end of season shut down
Make sure hopper and feed system are clear of all pellets.
Vacuum the interior of the hopper and spray with a silicone
protector to avoid any rusting in high humidity areas.
Clean out all fly ash from the exhaust venting system.
Vacuum stove interior and the ash pan. Thoroughly clean
the burn pot and lightly coat with a rust inhibitor such as
silicone or oil to prevent rusting. Remove exhaust motor
and clean the fly ash out of the exhaust duct. Clean the
radial blades of the exhaust fan.
Take the venting apart and clean out the fly ash, rinse
and let dry. Clean the glass, doors and outer cabinet so
that you are ready for the next heating season. Use of an
ash vacuum makes cleaning easier and faster.
troubleshooting & rePair
At Ardisam, we build quality and durability into the design
of our products; but no amount of careful design by us, and
careful maintenance by you, can guarantee a repair-free
life for your stove. Most repairs will be minor, and easily
fixed by following the suggestions in the troubleshooting
guide in this section.
The guide will help you pinpoint the causes of common
problems and identify remedies.
For more complicated repairs, you may want to rely on
your retailer, an authorized service center or Ardisam, Inc.
A parts catalog is included in this section.
We will always be glad to answer any questions you
have, or help you find suitable assistance. To order parts
or inquire about warranty, call or write us at the address
found below.
ordering rePlacement Parts
Parts can be obtained from the store where the stove was
purchased or direct from the factory. To order from the
factory- call, write or e-mail to:
ardisam, inc.
1160 eighth avenue,
cumberland, wisconsin 54829
1-800-345-6007
e-mail: [email protected]
Please include the following information with your
order:
1. Model number and serial number
2. Part description
3. Quantity
4. Part numbers
Warning
w h e n P e r f o r m i n g a n y i n t e r n a l
maintenance.
• movIng partS InSIde of the cabInet
may cause injury. do not oPerate unit
with Panels removed or oPen.
• hot partS. do not operate the unIt
with Panel oPen.
• rISK of electrIc ShocK. dISconnect
Power before servicing unit.
• In the event of component faIlure,
rePlace with the original factory
equiPment.
Caution
this is a minimum requirement for soot
and fly ash removal. ashes should
be Placed in a metal container with a
tight fitting lid. the container should
be Placed on a non-combustible
floor, well away from combustible
materials, Pending final disPosal.
if ashes are disPosed of by burial in
soil or otherwise locally disPersed,
they should be retained in the closed
container until all cinders are no
thoroughly cool.
Caution
do not oPerate stove with broken
glass.
do not slam the door shut.
do not strike glass.
do not use abrasive cleaners.
do not clean hot glass.
rePlace ceramic glass with factory
authorized rePlacement Parts only.
the clinker will remain hot for several
minutes after it is Pulled out of the
fire Pot.