SMS with data after SaSat:

                        

 
FA-20 supports SMS after 

SaSat: 

Standard for SMS format for transfer of logged values for 

example an electric meter for a data acquisition system via SMS. 

 
Service SMS with field strength measurement etc.:

                        

 
FA-20 is able to send a service SMS to for example a regular mobile phone of the installers. 
The service SMS contains among other things information about current GSM field strength, 
pulse counters etc. The installer orders the service SMS by sending a regular text SMS to the 
FA-20 containing a password. 

  
"Dial-back": 

                                 
FA-20 also supports the "

Dial-back

” principle, which is based on, the FA-20 takes initiative to 

communicate  data  back  to  IT  centre.  The  initiative  may  be  due  to  time  for  routine 
communication,  alarm  recognition  or  key  press.  FA-20  is  programmed  to  carry  out  routine 
communication either fixed routine every hour, day, week, month, 3. month or freely defined. 
The interval between routine communications can be changed from the IT centre with effect 
from the following communication.          

 

To ensure against to many FA-20’s taking initiative to communicate on the same time, all FA-
20 are equipped with special software. FA-20 chooses to delay the initiative to communicate a 
random number of minutes, within a time window, which is programmable from the IT centre.   
 
FA-20 also supports ”dial-back” at absolute time, where it is the main station who chooses the 
time including date and month, in which the FA-20 needs to take initiative to communicate.  
 

Duration: 
 

               

Transport  of  data  including  establishment  of  connection  will  last  (depending  of  chosen 
communication method and local GSM conditions) from 15 seconds and up to more then 10 
minutes,  if  all  logged  values  shall  be  retrieved  (the  total  logged  memory)  and  if  a  download 
also  needs  to  be  performed  (installation  of  new  firmware  to  the  FA-20).  The  IT  centre 
acknowledges  itself,  how  many  log  data  it  is  necessary  to  transfer  and  controls  the 
communication after this.   
 

Internal interval counter:

         

 
The FA-20 will log the total call duration in an internal counter with a resolution of 1 second as 
an extra control option. 
 

Protocol:

                

 
The  FA-protocol  is  a  full  two-way,  commando  oriented  ACK/NAK  protocol  with  BCC-check, 
format-  and  value  validation.  There  are  used  encrypted  passwords  on  multiple  levels.  The 
protocol  creates  possibility  for  extensive  parameter  programming  possibilities,  where  the 
parameter  setup  is  chosen  via  menus  on  the  IT  centre  and  installed  on  to  the  FA-20  via 
GSM/GPRS  communication.  When  GPRS  is  used  the  FA-protocol  is  still  used  as  the  data 
carrying translation protocol, which are transported in the TCP/IP protocol.   

Summary of Contents for FA-20

Page 1: ...RS SMS based remote metering 1 FA 20 in brief 2 Product information 3 Installation Instructions Rev 2013 02 01 CB Svendsen A S Kirke Vaerloesevej 22 24 DK 3500 Vaerloese Denmark Phone 45 4448 5286 Fax...

Page 2: ...lses can be freely mixed FA 20 is delivered preprogrammed with a number of serial meter drivers supporting different serial manufacturer protocols Changing between the drivers is easily done trough SM...

Page 3: ...3 FA 20 Product information...

Page 4: ...is exceeded these conditions will be transmitted to the main station through an extraordinary data communication programmable Furthermore the FA 20 saves 3 sets of serial readings The latest reading...

Page 5: ...o of days 24 h 1h logging 31 27 24 22 20 18 The FA 20 is remotely programmed from the main station logging parameters set up and selection of buffers to which data is logged Logging of pulses and seri...

Page 6: ...a random number of minutes within a time window which is programmable from the IT centre FA 20 also supports dial back at absolute time where it is the main station who chooses the time including date...

Page 7: ...can preserve its content Log data and for example the latest monthly reading is always stored in the F RAM which does not need a battery to preserve its memory FA 20 features a special integrated cir...

Page 8: ...4 band GSM module Temperature range 20 to 45 Relative humidity 15 to 95 not condensing Density class IP54 Dimensions 105 x 180 x 50 mm W x H x D without antenna Remember 30 mm clearance for cable entr...

Page 9: ...ultical 801 via data module an without compatability module KM6 data module is mounted internally in 801 8 Div Multical with M bus module mounted internally in Multical Max M bus 9 Unigas 61E via data...

Page 10: ...10 FA M2000 GSM main station modem...

Page 11: ...s ready for use and special settings of parameters can be installed and stored permanently in the GSM modems memory FA M2000 supports V 110 data communications which allow data to be transferred at sp...

Page 12: ...12 Installation guide FA 20...

Page 13: ...n the lid is pulled downwards until it locks 2 The physical location of FA 20 Typically FA 20 is placed next to one of the meters that are to be logged The most convenient location is against a wall v...

Page 14: ...y sending FA 20 a SMS FA 20 with firmware 1 30 or later contains as minimum the following software drivers KMX handles various Multical with 3 wire data module i e Multical III 66C Compact 401 and 601...

Page 15: ...to terminal 10 in FA 20 Brown wire Reg pin 5 in Unigas is connected to terminal 11 in FA 20 It is recommended to connect FA 20 directly to the internal plug in Unigas and let the plug with the RPG co...

Page 16: ...with M bus L G WSD and WSF L G 2WR4 2WR5 and UH50 with G2 or G4 Sensus Mechanical water meter with M bus Hydrometer Sharkey with M bus and Infocal 5 with M bus ABB Type Delta with M bus Use Fa 20 conn...

Page 17: ...n communication with the GSM GPRS modem the big red LED Top right corner visible through the lid will after a few seconds flash quickly and stable to indicate errors Common log operation is stopped 9...

Page 18: ...will light constantly during the communication and in case of error the red LED will report the error by a 3 second long flash Note Automatic readout after power up Approximately 2 3 min after power...

Page 19: ...ed LED is ON for 3 sec Failure without any permanent influence on normal operation 1 A serial reading of a meter failed 2 Data communication with the main station failed 3 Brief power failure More aty...

Page 20: ...If there is no power error like in point 1 and the little green internal LED is turned off then it is properly an error in the GSM modem and the FA 20 should be taken down and sent to service If the...

Page 21: ...eadout from serial meters then you can test the communication between the FA 20 and serial meters by pushing the key After a keystroke the big green LED will flash once briefly per second by readout o...

Page 22: ...002000 Pulse counter stand for pulse input no 2 In 1 OFF 2 OFF Signal on digital input no 1 on off and no 2 on off In 3 OFF 4 OFF Signal on digital input no 3 on off and no 4 on off Out 1 OFF 2 OFF Re...

Page 23: ...nd for M1 Volume 839 Volume counter stand for M1 Mbus2 90012312 Serial no read from meter connected to M2 Energy 3552 25 Energy counter stand for M2 Volume 88243 88 Volume counter stand for M2 Multi 3...

Page 24: ...variants Above is the fully wired version with 4 pulses or digital S01 inputs 2 relay outputs and 2 x 0 4 20 mA inputs Below is a variant only with 4 pulses or digital inputs Relay outputs Max 27Vdc...

Page 25: ...Ds in the middle column shows pulses from pulse input 5 to 8 and the orange LEDs in the right column shows pulse inp Pulse input 9 to 12 in connector In the middle to the right NOTE Pulse input 1 and...

Page 26: ...cates the current status of the output Light in the LED means output is active closed loop Specification These are 2 electrically isolated optocoupler outputs Max applied voltage is 27Vdc open loop Ma...

Reviews: