14
14
Lightblaster 200 User Manual
Eng
No light, LED cuts out intermit-
tently, or burns out too quickly
LED missing or blown
Disconnect fixture and replace the
LED
Fixture or LED is too hot
Allow fixture to cool. If problem per-
sists, contact service technician*
Fixture resets but does not
respond correctly to controller
(DMX mode operation)
Controller not connected
Connect controller
Incorrect addressing of the
fixtures
Check address setting on fixture and
controller
Bad data link connection
Inspect cables and correct poor con-
nections and/or broken cables.
Conflict between tracking and
vector control
Eliminate scene cross-fade on
controller
Data link not terminated
Insert termination plug in output of
last fixture**
Defective fixture on 2 devices
transmitting on link
Bypass fixtures one at a time until
normal operation is regained: un-
plug both connectors and connect
them directly together
* To contact CentoLight service, see “10 - Warranty And Service” on page 16 or visit