5 Input Cord Cuerda de la entrada Corde d entrée S27985 31 Chain Cadena Chaîne S2798...

Page 41: ...41 NOTES NOTAS ...

Page 42: ...flammable materials away Mantenga el material combustible fuera del área de trabajo Gardez à l écart de tout matériel inflammable Entfernen Sie brennbarres Material Mantenha inflamáveis bem guarda dos Wear eye ear and body protection Protéjase los ojos los oídos y el cuerpo Protégez vos yeux vos oreilles et votre corps Tragen Sie Augen Ohren und Kör perschutz Use proteção para a vista ouvido e cor...

Page 43: ...tzverkleidung in Betrieb setzen Mantenha se afastado das partes moventes Não opere com os paineis abertos ou guardas removidas LEIA E COMPREENDA AS INSTRUÇÕES DO FABRICANTE PARA ESTE EQUIPA MENTO E AS PARTES DE USO E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR READ AND UNDERSTAND THE MANUFACTURER S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER S SAFETY PRAC...

Page 44: ......