![Cebora 208-10 Instruction Manual Download Page 40](http://html1.mh-extra.com/html/cebora/208-10/208-10_instruction-manual_2577434040.webp)
CEBORA S.p.A.
40
3.300.189-B
04/03/2016
GB
7.8
Soft Start (Acc).
This regulation is important in order to obtain good starts.
Soft start is the wire speed, expressed in percentage of wire speed set for welding, before that the wire
touches the workpiece.
Press for a time longer than 3 seconds the key
E
to enter the “Second Functions” menù.
Use knob
N
to select
Acc
on display
O
; with knob
Q
select the Soft Start speed level, visible on display
P
(indication expressed in percentage).
Regulation range: Auto or 1 ÷ 100%, default =
Au
, automatic.
NOTE: In order to verify the value corresponding to the default value, rotate of a single step clockwise
the knob
Q
, when display
P
indicates
Au
, and subtrac “1” to the value that appears on display
P
.
Obviously, after such operation, rotating counter-clockwise of a single step knob
Q
, the operation
will be set to the value visible on display
P
but not automatic. In order to restore the automatic
operation (default) press for a time longer than 3 seconds the key
AZ
.
Press briefly the key
E
to exit the “Second Functions” menù, saving all current settings automatically.
7.9
Burn-Back Time Correction (bb).
Regulation for the wire length exiting the torch nozzle after welding, expressed as a time interval
(milliseconds).
Press for a time longer than 3 seconds the key
E
to enter the “Second Functions” menù.
Use knob
N
to select
bb
on display
O
; display
P
shows the function value (indication expressed in
milliseconds).
Correction regulation range: -125 ÷ +125 ms.
The
Burn-Back Time
effective value after the correction is always comprised between 4 ms. and 250 ms.
When the correction set up is equal to 0 the
Burn-Back Time
parameter is set to its default value,
indicated with
Au
(automatic).
The
Burn-Back Time Correction
adjustment is enabled or disabled by means the
Burn-Back Time
Correction Disable
function, available on RAI211 and RDI210 Robot Interfaces.
The corresponding bit is controlable with dip switch S1-4 on RAI211 Robot Interface or with the signal
“I100” of the Data-In Process Image on RDI210 Robot Interface (see Robot Interface Instruction
Manual):
-
with
“Burn-Back Time Correction Disable”
not active (S1-4 = OFF, or I100 = low) the
“Burn-
Back Time Correction”
adjustment is enabled in
Standard program,
Pulsed arc program
and
Manual
modes, and follows the value set at Robot Interface analog input 4. The adjustment is carried
out via Robot Terminal;
-
with “
Burn-Back Time Correction Disable
” active (S1-4 = ON, or I100 = high) the “
Burn-back
Time Correction
” is not active.
Independently from the
Burn-Back Time Correction Disable
function state, in
Parameter Selection
Internal mode
, is always possible to adjust the
Burn-Back Time Correction
from Control Panel.
When the Control Panel is operating, knob
Q
executes the
“Burn-Back Time Correction”
function
value regulation and the key
AZ
, pressed for a time longer than 3 seconds, resets the function to the
default value (
Au
on display
P
).
NOTE: In order to verify the value corresponding to the default value, rotate of a single step clockwise
the knob
Q
, when display
P
indicates
Au
, and subtrac “1” to the value that appears on display
P
.
Obviously, after such operation, rotating counter-clockwise of a single step knob
Q
, the operation
will be set to the value visible on display
P
, but not automatic. In order to restore the automatic
operation (default) press for a time longer than 3 seconds the key
AZ
.
Press briefly the key
E
to exit the “Second Functions” menù, saving all current settings automatically.