background image

c.  If Your Faucet Requires More Room for the Diverter Valve Connection:

Some faucets, particularly sprayer hose faucets, require additional 
room for the diverter valve connection. If this applies, attach the 
long adapter, part# MC257, to the opening of the faucet spout/
sprayer, and then attach the diverter valve to the adapter. The CB-
As may need to be repositioned on the sink to allow enough room 
for sprayer faucet use.

d.  If the Adapters Do Not Fit Your Faucet:

Although the adapters included with your CB-As allow connections 
with many standard faucets, they do not cover every type of 
available faucet connection. If none of the adapters allow the 
diverter valve to connect to your faucet, please contact your 
Dealer, to request part# MC105, part# MC109, or part# MC719 as 
possible adapter solutions.

NOTE: 

When connected properly, the hose from the diverter valve 

should lead toward the back of the faucet and sink.

3. 

The diverter valve features a bypass lever with a button on the left and 
right sides of the diverter valve. Press the left button to bypass the DWS 
and  select  the  unfiltered  water  spout  (larger  opening).  Turn  on  your 
faucet to let unfiltered water flow out of the diverter valve and to make 
sure that the diverter valve is properly connected.

4. 

Turn off the faucet.

5. 

Proceed to section 

Connect the Tubing to the Housing (Pg 14)

.

19

The CB-As can be used inline for connection to refrigerators, water coolers, 
or ice makers, so that all of the water from the cold water outlet or faucet is 
filtered. CB Tech recommends that a professional plumber install the system 
for inline use.

Inline Installation

Summary of Contents for CB-As

Page 1: ...istance is required please contact your Dealer If Dealer is unavailable please contact CB Tech at 866 622 9373 Before You Begin Please read this manual before proceeding with the installation and use...

Page 2: ...umbers Below Sink Installation Below Sink Kit CBK1 Required 2 Item 1 2 3 4 5 6 7 8 9 10 11 12 13 14 The acrylic base Item 12 is an optional part available for purchase Part MC652 MC780 MC741 MC741 011...

Page 3: ...8 configuration 14 Adapta Valve 1 2 configuration threading adapter riser angle stop valve 14 water supply line with Adapta Valve in 3 8 configuration water supply line with Adapta Valve in 1 2 confi...

Page 4: ...your particular plumbing configuration requires fixtures different from those included with your shipment please contact your Dealer The following tools are recommended to install your DWS for below...

Page 5: ...he drilling location 3 If you have a porcelain ceramic or cast acrylic sink CAUTION Porcelain ceramic and cast acrylic surface materials are extremely hard and can easily crack or chip Use extreme cau...

Page 6: ...instructions for your faucet type 1 For a standard faucet proceed to section Installing the Standard Faucet Pg 6 2 For a capacity monitored faucet proceed to section Installing the Capacity Monitor Fa...

Page 7: ...7 cover plate countertop plastic washer wing nut large black washer lock washer blue tubing small black washer Complete Faucet Assembly with Blue Tubing MC652...

Page 8: ...city indicator plate tubing for housing countertop Capacity Monitor Assembly 1 3 6 7 9 4 5 12 13 8 2 14 5 15 15 11 10 8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Faucets with Capacity Monitor Include Spout...

Page 9: ...ween the sink and the stud nut b Slide the hard plastic washer 11 upward over the blue tubing 5 black track washer 10 black wire 8 and faucet stud 4 c Slide the lock washer 12 upward over the faucet s...

Page 10: ...As OUTLET into the adapter 15 on the INLET 5 side of the FMU the tubing should typically be inserted 5 8 into the adapter The inlet side is the side from which the arrow points away on the capacity f...

Page 11: ...Reinsert the battery holder d Press and hold the check reset button on the FMU for six 6 seconds You should hear a long audio sound and the LED Display Plate will flash red and then green several tim...

Page 12: ...er Adapta Valve 3 8 configuration water supply line with Adapta Valve in 1 2 configuration 1 2 slip joint nut riser angle stop valve 3 8 slip joint nut Water supply line before installation Adapta Val...

Page 13: ...supply line and slip joint nut detach from either the angle stop valve or the faucet pipe 5 Connect the Adapta Valve to the pipe from which you removed the slip joint nut a Align the Adapta Valve to...

Page 14: ...ot use scissors 2 Fully insert the tubing into the adapter on the OUTLET port of the system housing the tubing should be inserted 5 8 into the adapter NOTE When pushing the tubing into the adapter you...

Page 15: ...1 Attach the metal bands to the mounting bracket a Using a slotted flat blade screwdriver loosen the connector screw on each of the two metal bands so that the slotted side of the bands separate from...

Page 16: ...bracket to the wall ensuring it is oriented in an upright position The bracket is in an upright position when the larger holes on each flat mounting plate on the sides of the bracket are at the botto...

Page 17: ...on the acrylic base with the ports and tubing facing down so that the tubing can feed through the openings at the side of the acrylic base 2 Diverter valve Used to connect the dual hose from the CB A...

Page 18: ...any faucets with an outside thread the diverter valve can attach directly to the faucet If the diverter valve is too small to attach to the faucet attach the inside thread female connector adapter par...

Page 19: ...t your Dealer to request part MC105 part MC109 or part MC719 as possible adapter solutions NOTE When connected properly the hose from the diverter valve should lead toward the back of the faucet and s...

Page 20: ...iv Adjust the Angle Stop Valve or water shutoff valve so that the water flow to the drinking water faucet does not exceed the flow rate NOTE It takes approximately 15 seconds to fill a quart at 1 0 g...

Page 21: ...e including without limitation the implied warranties of merchantability and fitness for a particular purpose to any person This limited warranted may not be altered varied or extended except by a wri...

Page 22: ...buttons on the diverter valve several times to lubricate it thoroughly 4 Reconnect the diverter valve to the faucet Dissolving requires vinegar may cause discoloration to the metal 1 Unscrew the dive...

Page 23: ...Notes...

Page 24: ...600 60 6046 1116 7251 Cathedral Rock Drive Las Vegas NV 89128 866 622 9373 www CarbonBlockTech com...