Safe2+ / Safe4
Operation Manual
22 www.cedes.com
©
CEDES
Safety & Automation AG / June 2008
11. Technical
Data
Table 6
Description
Value
Remarks
Profile length
120 ... 2'760 mm
Selection table page 19
Operating range
0 ... 9 m
0 ... 18 m, optional 6 or 5 up to 30 m
Resolution 14 mm
Resolution 30 mm
Object detection capability
(Resolution)
14 mm
30 mm
Other resolution on request
Power supply U
sp
24 VDC ± 20 %
PELV, IEC 60 204-1
Power supply ripple
< 10 % of U
sp
Equipment Class
III
VDE 0106 part 100
Time for self check when switching
on U
sp
< 3 s
Current consumption
< 500 mA
No-load operation
Outputs, short circuit proof
2 x PNP, 0.3 A
Max. capacitive load 0.5
µ
F
Output voltage
> U
sp
– 1
Load 0.1 A
Response time t
R-BWS
Selection table
Page 17
Connector
7 pins, spacing 3.81 mm
WAGO M16
Connection cable
Max length 60 m
Cross section max. 1.5 mm
2
Cable gland
- axial
- radial
M 16
M 12, 5-Pin
Outside diameter of cable
3 ... 6.5 mm
3.5 ... 10 mm
for M12
for M16
Mode of operation
Guard only with automatic restart
Safety category
Type 2 (Safe2+), Type 4 (Safe4)
Self testing
Standards
IEC 61496 part1+2
Electromagnetic compatibility
(EMC)
IEC 61 496 part 1
Enclosure rating
IP65
Temperature range
0 ... +55°C
-20 ... +60°C
Operation with ILAS
Storage / transport
Relative air humidity
15 ... 95 %
Not condensing
Enclosure
Aluminum profile 30 x 40 mm
Optical window
Polycarbonate, bonded
Optional: Coated polycarbonate,
scratch resistant
Enclosure treatment
Polyester powder coated
Silicon free manufactured
ILAS
Laser class 2
EN 60 825
Dimensions
Dimensions and selection tables
Pages 16, 17 + 19
Weight
Selection tables
Page 19