![Cebora 208-10 Instruction Manual Download Page 29](http://html1.mh-extra.com/html/cebora/208-10/208-10_instruction-manual_2577434029.webp)
CEBORA S.p.A.
29
3.300.189-B
04/03/2016
GB
4
MANAGEMENT VIA CONTROL PANEL.
4.1
“Robot” function.
Control Panel operations depend on the status of the “Robot” function, indicated by led
AT
(fig. 4).
led
AT
off = “Robot” function not active;
led
AT
lit
= “Robot” function active.
With the “Robot” function not active (led
AT
off) the Control Panel maintains full management of the
Welding System, except for the welding command,
Arc-On
signal, which must always be provided by
the Robot Terminal.
With the “Robot” function active (led
AT
lit), operation of the system switches to the Robot Terminal and
the Control Panel maintains partial operation, conditioned by the “Operating Mode” selected.
To enable the “Robot” function press for a time longer than 3 seconds the key
AV
. Led
AT
lights on.
To disable the “Robot” function press newly for a time longer than 3 seconds the key
AV
. Led
AT
lights
off.
With the “Robot” function active, if the Robot Interface is disconnected or not powered, on Control Panel
the displays
O
and
P
read “
rob
int
” flashing (Power Source - Robot communication interrupted).
NOTE: This Instruction Manual refers to the Control Panel art. 208.10 in Robot applications. Only
operation with the “Robot” function active (led
AT
lit) and commands and signals based on this
selection are described below.
fig. 4