![Ceke DTV-UDWG100F User Manual Download Page 24](http://html1.mh-extra.com/html/ceke/dtv-udwg100f/dtv-udwg100f_user-manual_2579051024.webp)
DTV-UDWG100F User Manual
Guilin CEKE Communication Equipment Co., Ltd.
Add: D-08, Information Industrial Park, Chao Yang Rd, High-tech District, Guilin, Guangxi, 541004, P.R.China.
Tel: +86 773 2120 156 Fax: +86 773 2120 299 Email
:
[email protected] Web: www.glsq.com
23
9.2 Repeater 3.52 Program Client Interface Introduction:
1.Information
Equipment
information
Info(start-up informtion)
GUILIN SIQI REPEATER
2.FORD Pow
Output power
3.REF Pow
Reflection
power
4.ATT
ATT
attenuation
value
6.TEMP
Temperature
2.alarm
Alarm
information
3.setup
System setting
7.PA status
Power
Amplifier
status
8.FAN status
1.AGC set
Power setting
1.PRE-AMP RF in
Preamplifier
input
2.PRE-AMP status
Preamplifier
status
3.TEMP
temperature
4.FORD Pow
Output power
5.REF Pow
Reflection power
6.MAIN DC power
supply
Power voltage
2.ATG set
3.exturn ATT
Additional
attenuation value
4.MAX input
power
Preamplifier
maximum power
5.MAX FORD
Power
Maximum output
power
6.MAX REF
Power
Maximum
reflection power
7.MAX DC
Power
Power supply
upper limit
Set output power
0~176
input signal corresponding to
attenuation values
Automatic(default)
-15~-25dB attenuate 30dB
-25~-35dB attenuate 20dB
-35~-45dB attenuate 10dB
-45dB below attenuate 0dB
The above attenuation value
applies to -15~-60 dB RF signal
strength, optical fiber received
signal strength should plus 30
dB based on RF signal strength.
Set preamplifier output
maximum protection
point (general 2.5 V)
Set maximum output power
protection point(maximum
add 40%)
)
Set maximum reflection
power protection point
(
maximum add 4 times)
Set main power supply
voltage upper limit
protection point
9.A_FWD
Output power
Detection
voltage
7.first alarm
8.Second alarm
9.Thrid alarm
Password
Enter password
(
default 0000
)
Temperature
compensation
(
default
open enable
)
8.MIN DC Power
Power supply
lower limit
Set main power supply
voltage lower limit
protection point
9.Password set
Password setting
Navigation key for setting
password
ENT key for confirmation
4.System set
GPRS setting
Pass word
Enter password
(
default
0000
)
1.id
Equipment ID
2.version:3.52
Version No.
3.Model:00
.
Mode
4.GPRS:Enable
5.Server IP
Server IP ADD:
222.052.140.130
6.Server Port:
Server port 7300
7.Report inter
00H10M
Report time
1.AGC state
AGC ready
state
5.AGC
AGC value
10.DC power
Power supply
voltage
Remarks: There are two repeater programs: 3.3(short message module) and 3.52(TCP
data module). They vary only on
4.system set, others
are the same. Please check
version number in
4.system set-GPRS setting-2.version 3.52.