Mounting the membrane (coupling sizes 00050…00075)
Fig. 6-12 Mounting the membrane (coupling sizes 00050…00075)
Item
Info
Designation
Remark
1.2.1
Membrane
1.4
Ring
Covered by membrane
(1.2.1)
1.9
Ring
1.10
Screw ISO4762-10.9
3
Hub
If scope of supply
17
Adapter
If scope of supply
E
Flange
Customer part
Push the membrane (1.2.1) onto the centring of the flange/hub/adapter
(E/3/17).
Push the ring (1.9) onto the centring of the flange/hub/adapter (E/3/17).
Screw the ring (1.9) and the membrane (1.2.1) to the ring (1.4) using the
screws (1.10).