Mechanical
The Radiance 5 requires 21” counter space and the
Radiance 10 requires 31.25”. Height of all units with
door open is 42.5” for Radiance 5 and 46.5” for
Radiance 10. The units weigh approximately 118 and
150 pounds empty and 213 and 300 pounds full of
water and product.
Electrical
A NEMA 5-15R receptacle is required on a dedicated, 15
amp circuit.
Water Supply
The Radiance beverage dispenser can use any standard
municipal water supply as well as any commercial-grade
filtered, reverse osmosis, distilled, de-ionized, or
purified water.
This machine must have a water supply of between 20
and 100 psi of line pressure with a ¾” standard garden
hose fitting to the inlet valve of the machine. Any water
supply not compliant with the required 20 – 100 psi
range must be pressure regulated accordingly. It is
recommended to install a manual shut-off valve
between the main water supply and the machine.
This machine and any associated water supply lines
must be compliant and maintained in accordance with
all local, state and federal laws associated with
commercial beverage dispensing equipment and use of
potable water supply lines. Water pipe connections and
fixtures directly connected to potable water supply shall
be sized, installed, and maintained in accordance with
Federal, State, and Local codes. (Required for NSF
approved water hook-up)
Note:
In areas with water hardness above 5 grains, a
water softener must be installed and maintained in
order to prevent mineral deposits that will cause
malfunctioning of the equipment.
Water Inlet Connection requirements:
The following is required for water connection:
1. A 3/4" GHT NSF approved flexible hose for
hook-up to water supply.
2. Installation to a water filter system is
suggested to prevent lime and mineral scale
build up in the machine.
3. Equipment must be installed with adequate
backflow protection to comply with
applicable Federal, State, and local codes.
(Required for NSF approved water hook-up)
Electrical Connection requirements
Always ensure that the machine power switch is in the
OFF position and unplugged from power supply when
making or maintaining electrical connections.
This appliance is equipped with a three wire power
cord. A dedicated three wire 120V, 15A, electrical circuit
must be used.
Location requirements
This machine must be located on a level surface that can
support 400 pounds across a span as wide as the
machine.
CAUTION
:
Lifting hazard. Single person lift
could cause injury. It is recommended that moving or
lifting the unit be done by two people to avoid injury.
NEMA 5-15P
Radiance Technical Service Manual
Cecilware
®
5
Specifications (continued)
Installation
NOTICE:
Do not reuse old hose. Only use new hose.