CEBORA S.p.A.
52
5.11
- Remote board (59), code 5.602.252.
5.11.1
- Topographical drawing.
5.11.2
- Connector table.
Conn. Terminals
Function
J1
-
GND.
J2
1 - 9
“start” signal input.
J2
2 - 10
“emergency stop” signal input, from system.
J2
3 - 11
“operating permission” (interlock) signal input, from system.
J2
4 - 12
“transfer arc” signal output.
J2
5(+) - 13(-)
external analog current reference input.
J2
6(+) - 8(-)
“isolated arc voltage” signal output.
J2
16(+) - 8(-)
“not isolated arc voltage” signal output.
J3
1 - 2
“transfer arc” signal input.
J3
3(+) - 4(-)
external digital current reference output.
J3
5(+) - 6(-)
“operating permission” (interlock) signal output, from system.
J3
7(+) - 8(-)
“emergency stop” signal output, from system.
J3
9(+) - 10(-)
“start” signal output.
J4
1(+) - 2(-)
“arc voltage” signal input, for remote board (59).
J5
1 - 2
230 Vac input, for remote board (59) power supply.
J6
1(+) - 2(-)
“auxiliary arc voltage” digital signal input.
3.302.218
9/8/2006