![Cebora PLASMA PROF 164 HQC Service Manual Download Page 50](http://html1.mh-extra.com/html/cebora/plasma-prof-164-hqc/plasma-prof-164-hqc_service-manual_2577545050.webp)
CEBORA S.p.A.
50
5.8
- Torch board (42), code 5.602.266.
5.8.1
- Topographical drawing.
5.8.2
- Connector table.
Conn. Terminals
Function
J1
-
NU.
J2
-
NU (torch recognition).
J3
A - B
“guard open” signal input, on Power Source and module HV18.
J4
-
NU.
J5
A-B
output voltage output, nozzle potential.
J6
A-B
output voltage input, nozzle potential.
J7
1-2-3 / 4
output signals for torch recognition.
J7
5 - 6
NU.
J7
7(+) - 8(-)
“nozzle protection” output signal.
J7
9(+) - 10(-)
“guards open” signal output, on Power Source and module HV18.
J7
11(+) - 12(-)
“torch adapter protection” signal input.
J8
4(+) - 1(-)
“Power Source output voltage” signal input.
J9
-
NU.
J10
-
NU.
J11
1 - 2
8 Vac torch board (42) power supply input.
J12
1 - 2
24 Vac torch board (42) power supply input.
J13
1(+) - 2(-)
“arc voltage” digital signal output.
J13
4(+) - 5(-)
“nozzle voltage” digital signal output.
J14
1(+) - 2(-)
“arc voltage” signal output, for remote board (59).
J15
1(+) - 2(-)
“auxiliary arc voltage” digital signal output.
3.302.218