APPENDIX B
CNC11 CENTROID CONTROL DP-7 PROBE PARAMETERS
Parameter Setting
(mm)
Description
3
0
Modal Tool and Height Offset Control
10
16
Enables decel on probe contact
11
50769
Probe / TT PLC probe input number
12
10
Tool library number for probe
13
0.030 (0.762)
Clearance amount nominal
14
30
(762)
Fast Probing Rate
15
3
(76.2)
Slow Probing Rate
16
5
(127)
Maximum Search Distance
18
50771
PLC input, Probe Detect, Spindle Inhibit
120
0.030 (0.762)
Probe stuck clearance amount
121
0.030 (0.762)
Grid digitizing minimum Z pullback
122
0.0002(0.0051)
Grid digitizing dead band distance
123
0
Radial clearance move
151
0
Repeatability tolerance
155
2
Probe type enable
186
0
Probe stuck retry disable
366
1
Probe Deceleration Multiplier
392
0.030 (0.762)
DP-7 Probe clearance pull-back
393
10
(254)
DP-7 Probe pull-back speed
394
10
(254)
DP-7 measuring feed rate
395
30
(762)
DP-7 set-up traverse feed rate
396
30
(762)
DP-7 set-up plunge feed rate
(see control manual for additional information)
COMMUNICATION CHECK:
Confirm probe is communicating with control. Press <Alt+I> to open the centroid PLC I/O
diagnostic screen. Locate the inputs entered in parameters 11 and 18 typically these are PLC
inputs 50769 and 50771. Verify that they change correctly when the probe is first connected.
50771 will turn on solid green and 50769 and 50770 will flash alternately red green then stay
red. 50770 is a special DP-7 hard wired input. Only the last three digits 769, 770 and 771 are
displayed on the diagnostic screen. Use the F12 and F11 keys to scroll through the diagnostic
screens to find the inputs.
Last Modified 2014-09-16 04:12:44 AM
Page 21 of 21
C:\Users\Keith\AppData\Local\Temp\7zO0E521723\DP7body20140916.odt