APPENDIX A
Up grading CNC10 system with RTK3 PLC from DP-4 to DP-7
Photo 1. Components of up graded probing system
Component descriptions:
1) RTK3 PLC swap out unit with firmware 071206 or newer
2) DSP CONDUIT CABLE assembly number 10956
3) CPU10B swap out unit with cyclone rev 071106 and IO2PIC 071207 or newer
4) INTBRD daughter card with jumpers set for DP7 operation
5) PROBE COIL CORD assembly number 10394
6) RTK3 DIGITIZE CABLE with splice connectors
7) DP-7 PROBE
Photo 1. shows the general interconnection of the components for the DP-7 up grade. The
splice connections are not made until all the cables have been routed. The DSP conduit
cable must be pulled through the conduit to the console where the CPU10B is located.
Control software must be updated to support the operation of the DP-7.
Last Modified 2014-09-16 04:12:44 AM
Page 17 of 21
C:\Users\Keith\AppData\Local\Temp\7zO0E521723\DP7body20140916.odt
2
4
3
1
5
6
7