Description of the machine
22
Rev. 10/17
Brave 30 ES - Brave 60 ES - Brave 90 ES
3.5.2 Optional functions
Compressor delivery tube temperature check
This function allows you to monitor the compressor delivery temperature: if the safety limit is
exceeded, the warning message
"HIGH TEMP COMPR
” is displayed. The machine functions are
not interrupted, and the message disappears as soon as the temperature returns within
acceptable limits. This message can be transmitted via telemetry, if present.
Carbonation pump body temperature check
This function allows you to monitor the carbonation pump body temperature: if the safety limit is exceeded,
the warning message
"HIGH T CARB PUMP
” is displayed. The machine functions are not interrupted, and the
message disappears as soon as the temperature returns within acceptable limits. This message can be
transmitted via telemetry, if present.
Soda recirculation temperature check
This function allows you to monitor the soda recirculation temperature: if the safety limit is exceeded, the
warning message
"HIGH T REC SODA P
" is displayed
.
The machine functions are not interrupted, and the
message disappears as soon as the temperature returns within acceptable limits. This message can be
transmitted via telemetry, if present.
Tank water temperature check
This function allows you to monitor the temperature of the water in the tank: if the safety limit is exceeded,
the warning message
"HIGH T H
2
O
BATH” is displayed. The machine functions are not interrupted, and the
message disappears as soon as the temperature returns within acceptable limits. This message can be
transmitted via telemetry, if present.
Anti-flooding check (with probe)
This function detects the presence of water in the machine area or immediate vicinity, thanks to a probe.
The presence of water in these areas indicates a possible water leakage. In this case an alarm (
"WATER
LEAKAGE
”) is displayed on the screen, the power supply to the dispensing tower is cut off, and the water
inlet valve is closed (if present). Any acoustic or light signal present on the dispensing tower is activated. The
alarm condition can be removed by pressing the RESET button once you have checked that the system is
working correctly. The alarm is transmitted via telemetry, if present.
Anti-flooding control (with flow meter)
This function detects a continual ingress of water into the machine for a prolonged period (time-out). The
continual ingress of water, for a period exceeding a certain value, indicates a possible leak in the water
circuit. In this case an alarm (
"IN H
2
O
TIME OUT
”) is displayed on the screen, the power supply to the
dispensing tower is cut off, and the water inlet valve is closed (if present). Any acoustic or light signal present
on the dispensing tower is activated. The alarm condition can be removed by pressing the RESET button
once you have checked that the system is working correctly. The alarm is transmitted via telemetry, if
present.
Inlet water measuring function
This function uses an optional flowmeter to measure the quantity of water entering the machine. This
function is useful for controlling the water filter and calculating drink consumption levels. The quantity of
dispensed water can be monitored via telemetry.
Inlet water pressure check
This function allows you to monitor the inlet water pressure. If the pressure is too low, there may be
problems with the pumps and dispensing of drinks which are not up to standard. In this case an alarm (
"H
2
O
IN PR LOW
”) is displayed on the screen, the power supply to the dispensing tower is cut off, the water inlet
valve is closed (if present), and the drainage function is disabled (see "Bacteria proliferation prevention").
Any acoustic or light signal present on the dispensing tower is activated. The machine functions are restored,
and the message disappears as soon as the water pressure returns within acceptable limits. The alarm is
transmitted via telemetry, if present.
Inlet CO
2
pressure check
This function allows you to monitor the inlet CO
2
pressure. If the pressure is too low, there may be problems
with the dispensing of drinks which are not up to standard. In this case an alarm (
"CO
2
IN PR LOW
”) is
displayed on the screen, and the power supply to both the dispensing tower and the carbonation and still
water pumps is cut off. Any acoustic or light signal present on the dispensing tower is activated. The machine