![Cebora PLASMA PROF 164 HQC Service Manual Download Page 53](http://html1.mh-extra.com/html/cebora/plasma-prof-164-hqc/plasma-prof-164-hqc_service-manual_2577545053.webp)
CEBORA S.p.A.
53
5.12
- Control box board (5), code 5.602.033 (on module HV18).
5.12.1
- Topographical drawing.
5.12.2
- Connector tables.
Conn. Terminals
Function
J1
A - B
NU. (start input from torch button).
J2
A - B
“guard open” signal output, on module HV18.
J3
-
Power Source output voltage input, nozzle potential.
J4
-
output voltage output for torch, nozzle potential.
J5
1 - 2
NU.
J5
3 - 4
“guard open” signal input, on module HV18.
TP1
output voltage output, nozzle potential, for HF board (2).
TP2
output voltage output, electrode potential, for HF board (2).
TP3
output voltage input, from Power Source, electrode potential.
5.13
- HF board (2), code 5.602.034 (on module HV18).
5.13.1
- Topographical drawing.
5.13.2
- Connector table.
Conn. Terminals
Function
-
CN1 - CN4
output for HF transformer (7) primary circuit, on module HV18.
-
CN2
output voltage input, nozzle potential, from control box board (5).
-
CN3
output voltage input, electrode potential, from control box board (5).
3.302.218