![Cattron CANplus CP1000 Operation Manual Download Page 32](http://html.mh-extra.com/html/cattron/canplus-cp1000/canplus-cp1000_operation-manual_2574665032.webp)
CANplus CP1000
Control Panel Operation Manual
*Patent Pending
32
9M02-1000-A401-EN Revision G
6.8
Auto Battery Recharge
The CP1000 can be configured to monitor the battery and crank up the engine to recharge the battery once the
battery voltage falls to a configured level. To enable and configure this feature with Tech or Admin level access,
navigate to
Autostart
→
Auto Battery Recharge
•
Auto Battery Enabled
o
Off/On
•
Recharge Run Speed
o
The speed that the engine will run at during the recharging
•
Enable Delay (m)
o
How long the battery must be at or below the voltage threshold before the recharging is started
•
Recharge Time (m)
o
How long the engine runs to recharge the battery
•
Delay Between Recharge (m)
o
How long to wait between recharge cycles
•
Low Battery Threshold (V)
o
The battery voltage the battery must be at or below to start a recharge
6.9
Auto Antifreeze
The CP1000 can be configured to periodically run to prevent fluid in the system pipes from freezing. To enable
and configure this feature with Tech or Admin level access, navigate to
Autostart
→
Auto Antifreeze
•
Auto Antifreeze Enabled
o
Off/On
•
Antifreeze Run Speed
o
The speed that the engine or motor will run to prevent fluid from freezing
•
Antifreeze Delay (m)
o
How long to wait between antifreeze cycles
•
Antifreeze Run time (m)
o
How long the engine or motor will run to prevent fluid from freezing