Assembly and operating instructions
CENTAX-G
020G-00050…00090-F.10
M020-00009-EN
Rev. 4
CENTA Antriebe Kirschey GmbH
47 / 52
9.7.3
Removing the rubber element (1.1) with the ring (1.4)
See Fig. 6-8:
Together with the ring (1.4) and the dismantling supports remove the rubber
element (1.1) out of the installation space.
9.8
Removing the ring (1.4)
See Fig. 6-6:
Pull the ring (1.4) out of the rubber element (1.1) and remove.
9.9
Dismantling the membrane (1.2.1)
See Fig. 6-5:
Remove the membrane (1.2.1) and the ring (1.9; only at sizes
00050…00075) from the flange/hub/adapter (E/3/17).
9.10
Dismantling the adapter (17; if existing/ necessary)
See Fig. 6-4:
Loosen the screws of the connection adapter (17) and the flange/hub (E/3)
and remove.
Push the adapter (17) off/out of the centring of the flange/hub (E/3) and
remove.
9.11
Dismantling the hub (3; if existing/necessary)
Dismantle the hub (3) as appropriate for the supplied design (see installation
drawing).
Dismantling the hub with cylindrical bore and keyway, see chapter
9.11.1.
Dismantling the hub with conical oil interference fit, see chapter 9.11.2.
9.11.1
Dismantling the hub with cylindrical bore and keyway
See Fig. 6-1:
Remove the hub (3) from the shaft (A).