![Cebora 448.00 Instruction Manual Download Page 22](http://html1.mh-extra.com/html/cebora/448-00/448-00_instruction-manual_2577457022.webp)
3301070/C
19/09/2022
CEBORA S.p.A.
22
IT
Dati tecnici ingressi e uscite.
EN
Inputs and outputs technical data.
ES
Datos tecnicos entradas y salidas.
Digital inputs (connectors J7, J8, J10, J11).
input current
5 mA, min.;
input frequency
100 Hz, max.
Analog inputs (connector J12).
Analog voltage output (connector J5).
output voltage range
0 ÷ 10 Vdc;
output current
20 mA max.;
output frequency
5 Hz.
output impedance
200 Ω
Analog current output (connector J5).
input voltage range
0 ÷ 10 Vdc;
voltage resolution
10 bits;
input frequency
15 Hz max.
input impedance
1MΩ
Digital outputs (connector J3).
output current range
4 ÷ 20 mA;
output voltage
15 Vdc max.;
output frequency
5 Hz
output voltage
24 Vdc;
output current
50 mA. max;
output frequency
100 Hz max.