Pressing the Dashboard-2 button again will cause the display to revert to the gauge page.
3.5
Active Alarms
When an active alarm is received, a flashing popup window is overlaid on the current screen. The popup
includes a plain language description in addition to the standard SPN/FMI (Suspect Parameter Number/Failure
Mode Indicator) pair defined by the SAE J1939 standard. Additionally, if enabled, the beeper sounds as an
audible cue.
Note:
Standard J1939 abbreviations are used for alarms, as follows:
MS = Most Severe
MOD = Moderately Severe
LS = Least Severe
3.6
Alarm List
The Alarm List is accessed by pressing any button while an alarm popup is displayed or by pressing any of the
first four buttons to show the button bar and then button 4. Alarms not yet acknowledged are shown in white text
on a red background, while acknowledged alarms are shown in white on black. The list also indicates when the
alarm occurred if engine hours are available. The most recent alarm is displayed at the top of the list. The list can
be scrolled using buttons 1 and 2 and alarms acknowledged by pressing button 3. The Alarm List can be closed
by pressing button 5 once the alarms are acknowledged.
An alarm indicator is displayed near the upper right corner of the display as long as alarms are active. The
indicator and alarm messages in the list are automatically removed when the alarm has not been received for a
few seconds.