Junction Dialing Controls
.
Junction dialing facility can be controlled Extension wise as below
:
Dial #
0000 + 40 NN L #
where, NN= Last 2 digits of Original Extension number.
L = 0 - The Extension can dial only the numbe
rs starting with digits defined in “Allowed Table”
1 - The Extension can dial all numbers.
2 - The Extension can dial all numbers except for ISD numbers.
3 - The Extension can dial all numbers except for STD numbers.
4 -
The Extension can dial all numbers except for the numbers starting with digits defined in “Denied
Table-
A”
5 - The Extension can dial all numbers except for the numbers starting with digits defined
in “Denied
Table-
B”
6 - The Extension cannot dial out but can make internal calls.
To give all extensions the same L value:
Dial #
0000 + 40 L #
Note
:
In default: all extensions are in L = 1 mode.
:
In dialing out facility is disabled through this program then #9 for Call Pick up will not work. To keep it working, lock
dialing through “Junction Access Control”
.
Junction Call Hold + Tr Making multiple calls
.
To transfer a Junction line to another extension, FLASH and dial the Extension number while talking on the junction line.
Now there can be following 4 conditions:
1. When called extension lifts, calling extension can converse and then keep the Handset down. The Junction call will
then get transferred.
2.
Called extension lifts but doesn’t want to talk then he may keep the Handset down.
The call will come back to the transferring extension.
3. The called extension is ringing but not lifting the Handset. Keep the Handset down.
The call will ring on the called extension for 25 secs and if not answered it will ring back on the transferring extension.
Now if the Transferring extension is busy, the Junction call will be disconnected by the PBX.
If the user wants to disable this auto call back in case of No Answer while transferring a Junction call, program as
below
:
Dial #
0000 + 163 # (Now the Junction call will disconnect if the called extension does pick the call within 25 secs)
To shift back to auto call back mode
:
Dial #
0000 + 162 #
4. If the called Extension is engaged, the user will hear 2 tones. Now FLASH to get back to the Junction line. If FLASH is
not done within 10 secs, the Junction line will get connected. This is the default setting in the PBX.
Alternately the user can change to the following mode
:
On dialing an engaged extension user would get engaged tone. During the engaged tone user can FLASH and get
connected to the Junction line.
Programming
:
Dial #
0000 + 1531 #
To shift back to the default setting, Dial #
0000 + 1530 #
Making two or more Junction calls from SLT
While talking on one Junction line,
FLASH
Dial ## - To park the call
Dial 9 to take another Junction
Dial the required Telephone number
FLASH
Dial ## - To retrieve the first parked call
Similarly, more calls can be made.
.
Junction Dialing Delay Time
.
This is the time after the last digit dialed by an extension on Junction Line.
It is 5 secs in default.
The PBX assumes call maturity from after the lapse of this time.
The FLASH function to Hold an Incoming Junction call starts working after the lapse of this time.
To change this delay time, Dial #
0000 + 03 TT # Where, TT= 01 to 99 secs. Default value = 05 (5 secs)
.
Junction Grouping
.
Two set of Junction groups can be made. One group can be accessed say by dialing 9 and the other group of Junction
lines by dialing a selected code.
Programming:
Dial #
0000 + 0720 # - To enable Manual LCR mode
Dial #
0000 + 077 J #
Where, J = 1 - 8 Junction number to be set in 2
nd
Junction Group. More than one Junction can be
defined in the group by repeating this program.